Comparison of Stress Distribution Among Standard Dental Implants Placed in Grafted Bone, Zygomatic Implants, and Subperiosteal Implants in the Atrophic Edentulous Maxilla: 3D Finite Element Analysis.

IF 1.7 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Oral & Maxillofacial Implants Pub Date : 2023-03-01 DOI:10.11607/jomi.9987
H Gözde Keleş, Çiğdem Karaca
{"title":"Comparison of Stress Distribution Among Standard Dental Implants Placed in Grafted Bone, Zygomatic Implants, and Subperiosteal Implants in the Atrophic Edentulous Maxilla: 3D Finite Element Analysis.","authors":"H Gözde Keleş,&nbsp;Çiğdem Karaca","doi":"10.11607/jomi.9987","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To compare the biomechanical behaviors of different surgical options that are preferred for implant-supported fixed prosthetic rehabilitation of the atrophic edentulous maxilla. <b>Materials and Methods:</b> A 3D finite element analysis (FEA) model was generated from the computed tomography data of a patient with an atrophic edentulous maxilla. Four scenarios were created in the atrophic maxilla. In model 1, the maxilla was reconstructed with an onlay bone graft harvested from the anterior iliac crest, and sinus augmentation procedures were performed. Standard dental implants were placed in the lateral incisor, first premolar, and first molar regions on each side. In model 2, the anterior part of the atrophic maxilla was reconstructed with an onlay bone graft harvested from the mandibular ramus, and zygomatic implants were placed in the posterior part of the maxilla. In models 3 and 4, two-piece subperiosteal implants made of titanium and polyether ether ketone (PEEK) materials, respectively, were placed in the atrophic maxilla. All implants were loaded with 150-N and 50-N forces in vertical and lateral directions, respectively. Stress accumulation on bones, implants, abutments, and prosthetic frameworks was investigated. <b>Results:</b> The tensile stress in both cortical and trabecular bone was highest in the iliac bone grafting group under vertical loading. The compressive stress in both cortical and trabecular bone was the highest in the PEEK subperiosteal implant model, and the compressive stress value on the trabecular bone exceeded the strength of the trabecular bone. The highest von Mises stress in the implants was obtained in the iliac bone grafting group under vertical loading. The highest stress value in the abutments was detected for the titanium subperiosteal implant. The highest von Mises stress in the prosthetic framework was detected in the titanium subperiosteal implant group, under both vertical and lateral loading. <b>Conclusion:</b> Based on the stress accumulation results of the four different scenarios, it can be seen that there is no ideal treatment modality for the fixed implant-supported prosthetic rehabilitation of the atrophic edentulous maxilla. Various intraoperative and prosthetic modifications are suggested to decrease the risk of biomechanical complications during long-term follow-up.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 2","pages":"347-356"},"PeriodicalIF":1.7000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9987","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

Abstract

Purpose: To compare the biomechanical behaviors of different surgical options that are preferred for implant-supported fixed prosthetic rehabilitation of the atrophic edentulous maxilla. Materials and Methods: A 3D finite element analysis (FEA) model was generated from the computed tomography data of a patient with an atrophic edentulous maxilla. Four scenarios were created in the atrophic maxilla. In model 1, the maxilla was reconstructed with an onlay bone graft harvested from the anterior iliac crest, and sinus augmentation procedures were performed. Standard dental implants were placed in the lateral incisor, first premolar, and first molar regions on each side. In model 2, the anterior part of the atrophic maxilla was reconstructed with an onlay bone graft harvested from the mandibular ramus, and zygomatic implants were placed in the posterior part of the maxilla. In models 3 and 4, two-piece subperiosteal implants made of titanium and polyether ether ketone (PEEK) materials, respectively, were placed in the atrophic maxilla. All implants were loaded with 150-N and 50-N forces in vertical and lateral directions, respectively. Stress accumulation on bones, implants, abutments, and prosthetic frameworks was investigated. Results: The tensile stress in both cortical and trabecular bone was highest in the iliac bone grafting group under vertical loading. The compressive stress in both cortical and trabecular bone was the highest in the PEEK subperiosteal implant model, and the compressive stress value on the trabecular bone exceeded the strength of the trabecular bone. The highest von Mises stress in the implants was obtained in the iliac bone grafting group under vertical loading. The highest stress value in the abutments was detected for the titanium subperiosteal implant. The highest von Mises stress in the prosthetic framework was detected in the titanium subperiosteal implant group, under both vertical and lateral loading. Conclusion: Based on the stress accumulation results of the four different scenarios, it can be seen that there is no ideal treatment modality for the fixed implant-supported prosthetic rehabilitation of the atrophic edentulous maxilla. Various intraoperative and prosthetic modifications are suggested to decrease the risk of biomechanical complications during long-term follow-up.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
萎缩性无牙上颌植骨、颧骨和骨膜下种植体的应力分布比较:三维有限元分析。
目的:比较不同术式对萎缩无牙上颌种植固定修复的生物力学行为。材料与方法:利用上颌无牙萎缩患者的计算机断层扫描数据建立三维有限元分析模型。在萎缩的上颌骨中创造了四种情景。在模型1中,用从髂前嵴取下的骨块重建上颌骨,并进行鼻窦增强手术。标准牙种植体放置在侧切牙、第一前磨牙和每侧第一磨牙区域。在模型2中,用从下颌分支取下的骨块重建萎缩的上颌前部,并在上颌后部放置颧种植体。在模型3和4中,在萎缩的上颌骨中分别放置钛和聚醚醚酮(PEEK)材料制成的两片式骨膜下种植体。所有种植体分别在垂直和横向施加150-N和50-N的力。研究了骨、种植体、基台和假体框架上的应力积累。结果:髂骨移植组在垂直载荷作用下骨皮质和骨小梁的拉伸应力均最大。PEEK骨膜下种植体模型皮质骨和小梁骨的压应力均最高,小梁骨的压应力值超过了小梁骨的强度。垂直载荷下髂骨移植组的von Mises应力最大。钛骨膜下种植体的基台应力值最高。在垂直和侧向载荷下,骨膜下钛种植体组假体框架的von Mises应力最高。结论:基于四种不同情况下的应力积累结果,可以看出萎缩性无牙上颌骨的固定种植体支持修复没有理想的治疗方式。建议在长期随访中进行各种术中和假体修改以减少生物力学并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.30
自引率
5.00%
发文量
115
审稿时长
6 months
期刊介绍: Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786 ISSN (Online): 1942-4434 This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.
期刊最新文献
Peri-implant Parameters of Dental Implants Inserted in Prefabricated Microvascular Fibular Flaps: A Retrospective Study. Different Surgical Techniques in the All-on-4 Treatment Concept: Evaluation of the Stress Distribution Created in Implant and Peripheral Bone with Finite Element Analysis. Augmentation of Peri-implant Keratinized Mucosa Using a Combination of Free Gingival Graft Strip with Xenogeneic Collagen Matrix or Free Gingival Graft Alone: A Randomized Controlled Study. Efficacy of Labial Split-Thickness Eversion Periosteoplasty for Soft Tissue Management in Posterior Mandibular Horizontal Ridge Augmentation Procedures: A Prospective Clinical Study. Porcine Resorbable Collagen Matrix Shows Good Incorporation of Liquid Platelet-Rich Fibrin In Vitro.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1