Challenging Issues in Diagnosis and Screening of BK Virus Nephropathy in Kidney Transplant Recipients, A Multicenter Experience in Iranian Population.

IF 0.7 4区 医学 Q4 UROLOGY & NEPHROLOGY Iranian journal of kidney diseases Pub Date : 2022-11-01 DOI:10.52547/ijkd.7143
Fatemeh Nili, Seyed Mohammadreza Khatami, Malihe Saberafsharian, Reza Shahsiah, Yadollah Shakiba, Golnar Seirafi, Yasaman Sadeghi, Maryam Miri, Reza Ataei, Maliheh Mohamadhoseini
{"title":"Challenging Issues in Diagnosis and Screening of BK Virus Nephropathy in Kidney Transplant Recipients, A Multicenter Experience in Iranian Population.","authors":"Fatemeh Nili, Seyed Mohammadreza Khatami, Malihe Saberafsharian, Reza Shahsiah, Yadollah Shakiba, Golnar Seirafi, Yasaman Sadeghi, Maryam Miri, Reza Ataei, Maliheh Mohamadhoseini","doi":"10.52547/ijkd.7143","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>BK virus nephropathy (BKVN) is an important complication of kidney transplantation and kidney biopsy remains the gold standard for its diagnosis. Urine/serum polymerase chain reaction (PCR) is a more sensitive diagnostic method, although it has some potential limitations.</p><p><strong>Methods: </strong>This study enrolled all kidney transplant recipients who underwent kidney transplant biopsy, collected from three medical centers. Urine and serum PCR results of the patients were also collected from the molecular laboratories. The cut-off value for positive viral DNA load in serum and urine were > 104 and > 107 copies/mL, respectively. Sensitivity, specifity, positive and negative predictive values (PPV, NPV) and cut off values for PCR results were compared with pathologic diagnosis among laboratories.</p><p><strong>Results: </strong>Among 369 biopsy samples, 33 (8.9%) had definite diagnosis of BKVN. PCR results were available for 138 cases. Three patients with definite BKVN had negative PCR results. In 22 patients, PCR was positive without evidence of BKVN. The overall sensitivity, specificity, PPV and NPV of PCR for detecting BKVN, based on a unique cut-off value, were 88, 81, 51, and 97%; respectively. The overall accuracy of PCR in all laboratories was high (82 to 86%), however significant inter-laboratory differences in sensitivity and specificity was found . A 2-log difference in threshold value for positive results was observed in one laboratory.</p><p><strong>Conclusion: </strong>PCR may show a significant variability between different laboratories. Interpretation of PCR results using a single cut-off value for all laboratories, may decrease the sensitivity for the diagnosis and screening of BKVN.</p>","PeriodicalId":14610,"journal":{"name":"Iranian journal of kidney diseases","volume":"16 6","pages":"368-373"},"PeriodicalIF":0.7000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian journal of kidney diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52547/ijkd.7143","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: BK virus nephropathy (BKVN) is an important complication of kidney transplantation and kidney biopsy remains the gold standard for its diagnosis. Urine/serum polymerase chain reaction (PCR) is a more sensitive diagnostic method, although it has some potential limitations.

Methods: This study enrolled all kidney transplant recipients who underwent kidney transplant biopsy, collected from three medical centers. Urine and serum PCR results of the patients were also collected from the molecular laboratories. The cut-off value for positive viral DNA load in serum and urine were > 104 and > 107 copies/mL, respectively. Sensitivity, specifity, positive and negative predictive values (PPV, NPV) and cut off values for PCR results were compared with pathologic diagnosis among laboratories.

Results: Among 369 biopsy samples, 33 (8.9%) had definite diagnosis of BKVN. PCR results were available for 138 cases. Three patients with definite BKVN had negative PCR results. In 22 patients, PCR was positive without evidence of BKVN. The overall sensitivity, specificity, PPV and NPV of PCR for detecting BKVN, based on a unique cut-off value, were 88, 81, 51, and 97%; respectively. The overall accuracy of PCR in all laboratories was high (82 to 86%), however significant inter-laboratory differences in sensitivity and specificity was found . A 2-log difference in threshold value for positive results was observed in one laboratory.

Conclusion: PCR may show a significant variability between different laboratories. Interpretation of PCR results using a single cut-off value for all laboratories, may decrease the sensitivity for the diagnosis and screening of BKVN.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
具有挑战性的问题
简介:BK病毒肾病
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian journal of kidney diseases
Iranian journal of kidney diseases UROLOGY & NEPHROLOGY-
CiteScore
2.50
自引率
0.00%
发文量
43
审稿时长
6-12 weeks
期刊介绍: The Iranian Journal of Kidney Diseases (IJKD), a peer-reviewed journal in English, is the official publication of the Iranian Society of Nephrology. The aim of the IJKD is the worldwide reflection of the knowledge produced by the scientists and clinicians in nephrology. Published quarterly, the IJKD provides a new platform for advancement of the field. The journal’s objective is to serve as a focal point for debates and exchange of knowledge and experience among researchers in a global context. Original papers, case reports, and invited reviews on all aspects of the kidney diseases, hypertension, dialysis, and transplantation will be covered by the IJKD. Research on the basic science, clinical practice, and socio-economics of renal health are all welcomed by the editors of the journal.
期刊最新文献
A Prediction Model of Early Diabetic Nephropathy Based on Conventional Ultrasound Parameters and Hematological Indices and Its Application. Association of Angiotensin Converting Enzyme Gene Deletion/Deletion Genotype with Risk of Autosomal Dominant Polycystic Kidney Disease: A Single-center Study from Iranian Azeri Turkish Population. Comparison of Serum Phosphate Levels in Critically Ill Patients with Acute Kidney Injury Undergoing Continuous Renal Replacement Therapy Using Different Dialysates. Spontaneous Tumor Lysis Syndrome as a Complication of Metastatic Breast Cancer: A Rare Case Report. The Diagnosis of Lupus Nephritis in A Patient with Autosomal Dominant Polycystic Kidney Disease: A Rare Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1