Parameters affecting the determination of paraquat at silver rotating electrodes using differential pulse voltammetry

A. Farahi , S. Lahrich , M. Achak , L. El Gaini , M. Bakasse , M.A. El Mhammedi
{"title":"Parameters affecting the determination of paraquat at silver rotating electrodes using differential pulse voltammetry","authors":"A. Farahi ,&nbsp;S. Lahrich ,&nbsp;M. Achak ,&nbsp;L. El Gaini ,&nbsp;M. Bakasse ,&nbsp;M.A. El Mhammedi","doi":"10.1016/j.ancr.2014.05.001","DOIUrl":null,"url":null,"abstract":"<div><p>The electrochemical determination of aqueous paraquat PQ(II) by differential pulse voltammetry at a solid rotating silver electrode (RSE) is described. The aim of this work is to optimize all factors that can influence this determination. Potential wave forms, potential scan parameters and deposition time were examined for their effect on the paraquat peak shape and intensity. The best responses were obtained with differential pulse voltammetry in 0.1<!--> <!-->mol<!--> <!-->L<sup>−1</sup> Na<sub>2</sub>SO<sub>4</sub> as supporting electrolyte using amplitude 50<!--> <!-->mV, scan increment 5<!--> <!-->mV, deposition time 120<!--> <!-->s, frequency 50<!--> <!-->s<sup>−1</sup> and step amplitude 0.05<!--> <!-->V. Electrochemical and mechanical surface cleaning, aimed at removing the amount of paraquat deposited onto the silver surface, were necessary for obtaining a good performance of the electrode. Response linearity, repeatability, accuracy and detection limit were also evaluated. The obtained detection limits were 7.1<!--> <!-->×<!--> <!-->10<sup>−9</sup> <!-->mol<!--> <!-->L<sup>−1</sup> and 2.8<!--> <!-->×<!--> <!-->10<sup>−9</sup> <!-->mol<!--> <!-->L<sup>−1</sup> for peak 1 and peak 2 respectively. The relative standard deviation (RSD) was found to be 1.19% in 1.0<!--> <!-->×<!--> <!-->10<sup>−4</sup> <!-->mol<!--> <!-->L<sup>−1</sup> paraquat. The applicability of the RSE for PQ(II) determination in milk samples, without any sample pretreatment, was successfully demonstrated.</p></div>","PeriodicalId":7819,"journal":{"name":"Analytical Chemistry Research","volume":"1 ","pages":"Pages 16-21"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ancr.2014.05.001","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214181214000032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

The electrochemical determination of aqueous paraquat PQ(II) by differential pulse voltammetry at a solid rotating silver electrode (RSE) is described. The aim of this work is to optimize all factors that can influence this determination. Potential wave forms, potential scan parameters and deposition time were examined for their effect on the paraquat peak shape and intensity. The best responses were obtained with differential pulse voltammetry in 0.1 mol L−1 Na2SO4 as supporting electrolyte using amplitude 50 mV, scan increment 5 mV, deposition time 120 s, frequency 50 s−1 and step amplitude 0.05 V. Electrochemical and mechanical surface cleaning, aimed at removing the amount of paraquat deposited onto the silver surface, were necessary for obtaining a good performance of the electrode. Response linearity, repeatability, accuracy and detection limit were also evaluated. The obtained detection limits were 7.1 × 10−9 mol L−1 and 2.8 × 10−9 mol L−1 for peak 1 and peak 2 respectively. The relative standard deviation (RSD) was found to be 1.19% in 1.0 × 10−4 mol L−1 paraquat. The applicability of the RSE for PQ(II) determination in milk samples, without any sample pretreatment, was successfully demonstrated.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
影响银旋转电极差分脉冲伏安法测定百草枯的参数
介绍了在固体旋转银电极(RSE)上用微分脉冲伏安法测定水中百草枯PQ(II)的电化学方法。这项工作的目的是优化所有可能影响这一决定的因素。研究了电位波形、电位扫描参数和沉积时间对百草枯峰形状和强度的影响。采用差分脉冲伏安法,在0.1 mol L−1 Na2SO4为负载电解质时,在振幅为50 mV、扫描增量为5 mV、沉积时间为120 s、频率为50 s−1、阶跃振幅为0.05 V的条件下,获得了最佳响应。电化学和机械表面清洗旨在去除沉积在银表面的百草枯,这是获得良好电极性能所必需的。并对响应线性度、重复性、准确度和检出限进行了评价。峰1和峰2的检出限分别为7.1 × 10−9 mol L−1和2.8 × 10−9 mol L−1。在1.0 × 10−4 mol L−1百草枯条件下,相对标准偏差(RSD)为1.19%。成功地证明了RSE在牛奶样品中测定PQ(II)的适用性,无需任何样品预处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations Preparation and characterization of a novel Co(II) optode based on polymer inclusion membrane Structural identification and estimation of Rosuvastatin calcium related impurities in Rosuvastatin calcium tablet dosage form Comparative sensing of aldehyde and ammonia vapours on synthetic polypyrrole-Sn(IV)arsenotungstate nanocomposite cation exchange material Nano clay Ni/NiO nanocomposite new sorbent for separation and preconcentration dibenzothiophene from crude prior to UV–vis spectrophotometery determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1