Xi Wang, Le Yang, Yeling Zhu, Weicai Wang, Chen Zhou, Yang Cao, Baicheng Bao, Jiazhi Li
{"title":"Total mesialization of the mandibular dentition using a mini-implant-supported device : A finite element analysis.","authors":"Xi Wang, Le Yang, Yeling Zhu, Weicai Wang, Chen Zhou, Yang Cao, Baicheng Bao, Jiazhi Li","doi":"10.1007/s00056-023-00502-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Total mandibular arch mesialization using mini-implants is challenging due to anatomic limitations. The aim of this study was to introduce a mini-implant-supported device for total mesialization of the mandibular dentition and to analyze the biomechanical properties of the device.</p><p><strong>Methods: </strong>Finite element models were constructed to explore the effect of friction and force direction on the force transmission efficiency of the device. In addition, the three-dimensional displacement of each tooth was evaluated with two force application points (2 or 8 mm hooks) under three force conditions (symmetric: 150 g of force on both sides, or asymmetric: 100 and 200 g of force on each side).</p><p><strong>Results: </strong>The force transmission efficiency was 66.7% under a friction coefficient of 0.15 and parallel pushing and pulling forces. The force transmission efficiency was 65.90 and 66.63% when the pushing force was 15° away from the pulling force on the sagittal and horizontal planes, respectively. The mandibular dentition moved mesially with a greater tendency for incisor labial crown tipping, mesial molar rotation and buccal second molar crown tipping when using the 8 mm hook compared to that when using the 2 mm hook. Rigid archwires resulted in more consistent tooth mesialization than stainless steel archwires. Asymmetric forces resulted in asymmetric dental arch mesialization.</p><p><strong>Conclusion: </strong>The forces transmitted by the presented mini-implant-supported device varied depending on the friction level and force direction. The device should be able to achieve symmetric or asymmetric total mesialization of the mandibular dentition.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-023-00502-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Total mandibular arch mesialization using mini-implants is challenging due to anatomic limitations. The aim of this study was to introduce a mini-implant-supported device for total mesialization of the mandibular dentition and to analyze the biomechanical properties of the device.
Methods: Finite element models were constructed to explore the effect of friction and force direction on the force transmission efficiency of the device. In addition, the three-dimensional displacement of each tooth was evaluated with two force application points (2 or 8 mm hooks) under three force conditions (symmetric: 150 g of force on both sides, or asymmetric: 100 and 200 g of force on each side).
Results: The force transmission efficiency was 66.7% under a friction coefficient of 0.15 and parallel pushing and pulling forces. The force transmission efficiency was 65.90 and 66.63% when the pushing force was 15° away from the pulling force on the sagittal and horizontal planes, respectively. The mandibular dentition moved mesially with a greater tendency for incisor labial crown tipping, mesial molar rotation and buccal second molar crown tipping when using the 8 mm hook compared to that when using the 2 mm hook. Rigid archwires resulted in more consistent tooth mesialization than stainless steel archwires. Asymmetric forces resulted in asymmetric dental arch mesialization.
Conclusion: The forces transmitted by the presented mini-implant-supported device varied depending on the friction level and force direction. The device should be able to achieve symmetric or asymmetric total mesialization of the mandibular dentition.
期刊介绍:
The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.