A Simple Versatile Technique to Retrieve Polyaxial Tulip-head Spinal Pedicle Screws Following Failed Pedicle Screw Removal: A Technical Note With Analysis of Efficacy and Outcomes

IF 0.2 Q4 ORTHOPEDICS Techniques in Orthopaedics Pub Date : 2021-07-14 DOI:10.1097/BTO.0000000000000564
N. Uvaraj, Aju Bosco
{"title":"A Simple Versatile Technique to Retrieve Polyaxial Tulip-head Spinal Pedicle Screws Following Failed Pedicle Screw Removal: A Technical Note With Analysis of Efficacy and Outcomes","authors":"N. Uvaraj, Aju Bosco","doi":"10.1097/BTO.0000000000000564","DOIUrl":null,"url":null,"abstract":"Introduction: With increase in the number of thoracolumbar spine surgeries using pedicle screw instrumentation, there is a proportionate increase in the number of revision surgeries requiring implant removal. Lack of standardization in manufacturing spinal pedicle screws has led to diverse variations in their design and dimensions. Removal of polyaxial pedicle screws becomes extremely difficult when there is a mismatch between their tulip-head and the screwdriver. With the rapidly changing concepts and designs of spinal pedicle screws this problem may arise when the appropriate pedicle screw instrumentation is out of production. There may be a need for special instruments or an array of screwdrivers of various dimensions/designs to overcome this problem. We describe a simple yet versatile technique to remove polyaxial tulip-head pedicle screws using commonly available instruments in the spinal instrumentation set. Materials and Methods: Polyaxial screws were removed after converting them into monoblock screws using the appropriate set-screw screwdriver, a 25-mm long 5.5 mm rod, and a counter torque wrench. Results: Using this technique we have successfully removed 167 screws in 53 revision surgeries [instrumented fusions for lumbar degenerative diseases (n=21), thoracolumbar fractures (n=15), and scoliosis (n=17)]. No failed retrievals or complications like pedicle breach or neurological deficit were observed. Discussion: The described technique is simple to execute, effective, quick, and safe. It is versatile and can be used to remove polyaxial pedicle screws of any design in the thoracic and lumbar spine using the commonly available instruments in the routine spinal instrumentation set (appropriate set-screw screwdriver, a 25-mm long 5.5 mm rod, a counter torque wrench).","PeriodicalId":45336,"journal":{"name":"Techniques in Orthopaedics","volume":"3 1","pages":"171 - 174"},"PeriodicalIF":0.2000,"publicationDate":"2021-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTO.0000000000000564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: With increase in the number of thoracolumbar spine surgeries using pedicle screw instrumentation, there is a proportionate increase in the number of revision surgeries requiring implant removal. Lack of standardization in manufacturing spinal pedicle screws has led to diverse variations in their design and dimensions. Removal of polyaxial pedicle screws becomes extremely difficult when there is a mismatch between their tulip-head and the screwdriver. With the rapidly changing concepts and designs of spinal pedicle screws this problem may arise when the appropriate pedicle screw instrumentation is out of production. There may be a need for special instruments or an array of screwdrivers of various dimensions/designs to overcome this problem. We describe a simple yet versatile technique to remove polyaxial tulip-head pedicle screws using commonly available instruments in the spinal instrumentation set. Materials and Methods: Polyaxial screws were removed after converting them into monoblock screws using the appropriate set-screw screwdriver, a 25-mm long 5.5 mm rod, and a counter torque wrench. Results: Using this technique we have successfully removed 167 screws in 53 revision surgeries [instrumented fusions for lumbar degenerative diseases (n=21), thoracolumbar fractures (n=15), and scoliosis (n=17)]. No failed retrievals or complications like pedicle breach or neurological deficit were observed. Discussion: The described technique is simple to execute, effective, quick, and safe. It is versatile and can be used to remove polyaxial pedicle screws of any design in the thoracic and lumbar spine using the commonly available instruments in the routine spinal instrumentation set (appropriate set-screw screwdriver, a 25-mm long 5.5 mm rod, a counter torque wrench).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在椎弓根螺钉取出失败后恢复多轴郁金香头椎弓根螺钉的简单通用技术:技术笔记及疗效和结果分析
导言:随着胸腰椎椎弓根螺钉内固定手术数量的增加,需要取出植入物的翻修手术数量也相应增加。由于制造椎弓根螺钉缺乏标准化,导致其设计和尺寸存在多种差异。当多轴椎弓根螺钉的郁金香头和螺丝刀不匹配时,拆卸多轴椎弓根螺钉变得非常困难。随着椎弓根螺钉概念和设计的快速变化,当合适的椎弓根螺钉内固定停止生产时,可能会出现这个问题。可能需要特殊的仪器或各种尺寸/设计的一系列螺丝刀来克服这个问题。我们描述了一种简单而通用的技术,使用脊柱内固定装置中常用的器械去除多轴郁金香头椎弓根螺钉。材料和方法:使用合适的固定螺钉螺丝刀、长25mm的5.5 mm杆和反扭力扳手将多轴螺钉转换成单块螺钉,取出多轴螺钉。结果:使用该技术,我们在53例翻修手术中成功拆除了167颗螺钉[腰椎退行性疾病(21例)、胸腰椎骨折(15例)和脊柱侧凸(17例)的器械融合术]。无检索失败,无椎弓根断裂、神经功能缺损等并发症。讨论:所描述的技术执行简单、有效、快速和安全。它是多功能的,可以使用常规脊柱内固定装置中常用的器械(合适的固定螺钉螺丝刀,25毫米长5.5毫米杆,反扭力扳手)拆卸胸椎和腰椎的任何设计的多轴椎弓根螺钉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
31
期刊介绍: The purpose of Techniques in Orthopaedics is to provide information on the latest orthopaedic procedure as they are devised and used by top orthopaedic surgeons. The approach is technique-oriented, covering operations, manipulations, and instruments being developed and applied in such as arthroscopy, arthroplasty, and trauma. Each issue is guest-edited by an expert in the field and devoted to a single topic.
期刊最新文献
Perfect Circle Technique With C-arm Laser Augmentation Fixation of Distal Femur Fractures With the Use of Periarticular Tibial Locking Plates Single Incision Broström-Gould Surgery With Peroneal Debridement and Calcaneal Osteotomy Extensive Posteromedial Soft Tissue Release for Skeletally Mature Patients With Rigid Pes Cavus Deformity Kickstand Technique for Treatment of Valgus-Impacted Proximal Humerus Fractures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1