Fracture Resistance of CAD/CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging.
{"title":"Fracture Resistance of CAD/CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging.","authors":"Ayşe Yavuz, Emine Begüm Büyükerkmen","doi":"10.11607/jomi.9693","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate the effect of chewing simulation and thermocyclic aging on the fracture resistance of CAD/CAM monolithic zirconia crowns supported by titanium and Ti-base abutments. <b>Materials and Methods:</b> Two implant abutment groups-titanium (Ti) and titanium base (Ti-base; Medentika)-were used. A total of 40 mandibular first molar CAD/CAM monolithic zirconia crowns (Vita YZ T) were fabricated, then cemented onto the abutments with Panavia V5. Each abutment group was divided into two subgroups (n = 10). The Ti and Ti-base groups were subjected to a single load until fracture, and the Ti/CT and Ti-base/CT groups (CT: chewing simulation and thermocyclic aging) underwent chewing simulation (1.2 × 10<sup>6</sup> cycles × 50 N load, 1.4 Hz) and thermocylic aging (3,911 cycles/5°C to 55°C). The fracture resistances of the crowns were tested with a universal testing machine (1 mm/minute). Shapiro-Wilk and one-way ANOVA test were used for statistical analysis (<i>P</i> = .05). <b>Results:</b> The survival rates after chewing simulation and thermocyclic aging were 100% for both CT groups. The fracture resistance values (mean ± SD) of the groups were as follows: Ti = 1,718.18 ± 331.06 N, Ti-base = 1,713.53 ± 233.24 N, Ti/CT = 1,664.82 ± 188.62 N, and Ti-base/CT = 1,551.28 ± 344.79 N. According to one-way ANOVA test results, there was no statistically significant difference between the four groups (<i>P</i> = .526). <b>Conclusion:</b> CAD/CAM monolithic zirconia crowns supported by Ti-base or titanium abutments were found to have sufficient fracture resistance in the treatment of an absent single posterior tooth. However, more in vitro and clinical studies are required to evaluate the long-term performance of Ti-base abutments and CAD/CAM zirconia crowns.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9693","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To evaluate the effect of chewing simulation and thermocyclic aging on the fracture resistance of CAD/CAM monolithic zirconia crowns supported by titanium and Ti-base abutments. Materials and Methods: Two implant abutment groups-titanium (Ti) and titanium base (Ti-base; Medentika)-were used. A total of 40 mandibular first molar CAD/CAM monolithic zirconia crowns (Vita YZ T) were fabricated, then cemented onto the abutments with Panavia V5. Each abutment group was divided into two subgroups (n = 10). The Ti and Ti-base groups were subjected to a single load until fracture, and the Ti/CT and Ti-base/CT groups (CT: chewing simulation and thermocyclic aging) underwent chewing simulation (1.2 × 106 cycles × 50 N load, 1.4 Hz) and thermocylic aging (3,911 cycles/5°C to 55°C). The fracture resistances of the crowns were tested with a universal testing machine (1 mm/minute). Shapiro-Wilk and one-way ANOVA test were used for statistical analysis (P = .05). Results: The survival rates after chewing simulation and thermocyclic aging were 100% for both CT groups. The fracture resistance values (mean ± SD) of the groups were as follows: Ti = 1,718.18 ± 331.06 N, Ti-base = 1,713.53 ± 233.24 N, Ti/CT = 1,664.82 ± 188.62 N, and Ti-base/CT = 1,551.28 ± 344.79 N. According to one-way ANOVA test results, there was no statistically significant difference between the four groups (P = .526). Conclusion: CAD/CAM monolithic zirconia crowns supported by Ti-base or titanium abutments were found to have sufficient fracture resistance in the treatment of an absent single posterior tooth. However, more in vitro and clinical studies are required to evaluate the long-term performance of Ti-base abutments and CAD/CAM zirconia crowns.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.