D. Candal, M. Bulterys, E. Abrams, R. Steketee, B. Parekh
{"title":"Efficacy of a Less-Sensitive Enzyme Immunoassay (3A11-LS) for Early Diagnosis of Human Immunodeficiency Virus Type 1 Infection in Infants","authors":"D. Candal, M. Bulterys, E. Abrams, R. Steketee, B. Parekh","doi":"10.1128/CDLI.8.6.1282-1285.2001","DOIUrl":null,"url":null,"abstract":"ABSTRACT We evaluated a less-sensitive enzyme immunoassay (3A11-LS) for its possible use for early diagnosis of human immunodeficiency virus type 1 (HIV-1) infection in infants. The results were compared with those from the immunoglobulin G-capture enzyme immunoassay. A total of 239 sera from 77 infants were tested. All 25 sera from the 10 infants born to seronegative mothers were found to be negative by both assays. Forty-one seroreverting infants showed a complete decay of maternal antibodies by 4 months by the 3A11-LS assay. However, the assay detected HIV antibodies in only 9 (36%) of 25 sera collected from infected infants between 4 and 6 months and in 27 (63%) of 43 sera collected after 6 months of age. Further analysis with alternative cutoff values indicated that the 3A11-LS had a sensitivity of 12 to 44% and a specificity of 90 to 100% for infants between 4–6 months of age. This data suggest that a diagnosis of HIV infection in some of the infants could be made after 4 months of age by the 3A11-LS assay, although a negative 3A11-LS test result may not rule out infection and may require a further followup.","PeriodicalId":10395,"journal":{"name":"Clinical Diagnostic Laboratory Immunology","volume":"16 1","pages":"1282 - 1285"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Diagnostic Laboratory Immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1128/CDLI.8.6.1282-1285.2001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
ABSTRACT We evaluated a less-sensitive enzyme immunoassay (3A11-LS) for its possible use for early diagnosis of human immunodeficiency virus type 1 (HIV-1) infection in infants. The results were compared with those from the immunoglobulin G-capture enzyme immunoassay. A total of 239 sera from 77 infants were tested. All 25 sera from the 10 infants born to seronegative mothers were found to be negative by both assays. Forty-one seroreverting infants showed a complete decay of maternal antibodies by 4 months by the 3A11-LS assay. However, the assay detected HIV antibodies in only 9 (36%) of 25 sera collected from infected infants between 4 and 6 months and in 27 (63%) of 43 sera collected after 6 months of age. Further analysis with alternative cutoff values indicated that the 3A11-LS had a sensitivity of 12 to 44% and a specificity of 90 to 100% for infants between 4–6 months of age. This data suggest that a diagnosis of HIV infection in some of the infants could be made after 4 months of age by the 3A11-LS assay, although a negative 3A11-LS test result may not rule out infection and may require a further followup.