Quantification of 3α-hydroxytibolone in human plasma by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS): Application in a bioequivalence study in healthy postmenopausal volunteers

Lucas Azevedo Portela , Tiago Luders Laurito , Beatrice Severino , Elisa Perissutti , Gustavo D. Mendes , Ronilson Agnaldo Moreno , Gilberto De Nucci
{"title":"Quantification of 3α-hydroxytibolone in human plasma by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS): Application in a bioequivalence study in healthy postmenopausal volunteers","authors":"Lucas Azevedo Portela ,&nbsp;Tiago Luders Laurito ,&nbsp;Beatrice Severino ,&nbsp;Elisa Perissutti ,&nbsp;Gustavo D. Mendes ,&nbsp;Ronilson Agnaldo Moreno ,&nbsp;Gilberto De Nucci","doi":"10.1016/j.ancr.2016.04.002","DOIUrl":null,"url":null,"abstract":"<div><p>A sensitive, specific and fast method to quantify 3α-hydroxytibolone in human plasma using deuterated 3α-hydroxytibolone (d5) as internal standard is described. The analyte and the internal standard were extracted from plasma (900 μL) by liquid-liquid extraction using ethyl ether/hexane (50/50, v/v) and ammonium hydroxide (50%). The extracts were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry without derivatization. Chromatography was performed isocratically on a Gemini-NX™ C<sub>18</sub> 5 μm (150 × 4.6 mm i. d.) column. The method had a chromatographic run time of 3.75 min and a linear calibration curve over the range 1–100 ng/mL. The limit of quantification validated was 1 ng/mL. This method was used to assess the bioequivalence between two different tibolone oral formulations: Livolon (1.25 mg tablet) provided by Biolab Sanus Farmacêutica (Brazil), as the test formulation, and Libiam™ (1.25 mg tablet) produced by Libbs Farmacêutica (Brazil), as the reference formulation. A single 3.75 mg dose of each formulation was administered to 46 postmenopausal female healthy volunteers. The study was conducted in an open, randomized, two-period crossover balanced design with a 2 week washout interval between the doses. The 90% confidence interval for C<sub>max</sub>, AUC<sub>(0-last)</sub> and AUC<sub>(0-inf)</sub> individual test/reference ratios were 97.48–111.51, 95.35–103.20 and 96.42–103.86, respectively. It is concluded that Livolon (1.25 mg tablet) is bioequivalent to Libiam™ (1.25 mg tablet), with regards to both rate and extent of absorption.</p></div>","PeriodicalId":7819,"journal":{"name":"Analytical Chemistry Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ancr.2016.04.002","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221418121630009X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A sensitive, specific and fast method to quantify 3α-hydroxytibolone in human plasma using deuterated 3α-hydroxytibolone (d5) as internal standard is described. The analyte and the internal standard were extracted from plasma (900 μL) by liquid-liquid extraction using ethyl ether/hexane (50/50, v/v) and ammonium hydroxide (50%). The extracts were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry without derivatization. Chromatography was performed isocratically on a Gemini-NX™ C18 5 μm (150 × 4.6 mm i. d.) column. The method had a chromatographic run time of 3.75 min and a linear calibration curve over the range 1–100 ng/mL. The limit of quantification validated was 1 ng/mL. This method was used to assess the bioequivalence between two different tibolone oral formulations: Livolon (1.25 mg tablet) provided by Biolab Sanus Farmacêutica (Brazil), as the test formulation, and Libiam™ (1.25 mg tablet) produced by Libbs Farmacêutica (Brazil), as the reference formulation. A single 3.75 mg dose of each formulation was administered to 46 postmenopausal female healthy volunteers. The study was conducted in an open, randomized, two-period crossover balanced design with a 2 week washout interval between the doses. The 90% confidence interval for Cmax, AUC(0-last) and AUC(0-inf) individual test/reference ratios were 97.48–111.51, 95.35–103.20 and 96.42–103.86, respectively. It is concluded that Livolon (1.25 mg tablet) is bioequivalent to Libiam™ (1.25 mg tablet), with regards to both rate and extent of absorption.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高效液相色谱-电喷雾电离串联质谱法(HPLC-ESI-MS/MS)定量测定人血浆中3α-羟基替布洛酮:在健康绝经后志愿者生物等效性研究中的应用
建立了以氘化3α-羟基替布洛酮(d5)为内标,快速、灵敏、特异地定量人血浆中3α-羟基替布洛酮的方法。采用乙醚/己烷(50/50,v/v)和氢氧化铵(50%)液-液萃取法,从血浆(900 μL)中提取分析物和内标物。采用高效液相色谱-电喷雾电离串联质谱法对提取物进行分析,无衍生化反应。色谱柱为Gemini-NX™C18 5 μm (150 × 4.6 mm直径)。该方法色谱运行时间为3.75 min,在1 ~ 100 ng/mL范围内具有线性校准曲线。定量验证限为1 ng/mL。采用该方法评价两种不同的替博龙口服制剂的生物等效性:以巴西Biolab Sanus Farmacêutica公司生产的Livolon (1.25 mg片剂)为试验制剂,以巴西Libbs Farmacêutica公司生产的Libiam™(1.25 mg片剂)为参比制剂。对46名绝经后健康女性志愿者分别给予每种配方3.75 mg的单剂量。该研究采用开放、随机、两期交叉平衡设计,两剂之间有2周的洗脱间隔。Cmax、AUC(0-last)和AUC(0-inf)个体试验/参考比的90%置信区间分别为97.48 ~ 111.51、95.35 ~ 103.20和96.42 ~ 103.86。结论是Livolon (1.25 mg片剂)与Libiam™(1.25 mg片剂)在吸收率和吸收率方面具有生物等效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations Preparation and characterization of a novel Co(II) optode based on polymer inclusion membrane Structural identification and estimation of Rosuvastatin calcium related impurities in Rosuvastatin calcium tablet dosage form Comparative sensing of aldehyde and ammonia vapours on synthetic polypyrrole-Sn(IV)arsenotungstate nanocomposite cation exchange material Nano clay Ni/NiO nanocomposite new sorbent for separation and preconcentration dibenzothiophene from crude prior to UV–vis spectrophotometery determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1