Fibrin Glue in Temporal Clear Corneal Tunnel Incision

Burkhard Dick, Thomas Kohnen, Volker Hessemer
{"title":"Fibrin Glue in Temporal Clear Corneal Tunnel Incision","authors":"Burkhard Dick,&nbsp;Thomas Kohnen,&nbsp;Volker Hessemer","doi":"10.1016/S0955-3681(13)80039-1","DOIUrl":null,"url":null,"abstract":"<div><p><strong>OBJECTIVE:</strong> While 3.5 mm clear corneal incisions for the implantation of foldable silicone lenses are commonly accepted, longer incisions for PMMA-IOL implantation are associated with a possibly higher risk of infection and less self-sealing properties. <strong>DESIGN:</strong> It was intended to reinforce the 5 mm clear corneal tunnel incision after phacoemulsification and IOL-implantation with fibrin adhesive. <strong>SETTING:</strong> Department of Ophthalmology, University of Giessen, Germany. <strong>METHODS:</strong> Upon simultaneous mixing of fibrinogen complex and thrombin, the final stages of the coagulation cascade are mimicked after application of fibrin glue, resulting in formation of a fibrin clot. <strong>MAIN OUTCOME:</strong> The sealant consolidated and adhered to the site of corneal application. The present case demonstrated that fibrin glue is efficacious in watertight wound closure of 5 mm clear corneal incision and provides good support for corneal healing. Only minimal surgically-induced with-the-rule astigmatism was observed. <strong>CONCLUSION:</strong> In the future, this technique of corneal wound closure might develop as an alternative to singlesuture wound closure after small incision cataract extraction.</p></div>","PeriodicalId":100500,"journal":{"name":"European Journal of Implant and Refractive Surgery","volume":"7 4","pages":"Pages 224-228"},"PeriodicalIF":0.0000,"publicationDate":"1995-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0955-3681(13)80039-1","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Implant and Refractive Surgery","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0955368113800391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

OBJECTIVE: While 3.5 mm clear corneal incisions for the implantation of foldable silicone lenses are commonly accepted, longer incisions for PMMA-IOL implantation are associated with a possibly higher risk of infection and less self-sealing properties. DESIGN: It was intended to reinforce the 5 mm clear corneal tunnel incision after phacoemulsification and IOL-implantation with fibrin adhesive. SETTING: Department of Ophthalmology, University of Giessen, Germany. METHODS: Upon simultaneous mixing of fibrinogen complex and thrombin, the final stages of the coagulation cascade are mimicked after application of fibrin glue, resulting in formation of a fibrin clot. MAIN OUTCOME: The sealant consolidated and adhered to the site of corneal application. The present case demonstrated that fibrin glue is efficacious in watertight wound closure of 5 mm clear corneal incision and provides good support for corneal healing. Only minimal surgically-induced with-the-rule astigmatism was observed. CONCLUSION: In the future, this technique of corneal wound closure might develop as an alternative to singlesuture wound closure after small incision cataract extraction.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
纤维蛋白胶在颞透明角膜隧道切口中的应用
目的:虽然3.5 mm透明角膜切口用于可折叠硅胶晶体植入术是普遍接受的,但较长的切口用于PMMA-IOL植入术可能具有较高的感染风险和较差的自密封性。设计:用纤维蛋白粘接剂加固超声乳化人工晶状体植入术后5 mm透明角膜隧道切口。单位:德国吉森大学眼科。方法:同时混合纤维蛋白原复合物和凝血酶,在应用纤维蛋白胶后模拟凝血级联的最后阶段,导致纤维蛋白凝块的形成。主要结果:密封胶在角膜应用部位得到巩固和粘附。本病例证明纤维蛋白胶在5mm透明角膜切口的水密缝合中效果良好,为角膜愈合提供了良好的支撑。仅观察到最小的手术诱导的带尺散光。结论:在未来,这种角膜创面闭合技术可能成为小切口白内障摘除术后单缝合线创面闭合的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Subject Index Author Index Editorial Scleral Fixation Re-examined by Ultrasound Biomicroscopy Corneal Topography using a New Moiré Image-based System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1