Michał J Stasiowski, Anna Duława, Seweryn Król, Radosław Marciniak, Wojciech Kaspera, Ewa Niewiadomska, Lech Krawczyk, Piotr Ładziński, Beniamin O Grabarek, Przemysław Jałowiecki
{"title":"Polyspikes and Rhythmic Polyspikes During Volatile Induction of General Anesthesia With Sevoflurane Result in Bispectral Index Variations.","authors":"Michał J Stasiowski, Anna Duława, Seweryn Król, Radosław Marciniak, Wojciech Kaspera, Ewa Niewiadomska, Lech Krawczyk, Piotr Ładziński, Beniamin O Grabarek, Przemysław Jałowiecki","doi":"10.1177/1550059420974571","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Although electroencephalography (EEG)-based indices may show artifactual values, raw EEG signal is seldom used to monitor the depth of volatile induction of general anesthesia (VIGA). The current analysis aimed to identify whether bispectral index (BIS) variations reliably reflect the actual depth of general anesthesia during presence of different types of epileptiform patterns (EPs) in EEGs during induction of general anesthesia.</p><p><strong>Methods: </strong>Sixty patients receiving either VIGA with sevoflurane using increasing concentrations (group VIMA) or vital capacity (group VCRII) technique or intravenous single dose of propofol (group PROP) were included. Monitoring included facial electromyography (fEMG), fraction of inspired sevoflurane (FiAA), fraction of expired sevoflurane (FeAA), minimal alveolar concentration (MAC) of sevoflurane, BIS, standard EEG, and hemodynamic parameters.</p><p><strong>Results: </strong>In the PROP group no EPs were observed. During different stages of VIGA with sevoflurane in the VIMA and VCRII groups, presence of polyspikes and rhythmic polyspikes in patients' EEGs resulted in artifactual BIS values indicating a false awareness/wakefulness from anesthesia, despite no concomitant change of FiAA, FeAA, and MAC of sevoflurane. Periodic epileptiform discharges did not result in aberrant BIS values.</p><p><strong>Conclusion: </strong>Our results suggest that raw EEG correlate it with values of BIS, FiAA, FeAA, and MAC of sevoflurane during VIGA. It seems that because artifactual BIS values indicating false awareness/wakefulness as a result of presence of polyspikes and rhythmic polyspikes in patients' EEGs may be misleading to an anesthesiologist, leading to unintentional administration of toxic concentration of sevoflurane in ventilation gas.</p>","PeriodicalId":10682,"journal":{"name":"Clinical EEG and Neuroscience","volume":"54 3","pages":"289-304"},"PeriodicalIF":1.6000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1550059420974571","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical EEG and Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/1550059420974571","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 6
Abstract
Background: Although electroencephalography (EEG)-based indices may show artifactual values, raw EEG signal is seldom used to monitor the depth of volatile induction of general anesthesia (VIGA). The current analysis aimed to identify whether bispectral index (BIS) variations reliably reflect the actual depth of general anesthesia during presence of different types of epileptiform patterns (EPs) in EEGs during induction of general anesthesia.
Methods: Sixty patients receiving either VIGA with sevoflurane using increasing concentrations (group VIMA) or vital capacity (group VCRII) technique or intravenous single dose of propofol (group PROP) were included. Monitoring included facial electromyography (fEMG), fraction of inspired sevoflurane (FiAA), fraction of expired sevoflurane (FeAA), minimal alveolar concentration (MAC) of sevoflurane, BIS, standard EEG, and hemodynamic parameters.
Results: In the PROP group no EPs were observed. During different stages of VIGA with sevoflurane in the VIMA and VCRII groups, presence of polyspikes and rhythmic polyspikes in patients' EEGs resulted in artifactual BIS values indicating a false awareness/wakefulness from anesthesia, despite no concomitant change of FiAA, FeAA, and MAC of sevoflurane. Periodic epileptiform discharges did not result in aberrant BIS values.
Conclusion: Our results suggest that raw EEG correlate it with values of BIS, FiAA, FeAA, and MAC of sevoflurane during VIGA. It seems that because artifactual BIS values indicating false awareness/wakefulness as a result of presence of polyspikes and rhythmic polyspikes in patients' EEGs may be misleading to an anesthesiologist, leading to unintentional administration of toxic concentration of sevoflurane in ventilation gas.
期刊介绍:
Clinical EEG and Neuroscience conveys clinically relevant research and development in electroencephalography and neuroscience. Original articles on any aspect of clinical neurophysiology or related work in allied fields are invited for publication.