Holographic phase-retrieval method of near-field antenna pattern measurement for bolometer-array-equipped millimeter-wave telescopes

IF 1.7 3区 工程技术 Q2 ENGINEERING, AEROSPACE Journal of Astronomical Telescopes Instruments and Systems Pub Date : 2023-04-01 DOI:10.1117/1.JATIS.9.2.028003
R. Nakano, H. Takakura, Y. Sekimoto, J. Inatani, M. Sugimoto, S. Oguri, F. Matsuda
{"title":"Holographic phase-retrieval method of near-field antenna pattern measurement for bolometer-array-equipped millimeter-wave telescopes","authors":"R. Nakano, H. Takakura, Y. Sekimoto, J. Inatani, M. Sugimoto, S. Oguri, F. Matsuda","doi":"10.1117/1.JATIS.9.2.028003","DOIUrl":null,"url":null,"abstract":"Abstract. Wide field-of-view millimeter-wave telescopes with a bolometric detector array have been developed for cosmic microwave background radiation observations. For the purpose of laboratory verification of these telescopes, several studies have demonstrated near-field antenna measurements using a phase-sensitive detector that replaces a few representative pixels of the focal-plane detector array. We present a holographic phase-retrieval method that enables near-field measurements with the bolometric detector array as it is. We place a reference emitter at a fixed position and scan a signal emitter at the telescope aperture. These two emitters are phase-locked and generate interference patterns (holograms) on the focal plane, from which the amplitude and phase of the aperture field can be retrieved. We experimentally demonstrated this method with a crossed-Dragone telescope with a field-of-view that is 18  deg  ×   9  deg. In the demonstration, we placed a phase-sensitive detector at three detector positions on the focal plane. The antenna patterns calculated from the hologram, neglecting the directly measured phase information, were consistent with those calculated from both intensity and phase measurements at the −60-dB level at 180 GHz. Applying this method, the antenna patterns for all of the bolometric detectors on the focal plane can theoretically be measured simultaneously.","PeriodicalId":54342,"journal":{"name":"Journal of Astronomical Telescopes Instruments and Systems","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Astronomical Telescopes Instruments and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/1.JATIS.9.2.028003","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract. Wide field-of-view millimeter-wave telescopes with a bolometric detector array have been developed for cosmic microwave background radiation observations. For the purpose of laboratory verification of these telescopes, several studies have demonstrated near-field antenna measurements using a phase-sensitive detector that replaces a few representative pixels of the focal-plane detector array. We present a holographic phase-retrieval method that enables near-field measurements with the bolometric detector array as it is. We place a reference emitter at a fixed position and scan a signal emitter at the telescope aperture. These two emitters are phase-locked and generate interference patterns (holograms) on the focal plane, from which the amplitude and phase of the aperture field can be retrieved. We experimentally demonstrated this method with a crossed-Dragone telescope with a field-of-view that is 18  deg  ×   9  deg. In the demonstration, we placed a phase-sensitive detector at three detector positions on the focal plane. The antenna patterns calculated from the hologram, neglecting the directly measured phase information, were consistent with those calculated from both intensity and phase measurements at the −60-dB level at 180 GHz. Applying this method, the antenna patterns for all of the bolometric detectors on the focal plane can theoretically be measured simultaneously.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
辐射热计阵列毫米波望远镜近场天线方向图测量全息相位反演方法
摘要为观测宇宙微波背景辐射,研制了带辐射热计探测阵列的宽视场毫米波望远镜。为了对这些望远镜进行实验室验证,一些研究证明了使用相敏探测器代替焦平面探测器阵列的几个代表性像素的近场天线测量。我们提出了一种全息相位恢复方法,使近场测量与热测量探测器阵列一样。我们在固定位置放置一个参考发射极,在望远镜孔径处扫描一个信号发射极。这两个发射器是锁相的,在焦平面上产生干涉图样(全息图),从中可以提取孔径场的振幅和相位。我们用一架视场为18度× 9度的十字形龙式望远镜实验证明了这种方法。在演示中,我们在焦平面上的三个检测器位置放置了一个相敏检测器。忽略直接测量的相位信息,从全息图中计算出的天线方向图与180 GHz−60 db水平下的强度和相位测量结果一致。应用该方法,理论上可以同时测量焦平面上所有测热探测器的天线方向图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.40
自引率
13.00%
发文量
119
期刊介绍: The Journal of Astronomical Telescopes, Instruments, and Systems publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.
期刊最新文献
Design, implementation, and performance of the primary reflector for SALTUS Solar system science with the Single Aperture Large Telescope for Universe Studies space observatory Milky Way and nearby galaxy science with the SALTUS space observatory Adjustable X-ray optics: thin-film actuator measurement and figure correction performance FIREBall-2 UV balloon telescope in-flight calibration system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1