P100 Wave Latency and Amplitude in Visual Evoked Potential Records in Different Visual Quadrants of Normal Individuals.

IF 1.6 Q3 OPHTHALMOLOGY Journal of Ophthalmic & Vision Research Pub Date : 2023-04-01 DOI:10.18502/jovr.v18i2.13184
Leila Mirzaee Saba, Hassan Hashemi, Ebrahim Jafarzadehpour, Ali Mirzajani, Abbasali Yekta, Abolfazl Jafarzadehpour, Arghavan Zarei, Payam Nabovati, Mehdi Khabazkhoob
{"title":"P100 Wave Latency and Amplitude in Visual Evoked Potential Records in Different Visual Quadrants of Normal Individuals.","authors":"Leila Mirzaee Saba,&nbsp;Hassan Hashemi,&nbsp;Ebrahim Jafarzadehpour,&nbsp;Ali Mirzajani,&nbsp;Abbasali Yekta,&nbsp;Abolfazl Jafarzadehpour,&nbsp;Arghavan Zarei,&nbsp;Payam Nabovati,&nbsp;Mehdi Khabazkhoob","doi":"10.18502/jovr.v18i2.13184","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Assessment of the pattern visual evoked potential (PVEP) responses in different areas of visual fields in individuals with normal vision.</p><p><strong>Methods: </strong>This study was conducted on 80 eyes of normal subjects aged 18-35 years. All participants underwent refraction and visual acuity examination. Visual evoked potential (VEP) responses were recorded in different areas of field. The repeated measure test was used to compare the P100 latency and amplitude of PVEP among different areas.</p><p><strong>Results: </strong>The repeated measures analysis of variance showed a statistically significant difference among different areas in terms of amplitude and latency of P100 (<i>P</i> = 0.002 and <i>P</i> <math><mo><</mo></math> 0.001, respectively). According to the results, the highest and lowest amplitude of P100 was observed in inferior-nasal and superior areas, respectively. The highest and lowest latency of P100 was related to the temporal and inferior-nasal areas, respectively.</p><p><strong>Conclusion: </strong>This study partially revealed the details of local PVEP distribution in the visual field and there was a significant difference in the amplitude and latency of PVEP wave in different areas of the visual field.</p>","PeriodicalId":16586,"journal":{"name":"Journal of Ophthalmic & Vision Research","volume":"18 2","pages":"175-181"},"PeriodicalIF":1.6000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10172794/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmic & Vision Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jovr.v18i2.13184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Assessment of the pattern visual evoked potential (PVEP) responses in different areas of visual fields in individuals with normal vision.

Methods: This study was conducted on 80 eyes of normal subjects aged 18-35 years. All participants underwent refraction and visual acuity examination. Visual evoked potential (VEP) responses were recorded in different areas of field. The repeated measure test was used to compare the P100 latency and amplitude of PVEP among different areas.

Results: The repeated measures analysis of variance showed a statistically significant difference among different areas in terms of amplitude and latency of P100 (P = 0.002 and P < 0.001, respectively). According to the results, the highest and lowest amplitude of P100 was observed in inferior-nasal and superior areas, respectively. The highest and lowest latency of P100 was related to the temporal and inferior-nasal areas, respectively.

Conclusion: This study partially revealed the details of local PVEP distribution in the visual field and there was a significant difference in the amplitude and latency of PVEP wave in different areas of the visual field.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正常人不同视觉象限视觉诱发电位记录的P100波潜伏期和振幅。
目的:评估正常视力个体不同视野区域的模式视觉诱发电位(PVEP)反应。方法:对80只18 ~ 35岁的正常人眼睛进行观察。所有参与者都进行了屈光和视力检查。在不同视场区域记录视觉诱发电位(VEP)反应。采用重复测量法比较不同区域P100潜伏期和PVEP振幅。结果:重复测量方差分析显示,不同区域间P100振幅和潜伏期差异有统计学意义(P = 0.002, P = 0.001)。结果显示,P100的最高和最低振幅分别出现在鼻下区和鼻上区。P100的最高潜伏期和最低潜伏期分别与颞区和下鼻区有关。结论:本研究部分揭示了PVEP在视野局部分布的细节,PVEP波在不同视野区域的振幅和潜伏期存在显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
63
审稿时长
30 weeks
期刊最新文献
Application of Artificial Intelligence in Ophthalmology: An Updated Comprehensive Review. Clinical Manifestations and Outcomes of Ocular Graft Versus Host Disease following Allogeneic Stem Cell Transplantation. Clinical Outcomes of Stage 2 (Pivotal) Use of a Modified Keratoprosthesis Device (ORC-KPro) in Patients with End-stage Corneal Blindness. Doxycycline versus Curcumin for Inhibition of Matrix Metalloproteinase Expression and Activity Following Chemically Induced Inflammation in Corneal Cells. Evaluation of Foveal Vasculature by Optical Coherence Tomography Angiography after Pan-Retinal Photocoagulation versus Intravitreal Anti-VEGF Injections.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1