{"title":"Measurement of Anti-Mullerian Hormone: Preliminary Evaluation of an ABEI-Based Fully Automated Immunoassay.","authors":"Damien Gruson,&nbsp;Akdim Siham,&nbsp;Catherine Fillée","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The added value of Anti-Müllerian hormone (AMH) measurement is recognized for several clinical applications such as assessment of the ovarian reserve, monitoring of <i>in vitro</i> fertilization protocol or in the field of oncofertility. Our study objective was to determine the performances of a novel fully automated chemiluminescent assay for AMH testing.</p><p><strong>Methods: </strong>We evaluated the performances of the Maglumi<sup>®</sup> 800 AMH chemiluminescent immunoassay that applies N-(4-Aminobutyl)-N-ethylisoluminol (ABEI) labels. Assay imprecision was assessed with two levels of control materials. Method comparison was performed with an ultrasensitive AMH ELISA assay (Ansh Laboratories, Inc, Webster, TX, USA) with 88 patients' samples.</p><p><strong>Results: </strong>The within-run and between-run coefficients of variation (CVs) were below <i>3%</i> for both low and high internal quality controls. The automated and ELISA methods were significantly correlated. Bland-Altman plot evidenced a bias between the methods with a mean bias of 0.6 ng/mL.</p><p><strong>Conclusions: </strong>Our preliminary evaluation showed overall good analytical performances for the Maglumi<sup>®</sup> AMH fully automated immunoassay and good concordance with a routinely used assay.</p>","PeriodicalId":37192,"journal":{"name":"Electronic Journal of the International Federation of Clinical Chemistry and Laboratory Medicine","volume":"34 1","pages":"4-9"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/74/a1/ejifcc-34-004.PMC10131241.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electronic Journal of the International Federation of Clinical Chemistry and Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The added value of Anti-Müllerian hormone (AMH) measurement is recognized for several clinical applications such as assessment of the ovarian reserve, monitoring of in vitro fertilization protocol or in the field of oncofertility. Our study objective was to determine the performances of a novel fully automated chemiluminescent assay for AMH testing.

Methods: We evaluated the performances of the Maglumi® 800 AMH chemiluminescent immunoassay that applies N-(4-Aminobutyl)-N-ethylisoluminol (ABEI) labels. Assay imprecision was assessed with two levels of control materials. Method comparison was performed with an ultrasensitive AMH ELISA assay (Ansh Laboratories, Inc, Webster, TX, USA) with 88 patients' samples.

Results: The within-run and between-run coefficients of variation (CVs) were below 3% for both low and high internal quality controls. The automated and ELISA methods were significantly correlated. Bland-Altman plot evidenced a bias between the methods with a mean bias of 0.6 ng/mL.

Conclusions: Our preliminary evaluation showed overall good analytical performances for the Maglumi® AMH fully automated immunoassay and good concordance with a routinely used assay.

Abstract Image

Abstract Image

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
抗苗勒管激素的测定:基于abei的全自动免疫分析法的初步评价。
背景:抗勒氏激素(AMH)测定的附加价值在卵巢储备评估、体外受精方案监测或肿瘤生育领域等临床应用中得到认可。我们的研究目的是确定一种新型全自动化学发光法检测AMH的性能。方法:采用N-(4-氨基丁基)-N-乙基异亮醇(ABEI)标记,评价Maglumi®800 AMH化学发光免疫分析法的性能。用两级对照品评价测定不精密度。方法采用超灵敏AMH酶联免疫吸附试验(Ansh Laboratories, Inc, Webster, TX, USA)对88例患者进行比较。结果:低、高内控的批内、批间变异系数(CVs)均小于3%。自动化检测方法与ELISA检测方法相关性显著。Bland-Altman图证明了两种方法之间的偏差,平均偏差为0.6 ng/mL。结论:我们的初步评估显示,Maglumi®AMH全自动免疫分析总体上具有良好的分析性能,并且与常规使用的分析具有良好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
相关文献
The number of intratumoral dendritic cells and ζ-chain expression in T cells as prognostic and survival biomarkers in patients with oral carcinoma
IF 6.2 2区 医学CancerPub Date : 2001-05-31 DOI: 10.1002/1097-0142(20010601)91:11<2136::AID-CNCR1242>3.0.CO;2-Q
Torsten E. Reichert M.D., Ph.D., Claudia Scheuer Ph.D., Roger Day Sc.D., Wilfried Wagner M.D., Ph.D., Theresa L. Whiteside Ph.D.
Intratumoral T cells, recurrence, and survival in epithelial ovarian cancer.
IF 158.5 1区 医学New England Journal of MedicinePub Date : 2003-01-16 DOI: 10.1056/NEJMoa020177
Lin Zhang, Jose R Conejo-Garcia, Dionyssios Katsaros, Phyllis A Gimotty, Marco Massobrio, Giorgia Regnani, Antonis Makrigiannakis, Heidi Gray, Katia Schlienger, Michael N Liebman, Stephen C Rubin, George Coukos
Intratumoral T cells and survival in epithelial ovarian cancer.
IF 0.4 4区 医学National Medical Journal of IndiaPub Date : 2003-05-01 DOI:
Jeremy L Pautu, Lalit Kumar
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
0
期刊最新文献
Abnormal Urine Drug Screens in Pregnancy- Opportunity for Laboratory Stewardship. Biomarkers for Harmful Alcohol Use should be Reliable, Standardised, and Traceable: Only the CDT reference method has been approved by JCTLM and IFCC. A Rare Pure Calcite Urolithiasis Confirmed by Infrared Spectroscopy. Highlights from the Manifesto on Early Detection and Diagnosis of Cardiovascular Disease: The Role of Laboratory Tests and Emerging Technologies. Implosion of Grail's Galleri Cancer Screening Test?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1