Effects of Ballista and Kilroy Springs on Palatally Impacted Canines: A Finite Element Model Analysis.

IF 0.8 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Turkish Journal of Orthodontics Pub Date : 2023-03-21 DOI:10.4274/TurkJOrthod.2022.2022.10
Ecem Nagihan Başer, Nevin Kaptan Akar, Gülşilay Sayar
{"title":"Effects of Ballista and Kilroy Springs on Palatally Impacted Canines: A Finite Element Model Analysis.","authors":"Ecem Nagihan Başer,&nbsp;Nevin Kaptan Akar,&nbsp;Gülşilay Sayar","doi":"10.4274/TurkJOrthod.2022.2022.10","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study evaluated the stress distribution and displacement on impacted maxillary canines and their adjacent teeth of orthodontic forced eruption using Ballista and Kilroy springs by finite element model (FEM) analysis.</p><p><strong>Methods: </strong>Two different FEMs applying the same force level on an impacted canine tooth (Model 1: Ballista spring, Model 2: Kilroy spring) were conducted using FEM analysis and the principal stresses, von Mises stresses, and displacements were evaluated.</p><p><strong>Results: </strong>Von Mises values at the cusp tip of impacted canines were measured as 0.009896 N/mm² in the Ballista model and 0.015334 N/mm² in the Kilroy model. The highest value was measured in the buccal apex of the first premolar in both spring designs. The extrusion was observed in Ballista, and intrusion was observed in the Kilroy model at the apex of the first premolar. The Ballista model showed the highest value (0.003642 N/mm²) at the buccal tip of the first premolar, while in the Kilroy model, the highest measurement (0.002989 N/mm²) was shown at the incisal edge of the lateral tooth.</p><p><strong>Conclusion: </strong>Von Mises stress values were higher in the Kilroy model at the cusp tip and apical part of the impacted tooth than that in the Ballista model. The highest von Mises stress values were concentrated on the buccal root apex of the first premolar in both models. Although the amount of force applied by the springs was the same, the stress values were different depending on the spring design.</p>","PeriodicalId":37013,"journal":{"name":"Turkish Journal of Orthodontics","volume":"36 1","pages":"30-38"},"PeriodicalIF":0.8000,"publicationDate":"2023-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ad/97/tjo-36-30.PMC10140656.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/TurkJOrthod.2022.2022.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Objective: This study evaluated the stress distribution and displacement on impacted maxillary canines and their adjacent teeth of orthodontic forced eruption using Ballista and Kilroy springs by finite element model (FEM) analysis.

Methods: Two different FEMs applying the same force level on an impacted canine tooth (Model 1: Ballista spring, Model 2: Kilroy spring) were conducted using FEM analysis and the principal stresses, von Mises stresses, and displacements were evaluated.

Results: Von Mises values at the cusp tip of impacted canines were measured as 0.009896 N/mm² in the Ballista model and 0.015334 N/mm² in the Kilroy model. The highest value was measured in the buccal apex of the first premolar in both spring designs. The extrusion was observed in Ballista, and intrusion was observed in the Kilroy model at the apex of the first premolar. The Ballista model showed the highest value (0.003642 N/mm²) at the buccal tip of the first premolar, while in the Kilroy model, the highest measurement (0.002989 N/mm²) was shown at the incisal edge of the lateral tooth.

Conclusion: Von Mises stress values were higher in the Kilroy model at the cusp tip and apical part of the impacted tooth than that in the Ballista model. The highest von Mises stress values were concentrated on the buccal root apex of the first premolar in both models. Although the amount of force applied by the springs was the same, the stress values were different depending on the spring design.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
弹弓和基罗伊弹簧对腭碰撞犬的影响:有限元模型分析。
目的:采用有限元模型(FEM)分析Ballista和Kilroy弹簧对正畸强制萌牙阻生上颌牙及其邻牙的应力分布和位移。方法:采用两种不同的有限元分析方法(模型1:Ballista弹簧,模型2:Kilroy弹簧),对同一水平的力作用于阻合的犬牙进行有限元分析,评估主应力、von Mises应力和位移。结果:Ballista模型和Kilroy模型测得碰撞犬尖尖处Von Mises值分别为0.009896 N/mm²和0.015334 N/mm²。在两种弹簧设计中,在第一前磨牙的颊尖处测量到的值最高。Ballista模型在第一前磨牙尖部观察到挤压,Kilroy模型在第一前磨牙尖部观察到侵入。Ballista模型在第一前磨牙颊尖处测量值最高(0.003642 N/mm²),Kilroy模型在侧牙切缘处测量值最高(0.002989 N/mm²)。结论:Kilroy模型阻生牙尖、尖部的Von Mises应力值高于Ballista模型。两种模型的von Mises应力值均集中在第一前磨牙的颊根尖处。虽然弹簧施加的力是相同的,但应力值因弹簧设计而异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Turkish Journal of Orthodontics
Turkish Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.10
自引率
9.10%
发文量
34
期刊最新文献
Accuracy of 3D Printer Technologies Using Digital Dental Models. Comparing the Impact of Titanium and Stainless Steel Retainers on Lower Incisor Stability, Periodontal Health, and Retainer Survival: A Preliminary Study. Comparison of the Effects of Fixed and Removable Functional Orthodontic Treatment on the Mandibular Trabecular Bone in Fractal Analysis. Effects of Emotional States on Reproducibilities of Rest Position, Social and Spontaneous Smiles, and Speech. Erratum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1