Novel Self-Expanding Interwoven Nitinol Stent for Treating Femoropopliteal Artery Disease: 12-Month Results of Single-Center First-in-Man Study.

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Endovascular Therapy Pub Date : 2024-10-01 Epub Date: 2023-03-16 DOI:10.1177/15266028231159243
Shuofei Yang, Qihong Ni, Weilun Wang, Jiaquan Chen, Xiangjiang Guo, Meng Ye, Lan Zhang, Guanhua Xue
{"title":"Novel Self-Expanding Interwoven Nitinol Stent for Treating Femoropopliteal Artery Disease: 12-Month Results of Single-Center First-in-Man Study.","authors":"Shuofei Yang, Qihong Ni, Weilun Wang, Jiaquan Chen, Xiangjiang Guo, Meng Ye, Lan Zhang, Guanhua Xue","doi":"10.1177/15266028231159243","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety and efficacy of Innospring<sup>®</sup> stent, a novel self-expanding interwoven nitinol stent, in treating femoropopliteal atherosclerotic lesions.</p><p><strong>Methods: </strong>A prospective, single-center, single-arm, first-in-human study enrolled 15 patients (mean age 73.1 years; 13 men) to evaluate the safety and efficacy of the Innospring<sup>®</sup> stent monitored by core laboratories. The inclusion criteria were claudication or ischemic rest pain, de novo lesions or nonstented restenosis, >70% stenosis, lesion length <20 cm, and a reference vessel diameter of 4-7 mm. The primary safety endpoint was 30-day major adverse events. The primary efficacy end point was stent patency at 12 months. Follow-up evaluations were conducted at 30 days, 6 months, and 12 months.</p><p><strong>Results: </strong>The lesion length was 6.1 ± 3.5 mm. Fourteen (93.3%) patients had lesions of the superficial femoral artery and 3 (20.0%) patients had lesions of the popliteal artery. Nine (60.0%) patients had moderate-to-severe calcified lesion. Technical and procedural success was 100%. No patients experienced major adverse events in the first 30 days. The Rutherford category showed significant and sustained improvement at 6 and 12 months. The 12-month follow-up radiographs obtained in 13 patients confirmed the absence of stent fractures in 100% of examinations. The cumulative primary stent patency rate at 6 and 12 months were 93.3% and 84.6%, respectively.</p><p><strong>Conclusion: </strong>Stenting of the superficial femoral and popliteal arteries using the Innospring<sup>®</sup> stent is safe and effective. This competing interwoven nitinol stent may provide superior stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.</p><p><strong>Clinical impact: </strong>Endovascular recanalization is a widely accepted and recommended treatment for symptomatic peripheral artery diseases. The Innospring® stent is a novel self-expanding interwoven stent containing eight nitinol wires with additional radial force, fracture-resistance, and visibility under fluoroscopy. This first-in-human study using the Innospring® stent in patients with femoropopliteal occlusive disease reported that stenting of the superficial femoral and popliteal arteries using the Innospring® stent is safe and effective. This competing interwoven nitinol stent may provide an impressive stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231159243","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the safety and efficacy of Innospring® stent, a novel self-expanding interwoven nitinol stent, in treating femoropopliteal atherosclerotic lesions.

Methods: A prospective, single-center, single-arm, first-in-human study enrolled 15 patients (mean age 73.1 years; 13 men) to evaluate the safety and efficacy of the Innospring® stent monitored by core laboratories. The inclusion criteria were claudication or ischemic rest pain, de novo lesions or nonstented restenosis, >70% stenosis, lesion length <20 cm, and a reference vessel diameter of 4-7 mm. The primary safety endpoint was 30-day major adverse events. The primary efficacy end point was stent patency at 12 months. Follow-up evaluations were conducted at 30 days, 6 months, and 12 months.

Results: The lesion length was 6.1 ± 3.5 mm. Fourteen (93.3%) patients had lesions of the superficial femoral artery and 3 (20.0%) patients had lesions of the popliteal artery. Nine (60.0%) patients had moderate-to-severe calcified lesion. Technical and procedural success was 100%. No patients experienced major adverse events in the first 30 days. The Rutherford category showed significant and sustained improvement at 6 and 12 months. The 12-month follow-up radiographs obtained in 13 patients confirmed the absence of stent fractures in 100% of examinations. The cumulative primary stent patency rate at 6 and 12 months were 93.3% and 84.6%, respectively.

Conclusion: Stenting of the superficial femoral and popliteal arteries using the Innospring® stent is safe and effective. This competing interwoven nitinol stent may provide superior stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.

Clinical impact: Endovascular recanalization is a widely accepted and recommended treatment for symptomatic peripheral artery diseases. The Innospring® stent is a novel self-expanding interwoven stent containing eight nitinol wires with additional radial force, fracture-resistance, and visibility under fluoroscopy. This first-in-human study using the Innospring® stent in patients with femoropopliteal occlusive disease reported that stenting of the superficial femoral and popliteal arteries using the Innospring® stent is safe and effective. This competing interwoven nitinol stent may provide an impressive stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型自膨胀交织镍钛诺支架用于治疗股骨干动脉疾病:12个月的单中心首例患者研究结果。
目的:评估新型自膨胀交织镍钛诺支架Innospring®治疗股动脉粥样硬化病变的安全性和有效性:这是一项前瞻性、单中心、单臂、首次纳入人体的研究,共招募了15名患者(平均年龄73.1岁;13名男性),评估由核心实验室监测的Innospring®支架的安全性和有效性。纳入标准为跛行或缺血性静息痛、新发病变或非支架再狭窄、狭窄程度大于70%、病变长度 结果:病变长度为6.1 cm,平均狭窄程度大于70%:病变长度为 6.1 ± 3.5 毫米。14例(93.3%)患者的病变位于股浅动脉,3例(20.0%)患者的病变位于腘动脉。9名患者(60.0%)有中度至重度钙化病变。技术和手术成功率为 100%。在最初的 30 天内,没有患者出现重大不良事件。6 个月和 12 个月后,卢瑟福分类显示病情得到了明显而持续的改善。对13名患者进行的12个月随访X光片检查证实,100%的患者没有支架断裂。6个月和12个月时的累积主要支架通畅率分别为93.3%和84.6%:结论:使用Innospring®支架对股浅动脉和腘动脉进行支架治疗是安全有效的。这种竞争性交织镍钛诺支架可提供卓越的支架完整性和抗断裂性,并可用于承受极端机械应力的区域:临床影响:血管内再通术是治疗无症状外周动脉疾病的公认和推荐疗法。Innospring®支架是一种新型自膨胀交织支架,包含八根镍钛诺丝,具有额外的径向力、抗断裂性和透视下可视性。这项首次在股骨腘动脉闭塞症患者中使用 Innospring® 支架进行的人体研究表明,使用 Innospring® 支架对股浅动脉和腘动脉进行支架治疗是安全有效的。这种竞争性交织镍钛诺支架可提供令人印象深刻的支架完整性和抗断裂性,并可用于承受极端机械应力的区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
期刊最新文献
Vascular Closure Devices For Axillary Artery Access: A Systematic Review and Meta-Analysis. A Statistical Shape Model of Infrarenal Aortic Necks in Patients With and Without Late Type Ia Endoleak After Endovascular Aneurysm Repair. Monocentric Evaluation of Physician-Modified Fenestrations or Parallel Endografts for Complex Aortic Diseases. Ethanol Embolization of Chest Wall Arteriovenous Malformations: Four-Year Findings. Deep Learning Prediction for Distal Aortic Remodeling After Thoracic Endovascular Aortic Repair in Stanford Type B Aortic Dissection.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1