B. Yang, A. Lumpkin
{"title":"Simultaneous measurement of electron beam size and divergence with an undulator","authors":"B. Yang, A. Lumpkin","doi":"10.1109/PAC.1999.794406","DOIUrl":null,"url":null,"abstract":"We present the simultaneous measurement of beam divergence and source size based on the APS diagnostic undulator line. A 300-/spl mu/m-thick Si(400) crystal monochromator is used to measure the divergence with a resolution down to 3 /spl mu/rad (1 /spl mu/rad with the third harmonic). X-rays transmitted through the crystal are simultaneously used by a pinhole camera to measure the beam size, at a resolution of about 40 /spl mu/m. We demonstrate that this measurement of emittance is robust against fluctuations of lattice functions due to a partial cancellation of systematic errors present in each of the measurements.","PeriodicalId":20453,"journal":{"name":"Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1999.794406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

We present the simultaneous measurement of beam divergence and source size based on the APS diagnostic undulator line. A 300-/spl mu/m-thick Si(400) crystal monochromator is used to measure the divergence with a resolution down to 3 /spl mu/rad (1 /spl mu/rad with the third harmonic). X-rays transmitted through the crystal are simultaneously used by a pinhole camera to measure the beam size, at a resolution of about 40 /spl mu/m. We demonstrate that this measurement of emittance is robust against fluctuations of lattice functions due to a partial cancellation of systematic errors present in each of the measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用波动器同时测量电子束大小和散度
本文提出了基于APS诊断波动线的光束发散度和源尺寸的同时测量方法。使用300-/spl mu/m厚的Si(400)晶体单色仪测量散度,分辨率低至3 /spl mu/rad(三次谐波为1 /spl mu/rad)。通过晶体传输的x射线同时被针孔相机用来测量光束的大小,分辨率约为40 /spl mu/m。我们证明,由于每个测量中存在的系统误差部分抵消,这种发射度测量对晶格函数的波动具有鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characteristics of helium ion beams from multicusp source and study of beam transport Feedback systems for linear colliders Conceptual design of a vacuum system for a compact, high luminosity CESR upgrade Electro-optical detection of charged particle beams Pulsed neutron source using 100-MeV electron linac at Pohang Accelerator Laboratory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1