Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength.

Masato Ogawa, Tsuyoshi Matsumoto, Risa Harada, Ryo Yoshikawa, Yuya Ueda, Daiki Takamiya, Yoshitada Sakai
{"title":"Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength.","authors":"Masato Ogawa,&nbsp;Tsuyoshi Matsumoto,&nbsp;Risa Harada,&nbsp;Ryo Yoshikawa,&nbsp;Yuya Ueda,&nbsp;Daiki Takamiya,&nbsp;Yoshitada Sakai","doi":"10.2490/prm.20230008","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment.</p><p><strong>Methods: </strong>The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference.</p><p><strong>Results: </strong>The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant.</p><p><strong>Conclusions: </strong>Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.</p>","PeriodicalId":74584,"journal":{"name":"Progress in rehabilitation medicine","volume":"8 ","pages":"20230008"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b7/18/prm-8-20230008.PMC9998244.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in rehabilitation medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2490/prm.20230008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Objectives: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment.

Methods: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference.

Results: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant.

Conclusions: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声测量股四头肌肌肉厚度的可靠性和有效性:与肌肉质量和力量的比较。
目的:使用超声测量骨骼肌(US)作为肌肉评估的一种替代方法受到了相当大的关注。然而,内部和内部的可靠性仍然存在争议。此外,对于使用US进行肌肉评估与肌肉质量或身体评估之间的关系,没有达成共识。我们的目的是验证肌肉测量使用US的有效性和可靠性及其与肌肉力量和身体评估的关系。方法:22例受试者均为健康男性。股四头肌厚度由三个不同的评分者进行测量。分类内相关系数(ICC)用于评估分类间和分类内的信度。四头肌的最大等速力量和握力分别作为下肢和上肢肌肉力量的测量。采用腿骨骼肌指数(SMI)评估腿部肌肉质量,通过身体阻抗分析和小腿围测量。结果:量表内信度良好,ICC(1,1)在0.957 ~ 0.993之间,ICC(1,3)在0.985 ~ 0.998之间。对于评估间信度,ICC(2,1)的值为0.904,ICC(2,3)的值为0.966,表明信度极好。腿部SMI与股四头肌厚度显著相关(r=0.36)。最大等速力量和握力与股四头肌厚度呈弱相关性,但有统计学意义(r=0.20, r=0.30)。股四头肌厚度与小腿围围之间的相关性无统计学意义。结论:应用US对健康人进行股四头肌肌肉评估是一种有效、可靠的技术。股四头肌厚度与上下肌力量和腿部SMI呈显著正相关。肌肉厚度评估可替代全身肌肉评估在临床设置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of Delayed Postoperative Rehabilitation on Patients with Valvular Heart Disease: A Retrospective Cohort Study. The Relationship between Physical Function and Quality of Life in Elderly People Requiring Long-term Care. Preoperative Posterior Pelvic Tilt Angle is Associated with Decreased Gait Speed and Hip Function in Older Patients with Hip Osteoarthritis. Refractory Severe Anti-SRP Myopathy that Improved with Long-term Rehabilitation Therapy: A Case Report. Therapeutic Intervention for Trunk Control Impairments in Central Nervous System Disorders: A Comprehensive Review of Methods and Efficacy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1