Investigation of Earthquake Significant Duration on the Seismic Performance of Adjacent Steel Structures in Near-Source

Mansoureh Rezaee Manesh, S. Fattahi, H. Saffari
{"title":"Investigation of Earthquake Significant Duration on the Seismic Performance of Adjacent Steel Structures in Near-Source","authors":"Mansoureh Rezaee Manesh, S. Fattahi, H. Saffari","doi":"10.22075/JRCE.2020.20373.1410","DOIUrl":null,"url":null,"abstract":"According to the recent Earthquake records, the earthquake duration is longer in some areas, resulting into more structural damage. One of the important factors in reducing earthquake damages is the separation gap between two adjacent structures. This case study investigated the effect of significant duration of the earthquake on two adjacent steel moment-resisting structures with different heights and near to active fault. The pounding between pairs of three 3, 6 and 9-story steel moment frames was evaluated using a nonlinear time history analysis method considering the reduced stiffness and strength. The results showed that for the intended type 3-soil, the risk of pounding and collapse amplification among the 3- and 6-story buildings are higher than others. This is due to the necessity of the Iranian standard 2800 to calculate the separation gap by the nonlinear methods for the buildings with height more than 8 stories. Also, the analysis of the significant duration of the applied earthquakes demonstrated that this parameter is a determining and effective factor in the pounding of structures, especially the adjacent buildings with defferent heights. It is noteworthy all of the analysis was done by 9 earthquake records. This study recommended using the nonlinear method to calculate separation gap while designing two adjacent steel moment-resisting structures with different heights in the near-field area and on the soft soil.","PeriodicalId":52415,"journal":{"name":"Journal of Rehabilitation in Civil Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation in Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22075/JRCE.2020.20373.1410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

Abstract

According to the recent Earthquake records, the earthquake duration is longer in some areas, resulting into more structural damage. One of the important factors in reducing earthquake damages is the separation gap between two adjacent structures. This case study investigated the effect of significant duration of the earthquake on two adjacent steel moment-resisting structures with different heights and near to active fault. The pounding between pairs of three 3, 6 and 9-story steel moment frames was evaluated using a nonlinear time history analysis method considering the reduced stiffness and strength. The results showed that for the intended type 3-soil, the risk of pounding and collapse amplification among the 3- and 6-story buildings are higher than others. This is due to the necessity of the Iranian standard 2800 to calculate the separation gap by the nonlinear methods for the buildings with height more than 8 stories. Also, the analysis of the significant duration of the applied earthquakes demonstrated that this parameter is a determining and effective factor in the pounding of structures, especially the adjacent buildings with defferent heights. It is noteworthy all of the analysis was done by 9 earthquake records. This study recommended using the nonlinear method to calculate separation gap while designing two adjacent steel moment-resisting structures with different heights in the near-field area and on the soft soil.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
地震显著持续时间对近震源相邻钢结构抗震性能的影响研究
根据最近的地震记录,一些地区的地震持续时间更长,导致更多的结构破坏。减少地震破坏的重要因素之一是相邻结构之间的间距。本案例研究了地震显著持续时间对相邻两个不同高度且靠近活动断层的钢抗弯矩结构的影响。采用非线性时程分析方法对3个3层、6层和9层弯矩框架对间的冲击进行了分析。结果表明:对于3型土,3层和6层建筑的冲击和倒塌放大风险高于其他类型;这是由于伊朗标准2800要求用非线性方法计算8层以上建筑的隔距间隙。同时,对应用地震的显著持续时间的分析表明,该参数是结构,特别是相邻不同高度的建筑物的冲击的决定性和有效因素。值得注意的是,所有的分析都是根据9次地震记录完成的。本研究建议在近场区和软土地基上设计相邻两个不同高度的钢抗矩结构时,采用非线性方法计算分离间隙。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Rehabilitation in Civil Engineering
Journal of Rehabilitation in Civil Engineering Engineering-Building and Construction
CiteScore
1.60
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Damage Sensitive-Stories of RC and Steel Frames under Critical Mainshock-Aftershock Ground Motions Evaluation of Intermediate Reinforced Concrete Moment Frame subjected to Truck collision Damage Detection in Prestressed Concrete Slabs Using Wavelet Analysis of Vibration Responses in the Time Domain Rehabilitation of Corroded Reinforced Concrete Elements by Rebar Replacement Risk assessment and challenges faced in repairs and rehabilitation of dilapidated buildings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1