Javier Masquijo, Cristian Artigas, Juan Carlos Hernández Bueno, Matías Sepúlveda, Jamil Soni, Weverley Valenza, Faris Fazal, Apurva S Shah
{"title":"Surgical correction of cubitus varus in children with a lateral closing-wedge osteotomy: a comparison between two different techniques.","authors":"Javier Masquijo, Cristian Artigas, Juan Carlos Hernández Bueno, Matías Sepúlveda, Jamil Soni, Weverley Valenza, Faris Fazal, Apurva S Shah","doi":"10.1097/BPB.0000000000001092","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The primary objective of the present study is to compare the radiographic outcomes and complications of two different techniques for lateral closing-wedge osteotomy in pediatric patients with cubitus varus.</p><p><strong>Methods: </strong>We retrospectively identified patients treated at five tertiary care institutions: 17 underwent the Kirschner-wire (KW) technique, and 15 patients were treated with the mini external fixator (MEF) technique. Demographic data, previous treatment, pre- and postoperative carrying angle (CA), complications and additional procedures were recorded. Radiographic evaluation included assessment of the humerus-elbow-wrist angle (HEW), and the lateral prominence index (LPI).</p><p><strong>Results: </strong>Patients treated with both KW and MEF achieved significant improvements in clinical alignment (mean pre-op CA -16 ± 6.1 degrees to mean post-op 8.9 ± 5.3 degrees, P < 0.001). There were no differences in final radiographic alignment or radiographic union time; however, time to achieve full elbow motion was faster in the MEF group (13.6 versus 34.3 weeks, P = 0.4547). Two patients (11.8%) in the KW group experienced complications, including one superficial infection and one failed correction that required unplanned revision surgery. Eleven patients in the MEF group underwent a planned second surgical procedure for hardware removal.</p><p><strong>Conclusions: </strong>Both fixation techniques are effective at correcting cubitus varus in the pediatric population. The MEF technique may have the advantage of shorter recovery of elbow range of motion but may require sedation for hardware removal. The KW technique may present a slightly higher complication rate.</p>","PeriodicalId":50092,"journal":{"name":"Journal of Pediatric Orthopaedics-Part B","volume":" ","pages":"167-173"},"PeriodicalIF":0.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics-Part B","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000001092","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/8 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The primary objective of the present study is to compare the radiographic outcomes and complications of two different techniques for lateral closing-wedge osteotomy in pediatric patients with cubitus varus.
Methods: We retrospectively identified patients treated at five tertiary care institutions: 17 underwent the Kirschner-wire (KW) technique, and 15 patients were treated with the mini external fixator (MEF) technique. Demographic data, previous treatment, pre- and postoperative carrying angle (CA), complications and additional procedures were recorded. Radiographic evaluation included assessment of the humerus-elbow-wrist angle (HEW), and the lateral prominence index (LPI).
Results: Patients treated with both KW and MEF achieved significant improvements in clinical alignment (mean pre-op CA -16 ± 6.1 degrees to mean post-op 8.9 ± 5.3 degrees, P < 0.001). There were no differences in final radiographic alignment or radiographic union time; however, time to achieve full elbow motion was faster in the MEF group (13.6 versus 34.3 weeks, P = 0.4547). Two patients (11.8%) in the KW group experienced complications, including one superficial infection and one failed correction that required unplanned revision surgery. Eleven patients in the MEF group underwent a planned second surgical procedure for hardware removal.
Conclusions: Both fixation techniques are effective at correcting cubitus varus in the pediatric population. The MEF technique may have the advantage of shorter recovery of elbow range of motion but may require sedation for hardware removal. The KW technique may present a slightly higher complication rate.
期刊介绍:
The journal highlights important recent developments from the world''s leading clinical and research institutions. The journal publishes peer-reviewed papers on the diagnosis and treatment of pediatric orthopedic disorders.
It is the official journal of IFPOS (International Federation of Paediatric Orthopaedic Societies).
Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.