{"title":"The effect of intermittent heating on surface temperatures in rooms","authors":"D.P. Bloomfield","doi":"10.1016/0007-3628(75)90027-4","DOIUrl":null,"url":null,"abstract":"<div><p>This paper presents a simple approximate method of calculating surface temperatures resulting from a repeated square wave heat input to a room. The calculated values are shown to give reasonable agreement with results obtained on an electrical analogue. Values of thermal impedance for single and multi-layer walls are tabulated.</p></div>","PeriodicalId":9442,"journal":{"name":"Building Science","volume":"10 2","pages":"Pages 111-125"},"PeriodicalIF":0.0000,"publicationDate":"1975-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0007-3628(75)90027-4","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Science","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0007362875900274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
This paper presents a simple approximate method of calculating surface temperatures resulting from a repeated square wave heat input to a room. The calculated values are shown to give reasonable agreement with results obtained on an electrical analogue. Values of thermal impedance for single and multi-layer walls are tabulated.