Local Diagnostic Reference Levels for Common Adult Computed Tomography Procedures in Addis Ababa.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2023-04-01 DOI:10.1177/15593258231171492
Seife Teferi Dellie, Ambaye Fisehaw Tesfaw, Marema Jebessa Kumsa, Birhanu Turi Tolawak
{"title":"Local Diagnostic Reference Levels for Common Adult Computed Tomography Procedures in Addis Ababa.","authors":"Seife Teferi Dellie,&nbsp;Ambaye Fisehaw Tesfaw,&nbsp;Marema Jebessa Kumsa,&nbsp;Birhanu Turi Tolawak","doi":"10.1177/15593258231171492","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Computed Tomography has become the major source of population exposure in diagnostic x-rays. This concerned issue will be resolved by stetting Local Diagnostic Reference Levels.</p><p><strong>Objectives: </strong>The main objective of this study is to assess dose indicators for the establishment of Local Diagnostic Reference Levels.</p><p><strong>Materials and methods: </strong><i>A</i> prospective cross-sectional study design was conducted on 8 public and private hospitals performing CT examinations. A total of 725 adult patients who underwent abdominopelvic, chest, and head CT examinations were evaluated from October 2021 to March 2022. Patients' demography, exposure parameters, and dose descriptors were collected. The minimum, maximum, mean, median, and third quartile values were analyzed using <i>SPSS software version 26.</i> Finally, the third <i>quartile values of collected</i> data were compared with national and international values.</p><p><strong>Results: </strong>The third quartile values obtained from median of volumetric <i>computed tomography dose index</i> (mGy) and <i>dose length product</i> (mGy.cm) which are considered as local DRLs for head, chest, and abdominopelvic CT examination, respectively, were 53 mGy, 14 mGy and 13 mGy<b>;</b> 1307 mGy.cm, 575 mGy.cm, and 932 mGy.cm.</p><p><strong>Conclusion: </strong>The results of this study showed that practices of CT imaging in both public and private hospitals in Addis Ababa were comparable to other national and international values.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/df/10.1177_15593258231171492.PMC10123899.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15593258231171492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Computed Tomography has become the major source of population exposure in diagnostic x-rays. This concerned issue will be resolved by stetting Local Diagnostic Reference Levels.

Objectives: The main objective of this study is to assess dose indicators for the establishment of Local Diagnostic Reference Levels.

Materials and methods: A prospective cross-sectional study design was conducted on 8 public and private hospitals performing CT examinations. A total of 725 adult patients who underwent abdominopelvic, chest, and head CT examinations were evaluated from October 2021 to March 2022. Patients' demography, exposure parameters, and dose descriptors were collected. The minimum, maximum, mean, median, and third quartile values were analyzed using SPSS software version 26. Finally, the third quartile values of collected data were compared with national and international values.

Results: The third quartile values obtained from median of volumetric computed tomography dose index (mGy) and dose length product (mGy.cm) which are considered as local DRLs for head, chest, and abdominopelvic CT examination, respectively, were 53 mGy, 14 mGy and 13 mGy; 1307 mGy.cm, 575 mGy.cm, and 932 mGy.cm.

Conclusion: The results of this study showed that practices of CT imaging in both public and private hospitals in Addis Ababa were comparable to other national and international values.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
亚的斯亚贝巴普通成人计算机断层扫描程序的本地诊断参考水平。
背景:计算机断层扫描已成为诊断x射线人群暴露的主要来源。这个问题可以通过设置本地诊断参考级别来解决。目的:本研究的主要目的是评估建立当地诊断参考水平的剂量指标。材料与方法:采用前瞻性横断面研究设计,对8家进行CT检查的公立和私立医院进行研究。从2021年10月到2022年3月,共有725名成年患者接受了腹部、骨盆、胸部和头部CT检查。收集患者的人口学、暴露参数和剂量描述符。最小值、最大值、平均值、中位数和第三四分位数值采用SPSS软件26进行分析。最后,将收集数据的第三个四分位数值与国内和国际值进行比较。结果:头颅、胸部、骨盆CT局部drl的体积CT剂量指数(mGy)和剂量长度乘积(mGy.cm)中位数的第三四分位数值分别为53 mGy、14 mGy和13 mGy;1307 mGy。厘米,575mgy。结论:本研究结果表明,亚的斯亚贝巴公立和私立医院的CT成像实践与其他国家和国际水平相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1