{"title":"High-power laser lithotripsy - do we treat or harm? Histological evaluation of temperature effects in an in vivo study with thulium fiber laser.","authors":"Angelis Peteinaris, Arman Tsaturyan, Vasiliki Bravou, Vasileios Tatanis, Gabriel Faria-Costa, Konstantinos Pagonis, Solon Faitatziadis, Athanasios Vagionis, Evangelos Liatsikos, Panagiotis Kallidonis","doi":"10.5173/ceju.2023.24","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this study was to evaluate the possible histopathological alterations that occur in the kidneys due to a continuous temperature increase above 43°C for one hour of lithotripsy using a newly introduced thulium fiber laser (TFL).</p><p><strong>Material and methods: </strong>Two female pigs were used. After the insertion of a 9.5/11.5 ureteral access sheath, flexible ureteroscopy and laser lithotripsy for one hour were conducted. A TFL laser with a 200-μm fiber was used. The power setting used was 8 W (0.5 J × 16 Hz). A K-type thermocouple was inserted and fixed in the upper calyx of the right porcine kidney to record the temperature in the pelvicalyceal system during the laser activation. Second-look flexible nephroscopy followed by nephrectomy and pathohistological evaluation of the operated kidney was performed one week after the procedure in the first pig and 2 weeks after the surgery in the second pig.</p><p><strong>Results: </strong>Flexible nephroscopy did not reveal significant differences between the 2 porcine kidneys. Nevertheless, the histopathological report demonstrated severe alterations in the kidney of the first pig. Mild changes were reported in the kidney of the second pig. A significant improvement in inflammation and haemorrhagic lesions was demonstrated when comparing the 2 kidneys.</p><p><strong>Conclusions: </strong>The difference demonstrated between the 2 kidneys based on the histopathological report shows that the healing process is capable of improving severe to mild alterations within a one-week time frame. Two weeks after the surgery, only minor changes were observed, suggesting that even temperature increases above the threshold can be tolerated regarding renal damage.</p>","PeriodicalId":9744,"journal":{"name":"Central European Journal of Urology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/7b/0e/CEJU-76-24.PMC10091897.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Central European Journal of Urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5173/ceju.2023.24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: The aim of this study was to evaluate the possible histopathological alterations that occur in the kidneys due to a continuous temperature increase above 43°C for one hour of lithotripsy using a newly introduced thulium fiber laser (TFL).
Material and methods: Two female pigs were used. After the insertion of a 9.5/11.5 ureteral access sheath, flexible ureteroscopy and laser lithotripsy for one hour were conducted. A TFL laser with a 200-μm fiber was used. The power setting used was 8 W (0.5 J × 16 Hz). A K-type thermocouple was inserted and fixed in the upper calyx of the right porcine kidney to record the temperature in the pelvicalyceal system during the laser activation. Second-look flexible nephroscopy followed by nephrectomy and pathohistological evaluation of the operated kidney was performed one week after the procedure in the first pig and 2 weeks after the surgery in the second pig.
Results: Flexible nephroscopy did not reveal significant differences between the 2 porcine kidneys. Nevertheless, the histopathological report demonstrated severe alterations in the kidney of the first pig. Mild changes were reported in the kidney of the second pig. A significant improvement in inflammation and haemorrhagic lesions was demonstrated when comparing the 2 kidneys.
Conclusions: The difference demonstrated between the 2 kidneys based on the histopathological report shows that the healing process is capable of improving severe to mild alterations within a one-week time frame. Two weeks after the surgery, only minor changes were observed, suggesting that even temperature increases above the threshold can be tolerated regarding renal damage.