R. Ravindran, J. Carter, Asit Kumar, Florin Capatana, I. Khan, M. Adlan, L. Premawardhana
{"title":"Pre-test Cortisol Levels in Predicting Short Synacthen Test Outcome: A Retrospective Analysis","authors":"R. Ravindran, J. Carter, Asit Kumar, Florin Capatana, I. Khan, M. Adlan, L. Premawardhana","doi":"10.1177/11795514221093316","DOIUrl":null,"url":null,"abstract":"Objective: Short Synacthen tests (SSTs) are expensive, dependent on Synacthen availability, and need supervision. To reduce SST testing, we examined the utility of pre-test cortisol (Cort0) and related parameters in predicting outcome. Design and Measurements: We retrospectively examined the following in all SSTs; (i) Cort0 (ii) indications (iii) and time and place of testing. Receiver operated characteristic (ROC) curves were devised for Cort0 to obtain the best cut-off for outcome prediction in those who had SSTs between 8 and 10 am (Group 1) and at other times (Group 2). Results: Of 506 SSTs, 13 were unsuitable for analysis. 111/493 SSTs (22.5%) were abnormal. (1) ROC curves predicted – (a) SST failure with 100% specificity when Cort0 was ⩽124 nmol/L (Group 1), or ⩽47 (Group 2); (b) a normal SST with 100% sensitivity when Cort0 ⩾314 nmol/L (Group 1) and ⩾323 nmol/L (Group 2). (2) There was significant correlation between Cort0 and 30-minute cortisol (rs = 0.65-0.78, P < .001). (3) Median Cort0 was lower in those who failed SSTs compared to those who passed (147 vs 298 nmol/L respectively, P < .001). (4) SST failure was commoner in Group 1 vs 2 (P = .001). (5) There was no difference in outcome between out-patient and inpatient SSTs. (6) SST failure was most common for ‘steroid related’ indications (39.6%, P < .001). Conclusions: This study indicates that (1) Cort0 ⩾ 323 (Group1) and ⩾314 nmol/L (Group 2) predicted a normal SST with 100% sensitivity; (2) Using these cut offs 141/493 (28.6%) tests may have been avoided; (3) supporting evidence should be considered in those with a lower pre-test predictability of failure.","PeriodicalId":44715,"journal":{"name":"Clinical Medicine Insights-Endocrinology and Diabetes","volume":"4 1","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Medicine Insights-Endocrinology and Diabetes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/11795514221093316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 1
Abstract
Objective: Short Synacthen tests (SSTs) are expensive, dependent on Synacthen availability, and need supervision. To reduce SST testing, we examined the utility of pre-test cortisol (Cort0) and related parameters in predicting outcome. Design and Measurements: We retrospectively examined the following in all SSTs; (i) Cort0 (ii) indications (iii) and time and place of testing. Receiver operated characteristic (ROC) curves were devised for Cort0 to obtain the best cut-off for outcome prediction in those who had SSTs between 8 and 10 am (Group 1) and at other times (Group 2). Results: Of 506 SSTs, 13 were unsuitable for analysis. 111/493 SSTs (22.5%) were abnormal. (1) ROC curves predicted – (a) SST failure with 100% specificity when Cort0 was ⩽124 nmol/L (Group 1), or ⩽47 (Group 2); (b) a normal SST with 100% sensitivity when Cort0 ⩾314 nmol/L (Group 1) and ⩾323 nmol/L (Group 2). (2) There was significant correlation between Cort0 and 30-minute cortisol (rs = 0.65-0.78, P < .001). (3) Median Cort0 was lower in those who failed SSTs compared to those who passed (147 vs 298 nmol/L respectively, P < .001). (4) SST failure was commoner in Group 1 vs 2 (P = .001). (5) There was no difference in outcome between out-patient and inpatient SSTs. (6) SST failure was most common for ‘steroid related’ indications (39.6%, P < .001). Conclusions: This study indicates that (1) Cort0 ⩾ 323 (Group1) and ⩾314 nmol/L (Group 2) predicted a normal SST with 100% sensitivity; (2) Using these cut offs 141/493 (28.6%) tests may have been avoided; (3) supporting evidence should be considered in those with a lower pre-test predictability of failure.