Mechanical Dilation of the Recipient Vessel with the DeBakey Vascular Dilator in Lower Extremity Reconstruction: A Report of Two Cases.

IF 1.3 Q3 SURGERY Archives of Plastic Surgery-APS Pub Date : 2023-05-01 DOI:10.1055/s-0043-1764309
Min-Gi Seo, Tae-Gon Kim
{"title":"Mechanical Dilation of the Recipient Vessel with the DeBakey Vascular Dilator in Lower Extremity Reconstruction: A Report of Two Cases.","authors":"Min-Gi Seo,&nbsp;Tae-Gon Kim","doi":"10.1055/s-0043-1764309","DOIUrl":null,"url":null,"abstract":"<p><p>In lower extremity reconstruction, the recipient vessel often requires long-range mechanical dilation because of extensive vasospasm or plaque formation induced by concomitant atherosclerosis. While a forceps dilator can be used to manipulate and dilate vessels approximately 1 cm from their end, a DeBakey vascular dilator can dilate long-range vessels. The authors successfully performed free flap reconstruction of the lower extremity using the DeBakey vascular dilator. Of the two patients who underwent lower extremity reconstruction, one had extensive vasospasm, and the other had plaques in the recipient arteries. Irrigation with 4% lidocaine and dilation of the lumen with a forceps dilator were insufficient to restore the normal arterial blood flow. Instead, a DeBakey vascular dilator with a 1-mm diameter tip was gently inserted into the lumen. Then, to overcome vessel resistance, the dilator gently advanced approximately 10 cm to dilate the recipient artery. Normal arterial blood flow was gushed out after dilating the vessel lumen using a DeBakey vascular dilator. The vascular anastomosis was performed, and intravenous heparin 5000 IU was administered immediately after anastomosis. Prophylactic low-molecular-weight-heparin (Clexane, 1 mg/kg) was administered subcutaneously to both patients for 14 days. The reconstructed flap survived without necrosis in either patient.</p>","PeriodicalId":47543,"journal":{"name":"Archives of Plastic Surgery-APS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10226792/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Plastic Surgery-APS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1764309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

In lower extremity reconstruction, the recipient vessel often requires long-range mechanical dilation because of extensive vasospasm or plaque formation induced by concomitant atherosclerosis. While a forceps dilator can be used to manipulate and dilate vessels approximately 1 cm from their end, a DeBakey vascular dilator can dilate long-range vessels. The authors successfully performed free flap reconstruction of the lower extremity using the DeBakey vascular dilator. Of the two patients who underwent lower extremity reconstruction, one had extensive vasospasm, and the other had plaques in the recipient arteries. Irrigation with 4% lidocaine and dilation of the lumen with a forceps dilator were insufficient to restore the normal arterial blood flow. Instead, a DeBakey vascular dilator with a 1-mm diameter tip was gently inserted into the lumen. Then, to overcome vessel resistance, the dilator gently advanced approximately 10 cm to dilate the recipient artery. Normal arterial blood flow was gushed out after dilating the vessel lumen using a DeBakey vascular dilator. The vascular anastomosis was performed, and intravenous heparin 5000 IU was administered immediately after anastomosis. Prophylactic low-molecular-weight-heparin (Clexane, 1 mg/kg) was administered subcutaneously to both patients for 14 days. The reconstructed flap survived without necrosis in either patient.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DeBakey血管扩张器在下肢重建中机械扩张受体血管2例报告。
在下肢重建中,由于伴随动脉粥样硬化引起广泛的血管痉挛或斑块形成,受体血管通常需要长期的机械扩张。钳式扩张器可用于控制和扩张距离末端约1cm的血管,而DeBakey血管扩张器可扩张远端血管。作者使用DeBakey血管扩张器成功地进行了下肢自由皮瓣重建。在接受下肢重建的两名患者中,一名患者有广泛的血管痉挛,另一名患者在受体动脉中有斑块。4%利多卡因冲洗和钳式扩张器扩张管腔不足以恢复正常的动脉血流。取而代之的是,一个直径为1毫米的DeBakey血管扩张器被轻轻地插入管腔。然后,为了克服血管阻力,扩张器缓慢向前推进约10厘米以扩张受体动脉。使用DeBakey血管扩张器扩张血管腔后,正常动脉血流涌出。行血管吻合,吻合后立即静脉滴注肝素5000 IU。预防性低分子肝素(Clexane, 1 mg/kg)皮下注射14天。两例患者重建皮瓣均无坏死。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
6.70%
发文量
131
审稿时长
10 weeks
期刊最新文献
"Funducation"-The New Age of Learning, Intersection of Education, and Fun. Abdominal Wall Hernias Following High-intensity Focused Ultrasound Therapy: Three Case Reports. Neglected Superior Ophthalmic Vein Enlargement before Delayed Symptom of Carotid-Cavernous Fistula in a Blowout Fracture: A Case Report and Literature Review. Speech Outcomes after Delayed Hard Palate Closure and Synchronous Secondary Alveolar Bone Grafting in Patients with Cleft Lip, Alveolus and Palate. Fixation Techniques to Maintain Position for a Cross Leg Flap: Technical Tips and Algorithmic Approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1