{"title":"The short and one-year outcome of transcatheter Patent Ductus Arteriosus closure at Inkosi Albert Luthuli Central Hospital, Durban, South Africa: A Descriptive retrospective chart review","authors":"K. Koolash, E. Hoosen","doi":"10.24170/17-1-4020","DOIUrl":null,"url":null,"abstract":"Background: Transcatheter closure of patent ductus arteriosus is a common intervention worldwide. A review of the outcomes of patients undergoing this procedure was undertaken at a central hospital in Durban, South Africa. Methods: Retrospective observational descriptive study of the short ( 1 year) efficacy and safety of patients who underwent transcatheter closure of PDA from January 2010 - December 2015 at Inkosi Albert Luthuli Central Hospital (IALCH), Durban, KwaZulu-Natal. Results: Over the 5 years, 181 patients underwent cardiac catheterisation for PDA closure: 170 (93.9%) had successful percutaneous closure, and 11 (6.07%) required surgical ligation. Mean age was 30.2 ± 9.7 months, weight 11.2kg ± 3.6kg, PDA diameter on echocardiography was 3.64mm (SD ± 0.97mm), fluoroscopy time 13.66 minutes (SD ± 4.37min) and radiation dose 468.61 microGrays (SD ± 149.9microGrays). Devices used included the Amplatzer Duct Occluder (ADO) I, ADO II, ADO II AS, Cera, Occlutech, detachable coils and vascular plugs. Twenty-five patients (15%) had complications (6 major: 2 device embolisation, 1 blood loss and 3 pulse loss). Conclusion: Percutaneous PDA closure at IALCH, South Africa, had a comparable level of safety and efficacy to reports from other centres.","PeriodicalId":22462,"journal":{"name":"The Egyptian Heart Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Egyptian Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24170/17-1-4020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transcatheter closure of patent ductus arteriosus is a common intervention worldwide. A review of the outcomes of patients undergoing this procedure was undertaken at a central hospital in Durban, South Africa. Methods: Retrospective observational descriptive study of the short ( 1 year) efficacy and safety of patients who underwent transcatheter closure of PDA from January 2010 - December 2015 at Inkosi Albert Luthuli Central Hospital (IALCH), Durban, KwaZulu-Natal. Results: Over the 5 years, 181 patients underwent cardiac catheterisation for PDA closure: 170 (93.9%) had successful percutaneous closure, and 11 (6.07%) required surgical ligation. Mean age was 30.2 ± 9.7 months, weight 11.2kg ± 3.6kg, PDA diameter on echocardiography was 3.64mm (SD ± 0.97mm), fluoroscopy time 13.66 minutes (SD ± 4.37min) and radiation dose 468.61 microGrays (SD ± 149.9microGrays). Devices used included the Amplatzer Duct Occluder (ADO) I, ADO II, ADO II AS, Cera, Occlutech, detachable coils and vascular plugs. Twenty-five patients (15%) had complications (6 major: 2 device embolisation, 1 blood loss and 3 pulse loss). Conclusion: Percutaneous PDA closure at IALCH, South Africa, had a comparable level of safety and efficacy to reports from other centres.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
南非德班Inkosi Albert Luthuli中心医院经导管动脉导管未闭闭合的短期和一年结果:描述性回顾性图表回顾
背景:经导管关闭动脉导管未闭是世界范围内常见的介入治疗。在南非德班的一家中心医院对接受这一手术的患者的结果进行了审查。方法:回顾性观察性描述性研究2010年1月至2015年12月在夸祖鲁-纳塔尔省德班Inkosi Albert Luthuli中心医院(IALCH)行经导管关闭PDA患者的短期(1年)疗效和安全性。结果:5年内,181例患者行心导管闭锁术,其中170例(93.9%)成功经皮闭锁,11例(6.07%)需要手术结扎。平均年龄30.2±9.7个月,体重11.2kg±3.6kg,超声心动图PDA直径3.64mm (SD±0.97mm),透视时间13.66 min (SD±4.37min),放射剂量468.61 microgreays (SD±149.9 microgreays)。使用的设备包括Amplatzer导管闭塞器(ADO) I、ADO II、ADO II AS、Cera、Occlutech、可拆卸线圈和血管塞。25例(15%)患者出现并发症(主要6例:器械栓塞2例,失血1例,脉搏丧失3例)。结论:南非IALCH的经皮PDA闭合术与其他中心的报告相比具有相当的安全性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Excimer laser coronary angioplasty: a mini-narrative review of clinical outcomes Myxomatous cause of multiple intracranial aneurysms and cognitive decline: a case report Isolated diastolic hypertension and cardiovascular outcomes across different diagnostic guidelines: a systematic review and meta-analysis A rare differential diagnosis of aortic stenosis with a black aortic valve: A case report Safety and efficacy of early beta-blocker initiation in acute heart failure and cardiogenic shock: systematic review and meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1