Lung Ultrasound and Caval Indices to Assess Volume Status in Maintenance Hemodialysis Patients.

Mujtaba Z Al-Saray, Ala Ali
{"title":"Lung Ultrasound and Caval Indices to Assess Volume Status in Maintenance Hemodialysis Patients.","authors":"Mujtaba Z Al-Saray,&nbsp;Ala Ali","doi":"10.24908/pocus.v8i1.15802","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Volume overload is common in end stage kidney disease (ESKD) and dialysis patients. Hence, the need for objective tools to detect such volume excess. Point of care ultrasound (POCUS) is a goal-directed, bedside examination to answer such a specific diagnostic question. <b>Methods:</b> One hundred Iraqi adult hemodialysis patients were recruited from February 1 to May 31, 2022. Primary clinical, dialysis data, and prescriptions were recorded. A nephrologist performed a POCUS examination after the last dialysis session of the week. In addition, an ultrasound examination of the chest was performed to detect B-lines and pleural effusion. Caval parameters included inferior vena cava (IVC) diameter and collapsibility index. <b>Results:</b> The mean age of the study group was 51.48 ± 14.6 years, with 53% males. The mean interdialytic weight gain was 2.74 ± 1.15 Kg. Lower limb edema and pleural effusion were present in 33% and 27%, respectively. Forty-seven percent of patients had >3 B-lines on lung ultrasound with a range of 12. Forty-three percent of patients had an IVC diameter of >2 cm, and 93% had <50% IVC collapsibility. In total, 97% of patients had evidence of excess volume by ultrasound criteria. IVC collapsibility index was the most prevalent sign of excess volume (93%). Patients without lower limb edema and pleural effusion had positive B-lines in 38.8% and 38.3%, an IVC diameter >2 cm in 46.2% and 38.3%, and IVC collapsibility <50% in 89.5% and 95.8% respectively. <b>Conclusion:</b> Iraqi maintenance hemodialysis patients are volume overloaded, which warrants proper intervention for detection and dialysis management. POCUS is a useful and easily performed technique to assess the volume status.</p>","PeriodicalId":74470,"journal":{"name":"POCUS journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155735/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"POCUS journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24908/pocus.v8i1.15802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Volume overload is common in end stage kidney disease (ESKD) and dialysis patients. Hence, the need for objective tools to detect such volume excess. Point of care ultrasound (POCUS) is a goal-directed, bedside examination to answer such a specific diagnostic question. Methods: One hundred Iraqi adult hemodialysis patients were recruited from February 1 to May 31, 2022. Primary clinical, dialysis data, and prescriptions were recorded. A nephrologist performed a POCUS examination after the last dialysis session of the week. In addition, an ultrasound examination of the chest was performed to detect B-lines and pleural effusion. Caval parameters included inferior vena cava (IVC) diameter and collapsibility index. Results: The mean age of the study group was 51.48 ± 14.6 years, with 53% males. The mean interdialytic weight gain was 2.74 ± 1.15 Kg. Lower limb edema and pleural effusion were present in 33% and 27%, respectively. Forty-seven percent of patients had >3 B-lines on lung ultrasound with a range of 12. Forty-three percent of patients had an IVC diameter of >2 cm, and 93% had <50% IVC collapsibility. In total, 97% of patients had evidence of excess volume by ultrasound criteria. IVC collapsibility index was the most prevalent sign of excess volume (93%). Patients without lower limb edema and pleural effusion had positive B-lines in 38.8% and 38.3%, an IVC diameter >2 cm in 46.2% and 38.3%, and IVC collapsibility <50% in 89.5% and 95.8% respectively. Conclusion: Iraqi maintenance hemodialysis patients are volume overloaded, which warrants proper intervention for detection and dialysis management. POCUS is a useful and easily performed technique to assess the volume status.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
维持性血液透析患者肺超声和腔静脉指标评估容量状况。
背景:容量超载在终末期肾脏疾病(ESKD)和透析患者中很常见。因此,需要客观的工具来检测这种体积过剩。护理点超声(POCUS)是一种目标导向的床边检查,以回答这样一个特定的诊断问题。方法:于2022年2月1日至5月31日招募伊拉克成年血液透析患者100例。记录主要临床、透析资料和处方。肾科医生在本周最后一次透析后进行了POCUS检查。此外,进行胸部超声检查以检测b线和胸腔积液。下腔静脉参数包括下腔静脉(IVC)直径和溃散指数。结果:研究组平均年龄51.48±14.6岁,男性占53%。平均透析期体重增加2.74±1.15 Kg。下肢水肿和胸腔积液分别占33%和27%。47%的患者在肺超声上有>3个b线,范围为12。结论:伊拉克维持性血液透析患者存在容量超载,需要采取适当的干预措施进行检测和透析管理。POCUS是一种有用且易于执行的评估体积状态的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Application of Point of Care Ultrasound to Screen for Pulmonary Hypertension: A Narrative Review VExUS to Guide Ultrafiltration in Hemodialysis: Exploring a Novel Dimension of Point of Care Ultrasound Best Practices for Point of Care Ultrasound: An Interdisciplinary Expert Consensus Return of the Living Dead Gut – A Case Report of Ischemic Colitis Identified on Point of Care Ultrasound Emergency Physician Performed Ultrasound-Guided Abdominal Paracentesis: A Retrospective Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1