Organisation Et Depouillement Automatique Des Mesures Dans Les Deux Soufflerier a Arc De L'Onera

M. Delattre
{"title":"Organisation Et Depouillement Automatique Des Mesures Dans Les Deux Soufflerier a Arc De L'Onera","authors":"M. Delattre","doi":"10.1109/TA.1965.4319752","DOIUrl":null,"url":null,"abstract":"Several unique conditions are imposed upon measurements made in ONERA hotshot wind tunnels: the duration of flow; the environmental conditions; the circumstances under which the tunnels are used. Flow durations between 40 and 100 milliseconds are produced, and this imposes demands upon transducer performance. Instantaneous power consumed by the tunnels is of the order of 200 megavolt-amperes, and this places the transducers and portions of the readout system in an electrical environment wherein elaborate shielding precautions are required. The contract arrangement under which the tunnels are operated necessitates their use in testing for an optimum number of runs within a half-day of operation, and this necessitates the use of highly automated readout apparatus. This paper describes the solutions to these and other hotshot instrumentation problems. Methods of measurement and readout of pressure, forces, and rates of heat transfer are discussed, and systems for calibration are presented. Many elements of the calibration and readout processes have been made largely automatic. Errors contained among data representing the measurement of forces are sufficiently small as to be considered negligible in the face of minor uncertainties in readout constants. Measurement of pressures is conducted to an overall accuracy (including calibration and readout) of 2.5%. Heat transfer calibrations of 5-10% accuracy are imposed, and overall accuracy of heat transfer data ranges between 15 and 20 percent.","PeriodicalId":13050,"journal":{"name":"IEEE Transactions on Aerospace","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1965-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Aerospace","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TA.1965.4319752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Several unique conditions are imposed upon measurements made in ONERA hotshot wind tunnels: the duration of flow; the environmental conditions; the circumstances under which the tunnels are used. Flow durations between 40 and 100 milliseconds are produced, and this imposes demands upon transducer performance. Instantaneous power consumed by the tunnels is of the order of 200 megavolt-amperes, and this places the transducers and portions of the readout system in an electrical environment wherein elaborate shielding precautions are required. The contract arrangement under which the tunnels are operated necessitates their use in testing for an optimum number of runs within a half-day of operation, and this necessitates the use of highly automated readout apparatus. This paper describes the solutions to these and other hotshot instrumentation problems. Methods of measurement and readout of pressure, forces, and rates of heat transfer are discussed, and systems for calibration are presented. Many elements of the calibration and readout processes have been made largely automatic. Errors contained among data representing the measurement of forces are sufficiently small as to be considered negligible in the face of minor uncertainties in readout constants. Measurement of pressures is conducted to an overall accuracy (including calibration and readout) of 2.5%. Heat transfer calibrations of 5-10% accuracy are imposed, and overall accuracy of heat transfer data ranges between 15 and 20 percent.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在onera的两个电弧鼓风机中组织和自动分析测量结果
在ONERA热点风洞中进行的测量施加了几个独特的条件:流动持续时间;环境条件;隧道的使用情况。流量持续时间在40到100毫秒之间,这对换能器的性能提出了要求。隧道所消耗的瞬时功率约为200兆伏安,这将传感器和读出系统的部分置于需要精心防护的电气环境中。根据隧道的合同安排,隧道必须在半天的运行时间内进行测试,以获得最佳的运行次数,这就需要使用高度自动化的读数装置。本文介绍了解决这些和其他热点仪表问题的方法。讨论了压力、力和传热速率的测量和读出方法,并介绍了校准系统。校准和读出过程的许多要素已在很大程度上实现了自动化。表示力测量的数据中包含的误差足够小,在读出常数的微小不确定性面前可以忽略不计。压力测量的整体精度(包括校准和读数)为2.5%。传热校准的精度为5-10%,传热数据的总体精度在15 - 20%之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modelling of Radiation Effects in Semiconductor Devices and Circuits Dynamic Response of an Asymmetrical Spinning Space Station A Digital System for the Acquisition and Analysis of Random Data Precisely Controlled 3-Phase Squirrel Cage Induction Motor Drives for Aerospace Applications Heat-Shield Ablation and Sublimation Determinations through Radioisotope Techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1