A.F. Romano-Munive , C. Moctezuma-Velázquez , J. Sauma-Rodríguez , P. Ramos-Martínez , A. Torre-Delgadillo
{"title":"CD138 immunohistochemistry identifies more plasma cells compared with hematoxylin and eosin staining in autoimmune hepatitis. An observational study","authors":"A.F. Romano-Munive , C. Moctezuma-Velázquez , J. Sauma-Rodríguez , P. Ramos-Martínez , A. Torre-Delgadillo","doi":"10.1016/j.rgmxen.2022.08.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Autoimmune hepatitis (AIH) is associated with periportal infiltration by plasma cells. Plasma cell detection is routinely performed through hematoxylin and eosin (H&E) staining. The present study aimed to assess the utility of CD138, an immunohistochemical plasma cell marker, in the evaluation of AIH.</p></div><div><h3>Materials and methods</h3><p>A retrospective study was conducted, in which cases consistent with AIH, within the time frame of 2001 and 2011, were collected. Routine H&E-stained sections were used for evaluation. CD138 immunohistochemistry (IHC) was performed to detect plasma cells.</p></div><div><h3>Results</h3><p>Sixty biopsies were included. In the H&E group, the median and interquartile range (IQR) was 6 (4-9) plasma cells/high power field (HPF) and was 10 (IQR 6-20) plasma cells/HPF in the CD138 group (p < 0.001). There was a significant correlation between the number of plasma cells determined by H&E and CD138 (p = 0.31, p = 0.01). No significant correlation was found between the number of plasma cells determined by CD138 and IgG level (p = 0.21, p = 0.09) or stage of fibrosis (p = 0.12, p = 0.35), or between IgG level and stage of fibrosis (p = 0.17, p = 0.17). No significant correlation was found between the treatment response and the number of plasma cells determined by H&E (p = 0.11, p = 0.38), CD138 (p = 0.07, p = 0.55), or stage of fibrosis (p = 0.16, p = 0.20). CD138 expression was different between the treatment response groups (p = 0.04).</p></div><div><h3>Conclusion</h3><p>CD138 increased the detection of plasma cells in liver biopsies of patients with AIH, when compared with routine H&E staining. However, there was no correlation between the number of plasma cells determined by CD138 and serum IgG levels, stage of fibrosis, or response to treatment.</p></div>","PeriodicalId":74705,"journal":{"name":"Revista de gastroenterologia de Mexico (English)","volume":"89 1","pages":"Pages 52-56"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2255534X23000270/pdfft?md5=148927a77132514dce6a9aad4fe4a080&pid=1-s2.0-S2255534X23000270-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de gastroenterologia de Mexico (English)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2255534X23000270","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Autoimmune hepatitis (AIH) is associated with periportal infiltration by plasma cells. Plasma cell detection is routinely performed through hematoxylin and eosin (H&E) staining. The present study aimed to assess the utility of CD138, an immunohistochemical plasma cell marker, in the evaluation of AIH.
Materials and methods
A retrospective study was conducted, in which cases consistent with AIH, within the time frame of 2001 and 2011, were collected. Routine H&E-stained sections were used for evaluation. CD138 immunohistochemistry (IHC) was performed to detect plasma cells.
Results
Sixty biopsies were included. In the H&E group, the median and interquartile range (IQR) was 6 (4-9) plasma cells/high power field (HPF) and was 10 (IQR 6-20) plasma cells/HPF in the CD138 group (p < 0.001). There was a significant correlation between the number of plasma cells determined by H&E and CD138 (p = 0.31, p = 0.01). No significant correlation was found between the number of plasma cells determined by CD138 and IgG level (p = 0.21, p = 0.09) or stage of fibrosis (p = 0.12, p = 0.35), or between IgG level and stage of fibrosis (p = 0.17, p = 0.17). No significant correlation was found between the treatment response and the number of plasma cells determined by H&E (p = 0.11, p = 0.38), CD138 (p = 0.07, p = 0.55), or stage of fibrosis (p = 0.16, p = 0.20). CD138 expression was different between the treatment response groups (p = 0.04).
Conclusion
CD138 increased the detection of plasma cells in liver biopsies of patients with AIH, when compared with routine H&E staining. However, there was no correlation between the number of plasma cells determined by CD138 and serum IgG levels, stage of fibrosis, or response to treatment.