{"title":"Contrast-Enhanced Renal MRA","authors":"Anil N. Shetty, Kostaki G. Bis","doi":"10.1002/0471142719.mia2801s11","DOIUrl":null,"url":null,"abstract":"<p>The rapid growth of magnetic resonance imaging systems with enhanced gradient systems together with improved pulse sequences has improved the ability to image blood vessels with a spatial and temporal resolution similar to conventional X-ray angiography. With patients who cannot undergo X-ray angiography because they are contraindicated for iodinated contrast agents (having a creatinine level > 2.0), MRA (magnetic resonance angiography) has proven to be the modality of choice. Since the first demonstration of such contrast-enhanced studies in the abdominal aorta, there have been continual improvements in methods due to improved hardware/software capabilities. This unit presents the MR protocols to image vascular morphology using contrast-enhanced 3-D-MRA techniques. The pulse sequences described herein are based on the authors' experience with a Siemens 1.5 T Vision and 1.5 T Sonata scanners, but are expected to be equally applicable to machines from other manufacturers.</p>","PeriodicalId":100347,"journal":{"name":"Current Protocols in Magnetic Resonance Imaging","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2004-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/0471142719.mia2801s11","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Protocols in Magnetic Resonance Imaging","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/0471142719.mia2801s11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The rapid growth of magnetic resonance imaging systems with enhanced gradient systems together with improved pulse sequences has improved the ability to image blood vessels with a spatial and temporal resolution similar to conventional X-ray angiography. With patients who cannot undergo X-ray angiography because they are contraindicated for iodinated contrast agents (having a creatinine level > 2.0), MRA (magnetic resonance angiography) has proven to be the modality of choice. Since the first demonstration of such contrast-enhanced studies in the abdominal aorta, there have been continual improvements in methods due to improved hardware/software capabilities. This unit presents the MR protocols to image vascular morphology using contrast-enhanced 3-D-MRA techniques. The pulse sequences described herein are based on the authors' experience with a Siemens 1.5 T Vision and 1.5 T Sonata scanners, but are expected to be equally applicable to machines from other manufacturers.
磁共振成像系统的快速发展,增强了梯度系统和改进的脉冲序列,提高了血管成像的空间和时间分辨率,类似于传统的x射线血管造影。不能接受x线血管造影的患者,因为他们禁忌使用碘造影剂(有肌酐水平>2.0), MRA(磁共振血管造影)已被证明是选择的模式。自从第一次在腹主动脉中进行这种对比增强研究以来,由于硬件/软件能力的提高,方法不断改进。本单元提出了磁共振成像协议血管形态使用对比增强的3-D-MRA技术。本文描述的脉冲序列是基于作者使用西门子1.5 T Vision和1.5 T Sonata扫描仪的经验,但预计同样适用于其他制造商的机器。