High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma.

IF 1.6 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS Assay and drug development technologies Pub Date : 2023-04-01 DOI:10.1089/adt.2022.113
Nikhil Agrawal, Amit Mittal
{"title":"High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma.","authors":"Nikhil Agrawal,&nbsp;Amit Mittal","doi":"10.1089/adt.2022.113","DOIUrl":null,"url":null,"abstract":"<p><p>A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C<sub>18</sub> Symmetry Shield (150 × 4.6 mm, 5.0 μm) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for <i>in vivo</i> and <i>ex vivo</i> autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.</p>","PeriodicalId":8586,"journal":{"name":"Assay and drug development technologies","volume":"21 3","pages":"110-125"},"PeriodicalIF":1.6000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Assay and drug development technologies","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/adt.2022.113","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C18 Symmetry Shield (150 × 4.6 mm, 5.0 μm) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for in vivo and ex vivo autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高通量超高效液相色谱-串联质谱法测定人血浆中阿托伐他汀及其活性代谢物的验证。
采用阿托伐他汀- d5 (ATR- d5)、2-羟基阿托伐他汀- d5 (2-ATR- d5)和4-羟基阿托伐他汀- d5 (4-ATR- d5)作为氘标记内标(istd),对一种高选择性、灵敏、坚固、快速的超高效液相色谱-串联质谱法(UPLC-MS/MS)进行了优化和验证,可可靠地定量测定人血浆中阿托伐他汀(ATR)及其活性代谢产物2-ATR和4-羟基阿托伐他汀(4-ATR- d5)。采用反相C18对称屏蔽柱(150 × 4.6 mm, 5.0 μm),流动相为乙腈:2 mm甲酸铵(pH-3.0) [65:35%v/v],流速为0.7 mL/min,等容模式色谱分离。采用极性为正离子模式的电喷雾电离技术可获得最佳的信号强度和稳定的响应。采用固相萃取直接洗脱法从血浆样品中提取药物。ATR和2-ATR的校准曲线范围为0.500-250 ng/mL, 4-ATR的校准曲线范围为0.200-20 ng/mL。发现批内和批间的精密度和准确度在整个验证过程中对所有分析物都是一致和可重复的。所有分析物和istd的提取回收率均>80%。所有分析物的峰和各自的istd在5.2 min内洗脱。在该方法中,采用了选择性的多变量分析方法,如不同强度配方的最佳拟合线性范围,代谢物体内和体外自降解的预防措施,以及更短的分析时间。这种经过验证的方法可用于具有挑战性的ATR及其活性代谢物的定量,用于治疗药物监测和高通量临床研究样本分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Assay and drug development technologies
Assay and drug development technologies 医学-生化研究方法
CiteScore
3.60
自引率
0.00%
发文量
33
审稿时长
>12 weeks
期刊介绍: ASSAY and Drug Development Technologies provides access to novel techniques and robust tools that enable critical advances in early-stage screening. This research published in the Journal leads to important therapeutics and platforms for drug discovery and development. This reputable peer-reviewed journal features original papers application-oriented technology reviews, topical issues on novel and burgeoning areas of research, and reports in methodology and technology application. ASSAY and Drug Development Technologies coverage includes: -Assay design, target development, and high-throughput technologies- Hit to Lead optimization and medicinal chemistry through preclinical candidate selection- Lab automation, sample management, bioinformatics, data mining, virtual screening, and data analysis- Approaches to assays configured for gene families, inherited, and infectious diseases- Assays and strategies for adapting model organisms to drug discovery- The use of stem cells as models of disease- Translation of phenotypic outputs to target identification- Exploration and mechanistic studies of the technical basis for assay and screening artifacts
期刊最新文献
Enhanced Anticancer Efficiency of Curcumin Co-Loaded Lawsone Solid Lipid Nanoparticles Against MCF-7 Breast Cancer Cell Lines: Optimization by Statistical JMP Software-Based Experimental Approach. Implementation of the Box-Behnken Design in the Development and Optimization of Methotrexate-Loaded Microsponges for Colon Cancer. Protective Effects of Schizochytrium Microalgal Fatty Acids on Alcoholic Liver Disease: A Network Pharmacology and In Vivo Study. In Vitro Antiviral Assays: A Review of Laboratory Methods. In Silico Screening of Phytochemicals as Potential Inhibitors of the JAK/STATs Pathway in Psoriasis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1