Hunor Kertész, Tatjana Traub-Weidinger, Jacobo Cal-Gonzalez, Ivo Rausch, Otto Muzik, Lalith Kumar Shyiam Sundar, Thomas Beyer
{"title":"Feasibility of dose reduction for [18F]FDG-PET/MR imaging of patients with non-lesional epilepsy.","authors":"Hunor Kertész, Tatjana Traub-Weidinger, Jacobo Cal-Gonzalez, Ivo Rausch, Otto Muzik, Lalith Kumar Shyiam Sundar, Thomas Beyer","doi":"10.1055/a-2015-7785","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the study was to evaluate the effect of reduced injected [18F]FDG activity levels on the quantitative and diagnostic accuracy of PET images of patients with non-lesional epilepsy (NLE).Nine healthy volunteers and nine patients with NLE underwent 60-min dynamic list-mode (LM) scans on a fully-integrated PET/MRI system. Injected FDG activity levels were reduced virtually by randomly removing counts from the last 10-min of the LM data, so as to simulate the following activity levels: 50 %, 35 %, 20 %, and 10 % of the original activity. Four image reconstructions were evaluated: standard OSEM, OSEM with resolution recovery (PSF), the A-MAP, and the Asymmetrical Bowsher (AsymBowsher) algorithms. For the A-MAP algorithms, two weights were selected (low and high). Image contrast and noise levels were evaluated for all subjects while the lesion-to-background ratio (L/B) was only evaluated for patients. Patient images were scored by a Nuclear Medicine physician on a 5-point scale to assess clinical impression associated with the various reconstruction algorithms.The image contrast and L/B ratio characterizing all four reconstruction algorithms were similar, except for reconstructions based on only 10 % of total counts. Based on clinical impression, images with diagnostic quality can be achieved with as low as 35 % of the standard injected activity. The selection of algorithms utilizing an anatomical prior did not provide a significant advantage for clinical readings, despite a small improvement in L/B (< 5 %) using the A-MAP and AsymBowsher reconstruction algorithms.In patients with NLE who are undergoing [18F]FDG-PET/MR imaging, the injected [18F]FDG activity can be reduced to 35 % of the original dose levels without compromising.</p>","PeriodicalId":19238,"journal":{"name":"Nuklearmedizin-nuclear Medicine","volume":"62 3","pages":"200-213"},"PeriodicalIF":1.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuklearmedizin-nuclear Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2015-7785","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of the study was to evaluate the effect of reduced injected [18F]FDG activity levels on the quantitative and diagnostic accuracy of PET images of patients with non-lesional epilepsy (NLE).Nine healthy volunteers and nine patients with NLE underwent 60-min dynamic list-mode (LM) scans on a fully-integrated PET/MRI system. Injected FDG activity levels were reduced virtually by randomly removing counts from the last 10-min of the LM data, so as to simulate the following activity levels: 50 %, 35 %, 20 %, and 10 % of the original activity. Four image reconstructions were evaluated: standard OSEM, OSEM with resolution recovery (PSF), the A-MAP, and the Asymmetrical Bowsher (AsymBowsher) algorithms. For the A-MAP algorithms, two weights were selected (low and high). Image contrast and noise levels were evaluated for all subjects while the lesion-to-background ratio (L/B) was only evaluated for patients. Patient images were scored by a Nuclear Medicine physician on a 5-point scale to assess clinical impression associated with the various reconstruction algorithms.The image contrast and L/B ratio characterizing all four reconstruction algorithms were similar, except for reconstructions based on only 10 % of total counts. Based on clinical impression, images with diagnostic quality can be achieved with as low as 35 % of the standard injected activity. The selection of algorithms utilizing an anatomical prior did not provide a significant advantage for clinical readings, despite a small improvement in L/B (< 5 %) using the A-MAP and AsymBowsher reconstruction algorithms.In patients with NLE who are undergoing [18F]FDG-PET/MR imaging, the injected [18F]FDG activity can be reduced to 35 % of the original dose levels without compromising.
期刊介绍:
Als Standes- und Fachorgan (Organ von Deutscher Gesellschaft für Nuklearmedizin (DGN), Österreichischer Gesellschaft für Nuklearmedizin und Molekulare Bildgebung (ÖGN), Schweizerischer Gesellschaft für Nuklearmedizin (SGNM, SSNM)) von hohem wissenschaftlichen Anspruch befasst sich die CME-zertifizierte Nuklearmedizin/ NuclearMedicine mit Diagnostik und Therapie in der Nuklearmedizin und dem Strahlenschutz: Originalien, Übersichtsarbeiten, Referate und Kongressberichte stellen aktuelle Themen der Diagnose und Therapie dar.
Ausführliche Berichte aus den DGN-Arbeitskreisen, Nachrichten aus Forschung und Industrie sowie Beschreibungen innovativer technischer Geräte, Einrichtungen und Systeme runden das Konzept ab.
Die Abstracts der Jahrestagungen dreier europäischer Fachgesellschaften sind Bestandteil der Kongressausgaben.
Nuklearmedizin erscheint regelmäßig mit sechs Ausgaben pro Jahr und richtet sich vor allem an Nuklearmediziner, Radiologen, Strahlentherapeuten, Medizinphysiker und Radiopharmazeuten.