{"title":"Decreased Complication Rate Using Partially Threaded Compared With Fully Threaded Compression Screws in 4 Corner Arthrodesis: A Retrospective Study.","authors":"Tammam Hanna, Nathan Smith, Chibuzo Akalonu, Jack Simmons, Priyanka V Nehete, Mark Dodson","doi":"10.1177/15589447231167883","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Scapho-lunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) of the wrist are the most common types of wrist arthritis. We compared the union rate and complication profile of patients with SLAC and SNAC wrist undergoing 4 corner arthrodesis with partially threaded or fully threaded headless compression screws.</p><p><strong>Methods: </strong>A single-center retrospective review was conducted to identify all patients treated for SLAC and SNAC with 4 corner fusion using headless compression screws from 2016 to 2021. A total of 33 patients undergoing surgery on 35 wrists were identified and included in the study. Demographics, comorbidities, complication profile, and radiographs were collected and compared between groups.</p><p><strong>Results: </strong>One hundred percent (16/16) of partially threaded and 84.2% (16/19) of fully threaded screws demonstrated union by minimum 10-week follow-up. The total complication rate (avascular necrosis of lunate, screw loosening, etc.) was 31.4%; 52.6% of wrists implanted with fully threaded screws experienced complications compared with a 6.3% complication rate with partially threaded screws. The difference was statistically significant between the 2 groups (<i>P</i> = .004).</p><p><strong>Conclusions: </strong>Four corner arthrodesis using antegrade compression screws is an effective, reproducible method to achieve fusion in the wrist. The use of fully threaded screws was associated with more complications than with partially threaded screws, although union rate was not significantly different. Future studies with larger sample sizes would be useful to fully elucidate differences between these 2 constructs.</p>","PeriodicalId":12902,"journal":{"name":"HAND","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11536756/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HAND","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15589447231167883","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Scapho-lunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) of the wrist are the most common types of wrist arthritis. We compared the union rate and complication profile of patients with SLAC and SNAC wrist undergoing 4 corner arthrodesis with partially threaded or fully threaded headless compression screws.

Methods: A single-center retrospective review was conducted to identify all patients treated for SLAC and SNAC with 4 corner fusion using headless compression screws from 2016 to 2021. A total of 33 patients undergoing surgery on 35 wrists were identified and included in the study. Demographics, comorbidities, complication profile, and radiographs were collected and compared between groups.

Results: One hundred percent (16/16) of partially threaded and 84.2% (16/19) of fully threaded screws demonstrated union by minimum 10-week follow-up. The total complication rate (avascular necrosis of lunate, screw loosening, etc.) was 31.4%; 52.6% of wrists implanted with fully threaded screws experienced complications compared with a 6.3% complication rate with partially threaded screws. The difference was statistically significant between the 2 groups (P = .004).

Conclusions: Four corner arthrodesis using antegrade compression screws is an effective, reproducible method to achieve fusion in the wrist. The use of fully threaded screws was associated with more complications than with partially threaded screws, although union rate was not significantly different. Future studies with larger sample sizes would be useful to fully elucidate differences between these 2 constructs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在四角关节置换术中使用部分螺纹加压螺钉比使用全螺纹加压螺钉降低并发症发生率:一项回顾性研究。
背景:腕关节的肩月状晚期塌陷(SLAC)和肩胛骨未愈合晚期塌陷(SNAC)是最常见的腕关节炎类型。我们比较了使用部分螺纹或完全螺纹无头加压螺钉进行四角关节置换术的 SLAC 和 SNAC 患者的结合率和并发症情况:方法: 对2016年至2021年期间使用无头加压螺钉进行4角融合术治疗的所有SLAC和SNAC患者进行了单中心回顾性研究。共有 33 名患者接受了 35 只手腕的手术并被纳入研究。研究人员收集了各组患者的人口统计学资料、合并症、并发症情况和X光片,并进行了比较:结果:在至少10周的随访中,100%(16/16)的部分螺纹螺钉和84.2%(16/19)的完全螺纹螺钉显示出结合。总并发症发生率(月骨血管性坏死、螺钉松动等)为31.4%;52.6%植入全螺纹螺钉的手腕出现并发症,而部分螺纹螺钉的并发症发生率为6.3%。两组之间的差异具有统计学意义(P = .004):结论:使用前向加压螺钉进行四角关节固定是实现腕关节融合的一种有效、可重复的方法。与部分螺纹螺钉相比,使用全螺纹螺钉的并发症更多,但骨结合率并无显著差异。未来样本量更大的研究将有助于全面阐明这两种结构之间的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
HAND
HAND Medicine-Surgery
CiteScore
3.30
自引率
0.00%
发文量
209
期刊介绍: HAND is the official journal of the American Association for Hand Surgery and is a peer-reviewed journal featuring articles written by clinicians worldwide presenting current research and clinical work in the field of hand surgery. It features articles related to all aspects of hand and upper extremity surgery and the post operative care and rehabilitation of the hand.
期刊最新文献
Early and Late Intrinsic Hand Muscle Reinnervation After End-to-Side AIN to Ulnar Motor Nerve Transfer. Generic Volar Locking Plate Use in Distal Radius Fractures: A Prospective Randomized Study to Evaluate Clinical Outcomes and Cost Reduction. Infections and Patient Satisfaction in WALANT Hand Surgery in a Hospital Procedure Room. Management Options and Clinical Outcomes After Flexor Tendon Ruptures Following Volar Plating of Distal Radius Fractures. Decreased Complication Rate Using Partially Threaded Compared With Fully Threaded Compression Screws in 4 Corner Arthrodesis: A Retrospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1