High-sensitivity method for the determination of LSD and 2-oxo-3-hydroxy-LSD in oral fluid by liquid chromatography‒tandem mass spectrometry.

IF 2.8 4区 医学 Q2 TOXICOLOGY Forensic Toxicology Pub Date : 2022-07-01 DOI:10.1007/s11419-022-00622-0
Kelly Francisco da Cunha, Julia Martinelli Magalhães Kahl, Taís Regina Fiorentin, Karina Diniz Oliveira, Jose Luiz Costa
{"title":"High-sensitivity method for the determination of LSD and 2-oxo-3-hydroxy-LSD in oral fluid by liquid chromatography‒tandem mass spectrometry.","authors":"Kelly Francisco da Cunha,&nbsp;Julia Martinelli Magalhães Kahl,&nbsp;Taís Regina Fiorentin,&nbsp;Karina Diniz Oliveira,&nbsp;Jose Luiz Costa","doi":"10.1007/s11419-022-00622-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We have developed and validated a high-sensitivity method to quantify lysergic acid diethylamide (LSD) and 2-oxo-3-hydroxy-LSD (OH-LSD) in oral fluid samples using liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC‒MS/MS). The method was applied to the quantification of both substances in 42 authentic oral fluid samples.</p><p><strong>Methods: </strong>A liquid-liquid extraction was performed using 500 µL each of samples (oral fluid samples collected using Quantisal™ device) and dichloromethane/isopropanol mixture (1:1, v/v). Enzymatic hydrolysis was evaluated to cleave glucuronide metabolites.</p><p><strong>Results: </strong>The limit of quantification was 0.01 ng/mL for both LSD and OH-LSD. The linearity was assessed between 0.01 and 5 ng/mL. Imprecision and bias were not higher than 10.2% for both analytes. Extraction recovery was higher than 69%. The analytes were stable in the autosampler at 10 °C for 24 h, and up to 30 days at 4 and -20 °C. The method was applied to the analysis of 42 oral fluid samples. LSD was detected in all samples (concentrations between 0.02 and 175 ng/mL), and OH-LSD was detected in 20 samples (concentrations between 0.01 and 1.53 ng/mL).</p><p><strong>Conclusions: </strong>A high-sensitive method was fully validated and applied to authentic samples. To our knowledge, this is the first work to report concentrations of LSD and OH-LSD in authentic oral fluid samples.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-022-00622-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: We have developed and validated a high-sensitivity method to quantify lysergic acid diethylamide (LSD) and 2-oxo-3-hydroxy-LSD (OH-LSD) in oral fluid samples using liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC‒MS/MS). The method was applied to the quantification of both substances in 42 authentic oral fluid samples.

Methods: A liquid-liquid extraction was performed using 500 µL each of samples (oral fluid samples collected using Quantisal™ device) and dichloromethane/isopropanol mixture (1:1, v/v). Enzymatic hydrolysis was evaluated to cleave glucuronide metabolites.

Results: The limit of quantification was 0.01 ng/mL for both LSD and OH-LSD. The linearity was assessed between 0.01 and 5 ng/mL. Imprecision and bias were not higher than 10.2% for both analytes. Extraction recovery was higher than 69%. The analytes were stable in the autosampler at 10 °C for 24 h, and up to 30 days at 4 and -20 °C. The method was applied to the analysis of 42 oral fluid samples. LSD was detected in all samples (concentrations between 0.02 and 175 ng/mL), and OH-LSD was detected in 20 samples (concentrations between 0.01 and 1.53 ng/mL).

Conclusions: A high-sensitive method was fully validated and applied to authentic samples. To our knowledge, this is the first work to report concentrations of LSD and OH-LSD in authentic oral fluid samples.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
液相色谱-串联质谱法测定口服液中LSD和2-氧-3-羟基LSD的高灵敏度。
目的:建立并验证了液-液萃取-液相色谱-串联质谱(LC-MS /MS)定量口服液样品中麦角酸二乙胺(LSD)和2-氧-3-羟基LSD (OH-LSD)的高灵敏度方法。将该方法应用于42份正宗口服液样品中这两种物质的定量分析。方法:各样品(口服液样品采用Quantisal™装置采集)500µL,二氯甲烷/异丙醇混合物(1:1,v/v)进行液-液萃取。评价酶解对葡萄糖醛酸代谢产物的裂解作用。结果:LSD和OH-LSD的定量限均为0.01 ng/mL。在0.01 ~ 5 ng/mL之间进行线性评价。两种分析物的不精密度和偏差均不高于10.2%。提取回收率大于69%。分析物在10°C自动进样器中稳定24小时,在4°C和-20°C下可达30天。将该方法应用于42份口腔液体样本的分析。所有样品中均检测到LSD(浓度在0.02 ~ 175 ng/mL之间),20个样品中检测到OH-LSD(浓度在0.01 ~ 1.53 ng/mL之间)。结论:该方法灵敏度高,可用于真实样品。据我们所知,这是第一次报道在真实口服液样本中LSD和OH-LSD浓度的工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Forensic Toxicology
Forensic Toxicology TOXICOLOGY-
CiteScore
5.80
自引率
9.10%
发文量
40
审稿时长
3 months
期刊介绍: The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published. Forensic Toxicology is the official publication of the Japanese Association of Forensic Toxicology (JAFT) and is the continuation of the Japanese Journal of Forensic Toxicology (ISSN 0915-9606).
期刊最新文献
Elucidation of toxic effects of 1,2-diacetylbenzene: an in silico study Bioinformatics-driven untargeted metabolomic profiling for clinical screening of methamphetamine abuse Postmortem distribution of ropivacaine and its metabolite in human body fluids and solid tissues by GC–MS/MS using standard addition method Development of a simple estimation method of serum caffeine concentration using a point-of-care test kit for urinary caffeine. In vivo assessment of the nephrotoxic effects of the synthetic cannabinoid AB-FUBINACA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1