{"title":"Clinical Evaluation of a Novel Stool Antigen Test Using Bioluminescent Enzyme Immunoassay for Detecting Helicobacter pylori","authors":"T. Kakiuchi, M. Matsuo, Y. Sakata, K. Fujimoto","doi":"10.1155/2022/5571542","DOIUrl":null,"url":null,"abstract":"Background BLEIA ™ “EIKEN” Helicobacter pylori antigen (B[EIA]) is based on the bioluminescent enzyme immunoassay (BLEIA) method that was newly developed with high sensitivity in detecting Helicobacter pylori (H. pylori) antigen in feces. Methods In the project for H. pylori screening and treatment in Saga Prefecture in 2019, 141 students received the stool H. pylori antigen test as a secondary test. For 141 students, a comparative test was conducted between B (EIA) and extracorporeal diagnostic agents that were marketed in Japan as of 2019. The detection performance of H. pylori ATCC43504 standard strain and H. pylori antigen in commercial human fecal specimens were conducted. Results The comparison of B (EIA) with Quick Chaser TMH. pylori (Q [IC]) revealed positive and negative concordance ratios of B (EIA) to Q (IC) of 100.0% (110/110) and 71.0% (22/31), respectively. A comparative test was conducted between B (EIA) and extracorporeal diagnostic agents that were marketed in Japan as of 2019, and B (EIA) was most sensitive on “detecting H. pylori antigen of ATCC43504 standard strain” and “detecting H. pylori antigen in commercial human fecal specimens,” compared with other kits. Nine dissociated specimens that were negative for Q (IC) and positive for B (EIA) were confirmed. The measured value of B (EIA) in the dissociation samples were 1.3–87.4 cutoff index in the range that can be evaluated as negative by other fecal H. pylori antigen test kits, all the dissociation samples were H. pylori antigen-positive cases, and finally the cause of result divergence was presumed as false negative due to insufficient sensitivity of Q (IC). Conclusion B (EIA) that is based on the BLEIA method, which applies firefly luciferase luminescence, is more sensitive than stool antigen test kits that are currently marketed in Japan and is very useful in diagnosing H. pylori infection, especially in situations where noninvasive tests are preferred, such as in children.","PeriodicalId":48755,"journal":{"name":"Canadian Journal of Gastroenterology and Hepatology","volume":"4 1","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2022-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Gastroenterology and Hepatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2022/5571542","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4
Abstract
Background BLEIA ™ “EIKEN” Helicobacter pylori antigen (B[EIA]) is based on the bioluminescent enzyme immunoassay (BLEIA) method that was newly developed with high sensitivity in detecting Helicobacter pylori (H. pylori) antigen in feces. Methods In the project for H. pylori screening and treatment in Saga Prefecture in 2019, 141 students received the stool H. pylori antigen test as a secondary test. For 141 students, a comparative test was conducted between B (EIA) and extracorporeal diagnostic agents that were marketed in Japan as of 2019. The detection performance of H. pylori ATCC43504 standard strain and H. pylori antigen in commercial human fecal specimens were conducted. Results The comparison of B (EIA) with Quick Chaser TMH. pylori (Q [IC]) revealed positive and negative concordance ratios of B (EIA) to Q (IC) of 100.0% (110/110) and 71.0% (22/31), respectively. A comparative test was conducted between B (EIA) and extracorporeal diagnostic agents that were marketed in Japan as of 2019, and B (EIA) was most sensitive on “detecting H. pylori antigen of ATCC43504 standard strain” and “detecting H. pylori antigen in commercial human fecal specimens,” compared with other kits. Nine dissociated specimens that were negative for Q (IC) and positive for B (EIA) were confirmed. The measured value of B (EIA) in the dissociation samples were 1.3–87.4 cutoff index in the range that can be evaluated as negative by other fecal H. pylori antigen test kits, all the dissociation samples were H. pylori antigen-positive cases, and finally the cause of result divergence was presumed as false negative due to insufficient sensitivity of Q (IC). Conclusion B (EIA) that is based on the BLEIA method, which applies firefly luciferase luminescence, is more sensitive than stool antigen test kits that are currently marketed in Japan and is very useful in diagnosing H. pylori infection, especially in situations where noninvasive tests are preferred, such as in children.
期刊介绍:
Canadian Journal of Gastroenterology and Hepatology is a peer-reviewed, open access journal that publishes original research articles, review articles, and clinical studies in all areas of gastroenterology and liver disease - medicine and surgery.
The Canadian Journal of Gastroenterology and Hepatology is sponsored by the Canadian Association of Gastroenterology and the Canadian Association for the Study of the Liver.