Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse

A. Rasheed, J. W. Lee, H. Kim, H. W. Lee
{"title":"Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse","authors":"A. Rasheed, J. W. Lee, H. Kim, H. W. Lee","doi":"10.12791/ksbec.2019.28.3.225","DOIUrl":null,"url":null,"abstract":"In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to 9.6oC depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to 0.49 min-1. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of 3.2oC and a maximum ventilation rate of 0.49 min-1.","PeriodicalId":20654,"journal":{"name":"Protected horticulture and Plant Factory","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Protected horticulture and Plant Factory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12791/ksbec.2019.28.3.225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to 9.6oC depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to 0.49 min-1. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of 3.2oC and a maximum ventilation rate of 0.49 min-1.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同顶板通风口设计对单跨塑料大棚自然通风效果的影响
在夏季,当温室内空气温度高于最佳水平时,通常采用自然通风来降低温室内的温度。温室的形状、通风设计和位置对自然通风的有效性起着至关重要的作用。本研究采用计算流体力学(CFD)方法研究了不同顶板通风口设计及侧通风口对浮力驱动自然通风的影响。采用boussinesq假设对整个计算域的浮力效应进行模拟。采用RNG K-epsilon湍流模型,采用离散源(DO)辐射模型进行太阳射线追踪,模拟太阳辐射的影响。利用实验得到的温室内部温度对CFD模型进行了验证,实验结果与计算结果吻合较好。此外,采用该模型比较了7种不同屋顶通风口设计的温室内部温度和通风量。结果表明,不同的屋顶通风口类型对温室内外温差的影响在3.2 ~ 9.6℃之间。通风量在0.33 ~ 0.49 min-1之间。研究结果表明,锥形屋面通风的室内外温差最小为3.2oC,最大通风量为0.49 min-1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Seeding, seedling production and transplanting Biological factor management Micro- and mini-PFALs for improving the quality of life in urban areas Physical environmental factors and their properties Role of the plant factory with artificial lighting (PFAL) in urban areas
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1