{"title":"Primary placement of low-profile or 'button' versus traditional balloon-retention radiologically inserted gastrostomy catheters in adults: a retrospective review.","authors":"Hassan Al-Balas, Zeyad Metwalli, Iftikhar Burney, David Sada","doi":"10.1136/bmjgast-2023-001118","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>De novo percutaneous placement of radiologically inserted low-profile or 'button-type' gastrostomy catheters (LPG) is infrequently reported in adults. This study compares the safety and clinical outcomes of primary percutaneous placement of LPG catheters and traditional balloon-retention gastrostomy catheters (TG) using image guidance at a single institution.</p><p><strong>Design: </strong>This was a retrospective, single-institution review comparing initial LPG and TG radiologically inserted catheter placements in a 36-month time period. The age, gender, indication, catheter type and method of anaesthesia of 139 consecutive initial gastrostomy placement procedures were recorded. Total catheter days without intervention, major and minor complications, reasons for reintervention, and procedure fluoroscopy times were compared.</p><p><strong>Results: </strong>During the 36-month study period, 61 LPG and 78 TG catheters were placed. Mean total catheter days prior to intervention was 137 days in the LPG group and 128 days in the TG group (p=0.70). Minor complications including cellulitis, pericatheter leakage and early catheter occlusion occurred in 4.9% (3/61) in the LPG group and 9% (7/78) in the TG group (p=0.5). Major complications including early catheter dislodgement and bleeding requiring transfusion (in one patient) occurred in 4.9% (3/61) in the LPG group and 7.7% (6/78) in the TG group (p=0.4). Procedure fluoroscopy time was lower in the LPG group (2.56 min) compared with the TG group (4.21 min) (p<0.005).</p><p><strong>Conclusion: </strong>Primary placement of low-profile or 'button-type' gastrostomy catheters is technically feasible with a low complication rate similar to that of traditional radiologically inserted gastrostomy catheters.</p>","PeriodicalId":9235,"journal":{"name":"BMJ Open Gastroenterology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/dd/73/bmjgast-2023-001118.PMC10030477.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Gastroenterology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjgast-2023-001118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: De novo percutaneous placement of radiologically inserted low-profile or 'button-type' gastrostomy catheters (LPG) is infrequently reported in adults. This study compares the safety and clinical outcomes of primary percutaneous placement of LPG catheters and traditional balloon-retention gastrostomy catheters (TG) using image guidance at a single institution.
Design: This was a retrospective, single-institution review comparing initial LPG and TG radiologically inserted catheter placements in a 36-month time period. The age, gender, indication, catheter type and method of anaesthesia of 139 consecutive initial gastrostomy placement procedures were recorded. Total catheter days without intervention, major and minor complications, reasons for reintervention, and procedure fluoroscopy times were compared.
Results: During the 36-month study period, 61 LPG and 78 TG catheters were placed. Mean total catheter days prior to intervention was 137 days in the LPG group and 128 days in the TG group (p=0.70). Minor complications including cellulitis, pericatheter leakage and early catheter occlusion occurred in 4.9% (3/61) in the LPG group and 9% (7/78) in the TG group (p=0.5). Major complications including early catheter dislodgement and bleeding requiring transfusion (in one patient) occurred in 4.9% (3/61) in the LPG group and 7.7% (6/78) in the TG group (p=0.4). Procedure fluoroscopy time was lower in the LPG group (2.56 min) compared with the TG group (4.21 min) (p<0.005).
Conclusion: Primary placement of low-profile or 'button-type' gastrostomy catheters is technically feasible with a low complication rate similar to that of traditional radiologically inserted gastrostomy catheters.
期刊介绍:
BMJ Open Gastroenterology is an online-only, peer-reviewed, open access gastroenterology journal, dedicated to publishing high-quality medical research from all disciplines and therapeutic areas of gastroenterology. It is the open access companion journal of Gut and is co-owned by the British Society of Gastroenterology. The journal publishes all research study types, from study protocols to phase I trials to meta-analyses, including small or specialist studies. Publishing procedures are built around continuous publication, publishing research online as soon as the article is ready.