Carpal Tunnel Anthropometrics Using Acrylic Casts: A Cadaveric Study With Implications for Carpal Tunnel Release.

IF 1.8 Q2 ORTHOPEDICS HAND Pub Date : 2024-09-01 Epub Date: 2023-03-22 DOI:10.1177/15589447231160209
José D Carmo, Rui C Cardoso, Helder V Silva, Rui F Jesus
{"title":"Carpal Tunnel Anthropometrics Using Acrylic Casts: A Cadaveric Study With Implications for Carpal Tunnel Release.","authors":"José D Carmo, Rui C Cardoso, Helder V Silva, Rui F Jesus","doi":"10.1177/15589447231160209","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Abundant literature exists on the morphology of the carpal tunnel. Despite this, the shape of the carpal tunnel has been reported erratically, and most studies did not attempt to correlate findings with measurements taken from cadavers. The objective of this study was to perform a morphological analysis, determine the shape and mean dimensions of the carpal tunnel, determine the level of the narrowest area of the tunnel, and establish a set of values capable of serving as a reference for carpal tunnel release.</p><p><strong>Methods: </strong>The carpal tunnels of 20 fresh cadaveric hands were dissected, and acrylic casts were created and measured using industrial computed tomography.</p><p><strong>Results: </strong>Of the 20 casts, 19 were shaped like elliptic cylinders, with little variation in their measurements along the length. The location of the narrowest section of the carpal tunnel is very different among casts, and the length of the roof of the carpal tunnel ranged from 21.26 to 29.86 mm.</p><p><strong>Conclusions: </strong>The most common shape of the carpal tunnel is an elliptic cylinder. Because of the unpredictability of the location of the narrowest area of the carpal tunnel, carpal tunnel release must continue through all extension of its roof. We advise that the release should rarely be extended distally more than 30 mm from the distal palmar wrist crease, which corresponds, in most cases, to the middle of the pisiform.</p>","PeriodicalId":12902,"journal":{"name":"HAND","volume":" ","pages":"924-930"},"PeriodicalIF":1.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11342692/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HAND","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15589447231160209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Abundant literature exists on the morphology of the carpal tunnel. Despite this, the shape of the carpal tunnel has been reported erratically, and most studies did not attempt to correlate findings with measurements taken from cadavers. The objective of this study was to perform a morphological analysis, determine the shape and mean dimensions of the carpal tunnel, determine the level of the narrowest area of the tunnel, and establish a set of values capable of serving as a reference for carpal tunnel release.

Methods: The carpal tunnels of 20 fresh cadaveric hands were dissected, and acrylic casts were created and measured using industrial computed tomography.

Results: Of the 20 casts, 19 were shaped like elliptic cylinders, with little variation in their measurements along the length. The location of the narrowest section of the carpal tunnel is very different among casts, and the length of the roof of the carpal tunnel ranged from 21.26 to 29.86 mm.

Conclusions: The most common shape of the carpal tunnel is an elliptic cylinder. Because of the unpredictability of the location of the narrowest area of the carpal tunnel, carpal tunnel release must continue through all extension of its roof. We advise that the release should rarely be extended distally more than 30 mm from the distal palmar wrist crease, which corresponds, in most cases, to the middle of the pisiform.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用丙烯酸铸模的腕管人体测量学:尸体研究对腕管松解术的启示
背景:关于腕管形态的文献很多。尽管如此,有关腕管形态的报道并不稳定,而且大多数研究并未尝试将研究结果与尸体测量结果进行关联。本研究的目的是进行形态分析,确定腕管的形状和平均尺寸,确定腕管最窄区域的水平,并建立一套可作为腕管松解参考的数值:方法:解剖 20 只新鲜尸体手的腕管,制作丙烯酸模型,并使用工业计算机断层扫描进行测量:结果:在 20 个模型中,19 个的形状像椭圆形圆柱体,沿长度方向的测量值变化不大。不同模型腕管最窄部分的位置差异很大,腕管顶端的长度从 21.26 毫米到 29.86 毫米不等:结论:腕管最常见的形状是椭圆形圆柱体。结论:腕管最常见的形状是椭圆形圆柱体。由于腕管最窄区域的位置难以预测,因此腕管松解必须持续到腕管顶端的所有延伸部分。我们建议,腕管松解的远端距离腕掌远端皱襞应很少超过 30 毫米,在大多数情况下,这相当于腕桡骨的中部。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
HAND
HAND Medicine-Surgery
CiteScore
3.30
自引率
0.00%
发文量
209
期刊介绍: HAND is the official journal of the American Association for Hand Surgery and is a peer-reviewed journal featuring articles written by clinicians worldwide presenting current research and clinical work in the field of hand surgery. It features articles related to all aspects of hand and upper extremity surgery and the post operative care and rehabilitation of the hand.
期刊最新文献
Comparison of 2 Types of Local Anesthetic Techniques in the Reduction of Distal Radius Fracture: A Prospective Cohort Study. Ischemia Time in Extremity Allotransplantation: A Comprehensive Review. The Super-Turbocharged End-to-Side Abductor Digiti Minimi and Anterior Interosseous Double Nerve Transfer Is Associated With Improved Ulnar Intrinsic Function. Chatbot Demonstrates Moderate Interrater Reliability in Billing for Hand Surgery Clinic Encounters. Financial Toxicity Among Patients With Traumatic Finger Amputation: A Retrospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1