Biologic and Mechanical Stability of Screw-Retained Layered Zirconia Crowns Bonded to CAD/CAM Titanium Abutments Using Angulated Screw Access: A Prospective Closed Cohort Study.
{"title":"Biologic and Mechanical Stability of Screw-Retained Layered Zirconia Crowns Bonded to CAD/CAM Titanium Abutments Using Angulated Screw Access: A Prospective Closed Cohort Study.","authors":"Michael R Norton","doi":"10.11607/jomi.9856","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate hard and soft tissue response and mechanical integrity for screw-retained layered zirconia crowns bonded to titanium nitride-coated titanium (TiN) CAD/CAM abutments supported by implants at 1- and 2-year follow-ups. <b>Materials and Methods:</b> A total of 46 patients were restored with a total of 102 free-standing implant-supported layered zirconia crowns, which were bonded to their respective abutments in the dental laboratory and delivered as a one-piece screw-retained crown. Baseline, 1-year, and 2-year data were collated on pocket probing depth, bleeding on probing, marginal bone levels, and mechanical complications. <b>Results:</b> Of the 46 patients, 4 patients with one implant each were not followed-up. These patients were not included in the analysis. Of the remaining 98 implants, due to failed appointments during the global pandemic, soft tissue measurements were recorded for 94 implants at year 1 and 86 implants at year 2, with a mean buccal/lingual pocket probing depth of 1.80/1.95 mm and 2.09/2.17 mm, respectively. Mean bleeding on probing was 0.50 and 0.53 at 1 and 2 years, which represents somewhere between no bleeding and a spot bleed according to the study protocol. Radiographic data were available for 74 implants at year 1 and 86 implants at year 2. The mean marginal bone change from baseline was +0.11 mm mesially and +0.19 mm distally at 1 year and +0.24 mm mesially and +0.16 mm distally at 2 years. The final bone level with respect to the reference point was +0.49 mm mesially and +0.19 mm distally at the end of the study period. Mechanical complications involving a slight misfit of the crown margin were recorded for one unit (1%), porcelain fracture for 16 units (16%), and a loss of preload for 12 units (12%) of < 5 Ncm (< 20% of initial preload). <b>Conclusion:</b> The biologic and mechanical stability of ceramic crowns bonded to CAD/CAM screw-retained abutments using angulated screw access was considered to be high, with overall bone gain, excellent soft tissue health, and only limited mechanical complications related to generally small fractures of the porcelain and a clinically insignificant loss of preload.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 1","pages":"37-45"},"PeriodicalIF":1.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9856","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To evaluate hard and soft tissue response and mechanical integrity for screw-retained layered zirconia crowns bonded to titanium nitride-coated titanium (TiN) CAD/CAM abutments supported by implants at 1- and 2-year follow-ups. Materials and Methods: A total of 46 patients were restored with a total of 102 free-standing implant-supported layered zirconia crowns, which were bonded to their respective abutments in the dental laboratory and delivered as a one-piece screw-retained crown. Baseline, 1-year, and 2-year data were collated on pocket probing depth, bleeding on probing, marginal bone levels, and mechanical complications. Results: Of the 46 patients, 4 patients with one implant each were not followed-up. These patients were not included in the analysis. Of the remaining 98 implants, due to failed appointments during the global pandemic, soft tissue measurements were recorded for 94 implants at year 1 and 86 implants at year 2, with a mean buccal/lingual pocket probing depth of 1.80/1.95 mm and 2.09/2.17 mm, respectively. Mean bleeding on probing was 0.50 and 0.53 at 1 and 2 years, which represents somewhere between no bleeding and a spot bleed according to the study protocol. Radiographic data were available for 74 implants at year 1 and 86 implants at year 2. The mean marginal bone change from baseline was +0.11 mm mesially and +0.19 mm distally at 1 year and +0.24 mm mesially and +0.16 mm distally at 2 years. The final bone level with respect to the reference point was +0.49 mm mesially and +0.19 mm distally at the end of the study period. Mechanical complications involving a slight misfit of the crown margin were recorded for one unit (1%), porcelain fracture for 16 units (16%), and a loss of preload for 12 units (12%) of < 5 Ncm (< 20% of initial preload). Conclusion: The biologic and mechanical stability of ceramic crowns bonded to CAD/CAM screw-retained abutments using angulated screw access was considered to be high, with overall bone gain, excellent soft tissue health, and only limited mechanical complications related to generally small fractures of the porcelain and a clinically insignificant loss of preload.
期刊介绍:
Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786
ISSN (Online): 1942-4434
This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.