Effect of different chlorhexidine application times on microtensile bond strength to dentin in Class I cavities

H. Kang, Ho-Jin Moon, D. Shin
{"title":"Effect of different chlorhexidine application times on microtensile bond strength to dentin in Class I cavities","authors":"H. Kang, Ho-Jin Moon, D. Shin","doi":"10.5395/RDE.2012.37.1.9","DOIUrl":null,"url":null,"abstract":"Objectives: This study evaluated the effect of 2% chlorhexidine digluconate (CHX) with different application times on microtensile bonds strength (MTBS) to dentin in class I cavities and intended to search for ideal application time for a simplified bonding protocol. Materials and Methods: Flat dentinal surfaces with class I cavities () in 40 molar teeth were bonded with etch-and-rinse adhesive system, Adper Single Bond 2 (3M ESPE) after: (1) etching only as a control group; (2) etching + CHX 5 sec + rinsing; (3) etching + CHX 15 sec + rinsing; (4) etching + CHX 30 sec + rinsing; and (5) etching + CHX 60 sec + rinsing. Resin composite was builtup with Z-250 (3M ESPE) using a bulk method and polymerized for 40 sec. For each condition, half of the specimens were immediately submitted to MTBS test and the rest of them were assigned to thermocycling of 10,000 cycles between and before testing. The data were analyzed using two-way ANOVA, at a significance level of 95%. Results: There was no significant difference in bond strength between CHX pretreated group and control group at the immediate testing period. After thermocycling, all groups showed reduced bond strength irrespective of the CHX use. However, groups treated with CHX maintained significantly higher MTBS than control group (p","PeriodicalId":21126,"journal":{"name":"Restorative Dentistry and Endodontics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restorative Dentistry and Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5395/RDE.2012.37.1.9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Objectives: This study evaluated the effect of 2% chlorhexidine digluconate (CHX) with different application times on microtensile bonds strength (MTBS) to dentin in class I cavities and intended to search for ideal application time for a simplified bonding protocol. Materials and Methods: Flat dentinal surfaces with class I cavities () in 40 molar teeth were bonded with etch-and-rinse adhesive system, Adper Single Bond 2 (3M ESPE) after: (1) etching only as a control group; (2) etching + CHX 5 sec + rinsing; (3) etching + CHX 15 sec + rinsing; (4) etching + CHX 30 sec + rinsing; and (5) etching + CHX 60 sec + rinsing. Resin composite was builtup with Z-250 (3M ESPE) using a bulk method and polymerized for 40 sec. For each condition, half of the specimens were immediately submitted to MTBS test and the rest of them were assigned to thermocycling of 10,000 cycles between and before testing. The data were analyzed using two-way ANOVA, at a significance level of 95%. Results: There was no significant difference in bond strength between CHX pretreated group and control group at the immediate testing period. After thermocycling, all groups showed reduced bond strength irrespective of the CHX use. However, groups treated with CHX maintained significantly higher MTBS than control group (p
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同氯己定应用次数对ⅰ类牙本质微拉伸结合强度的影响
目的:本研究评价了2%二光酸氯己定(CHX)不同应用时间对I类牙本质微拉伸键合强度(MTBS)的影响,旨在为简化的键合方案寻找理想的应用时间。材料与方法:对40颗磨牙进行I类牙槽()的平面牙质面粘接,采用蚀刻-冲洗胶粘剂系统,Adper Single Bond 2 (3M ESPE)进行粘接:(1)仅作为对照组进行蚀刻;(2)蚀刻+ CHX 5秒+冲洗;(3)蚀刻+ CHX 15秒+冲洗;(4)蚀刻+ CHX 30秒+冲洗;(5)蚀刻+ CHX 60秒+冲洗。树脂复合材料用Z-250 (3M ESPE)用散装法构建,并聚合40秒。每种条件下,一半的样品立即提交给MTBS测试,其余样品在测试之间和测试前进行10,000次热循环。数据分析采用双向方差分析,显著性水平为95%。结果:CHX预处理组与对照组在直接测试期的粘结强度无显著差异。热循环后,与CHX的使用无关,所有组的结合强度都有所降低。然而,CHX治疗组的MTBS明显高于对照组(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of at-home bleaching protocol with application on different surfaces: bleaching efficacy and hydrogen peroxide permeability Ingestion and surgical retrieval of an endodontic file: a case report Does minimally invasive canal preparation provide higher fracture resistance of endodontically treated teeth? A systematic review of in vitro studies Effect of dentin roughening and type of composite material on the restoration of non-carious cervical lesions: an in vivo study with 18 months of follow-up Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1