Objective evaluation of the resistance forces of 22-gauge EUS-FNA and fine-needle biopsy needles.

IF 4.4 1区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY Endoscopic Ultrasound Pub Date : 2023-03-01 DOI:10.4103/EUS-D-22-00059
Yukitoshi Matsunami, Takao Itoi, Takayoshi Tsuchiya, Kentaro Ishii, Reina Tanaka, Ryosuke Tonozuka, Shuntaro Mukai, Kazumasa Nagai, Kenjiro Yamamoto, Yasutsugu Asai, Takashi Kurosawa, Hiroyuki Kojima, Hirohito Minami, Toshihiro Homma, Eri Joyama, Atsushi Sofuni
{"title":"Objective evaluation of the resistance forces of 22-gauge EUS-FNA and fine-needle biopsy needles.","authors":"Yukitoshi Matsunami,&nbsp;Takao Itoi,&nbsp;Takayoshi Tsuchiya,&nbsp;Kentaro Ishii,&nbsp;Reina Tanaka,&nbsp;Ryosuke Tonozuka,&nbsp;Shuntaro Mukai,&nbsp;Kazumasa Nagai,&nbsp;Kenjiro Yamamoto,&nbsp;Yasutsugu Asai,&nbsp;Takashi Kurosawa,&nbsp;Hiroyuki Kojima,&nbsp;Hirohito Minami,&nbsp;Toshihiro Homma,&nbsp;Eri Joyama,&nbsp;Atsushi Sofuni","doi":"10.4103/EUS-D-22-00059","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>EUS-guided tissue acquisition is routinely performed for the diagnosis of gastrointestinal tract and adjacent organ lesions. Recently, various types of needles have been developed. However, how the shape of the needle tip and echoendoscope tip angle affect puncturability, has not been clarified. The aim of this experimental study was to compare the puncturability of several 22-gauge EUS-FNA and EUS-guided fine-needle biopsy (EUS-FNB) needles, and to evaluate the effects of the needle tip shape and echoendoscope tip angle on tissue puncturability.</p><p><strong>Materials and methods: </strong>The following six major FNA and FNB needles were evaluated: SonoTip<sup>®</sup> ProControl, EZ Shot 3 Plus, Expect<sup>™</sup> Standard Handle, SonoTip<sup>®</sup> TopGain, Acquire<sup>™</sup>, and SharkCore<sup>™</sup>. The mean maximum resistance force against needle advancement was evaluated and compared under several conditions using an echoendoscope.</p><p><strong>Results: </strong>The mean maximum resistance force of the needle alone was higher for the FNB needles than for the FNA needles. The mean maximum resistance force of the needle in the echoendoscope with free angle demonstrated that the resistance forces were between 2.10 and 2.34 Newton (N). The mean maximum resistance force increased upon increases in angle of the tip of echoendoscope, particularly in the FNA needles. Among the FNB needles, SharkCore<sup>™</sup> had the lowest resistance force (2.23 N). The mean maximum resistance force of the needle alone, the needle in the echoendoscope with free angle, and the needle in the echoendoscope with full-up angle for SonoTip<sup>®</sup> TopGain were all similar to that of Acquire<sup>™</sup>.</p><p><strong>Conclusion: </strong>SonoTip<sup>®</sup> TopGain had similar puncturability to Acquire<sup>™</sup> in all tested situations. Regarding the puncturability, SharkCore<sup>™</sup> is most suitable for insertion into target lesions, when tight echoendoscope tip angle is necessary.</p>","PeriodicalId":11577,"journal":{"name":"Endoscopic Ultrasound","volume":"12 2","pages":"251-258"},"PeriodicalIF":4.4000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9a/83/EUS-12-251.PMC10237597.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopic Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/EUS-D-22-00059","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 3

Abstract

Background and objectives: EUS-guided tissue acquisition is routinely performed for the diagnosis of gastrointestinal tract and adjacent organ lesions. Recently, various types of needles have been developed. However, how the shape of the needle tip and echoendoscope tip angle affect puncturability, has not been clarified. The aim of this experimental study was to compare the puncturability of several 22-gauge EUS-FNA and EUS-guided fine-needle biopsy (EUS-FNB) needles, and to evaluate the effects of the needle tip shape and echoendoscope tip angle on tissue puncturability.

Materials and methods: The following six major FNA and FNB needles were evaluated: SonoTip® ProControl, EZ Shot 3 Plus, Expect Standard Handle, SonoTip® TopGain, Acquire, and SharkCore. The mean maximum resistance force against needle advancement was evaluated and compared under several conditions using an echoendoscope.

Results: The mean maximum resistance force of the needle alone was higher for the FNB needles than for the FNA needles. The mean maximum resistance force of the needle in the echoendoscope with free angle demonstrated that the resistance forces were between 2.10 and 2.34 Newton (N). The mean maximum resistance force increased upon increases in angle of the tip of echoendoscope, particularly in the FNA needles. Among the FNB needles, SharkCore had the lowest resistance force (2.23 N). The mean maximum resistance force of the needle alone, the needle in the echoendoscope with free angle, and the needle in the echoendoscope with full-up angle for SonoTip® TopGain were all similar to that of Acquire.

Conclusion: SonoTip® TopGain had similar puncturability to Acquire in all tested situations. Regarding the puncturability, SharkCore is most suitable for insertion into target lesions, when tight echoendoscope tip angle is necessary.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
目的评价22号EUS-FNA和细针活检针的阻力。
背景和目的:EUS引导的组织采集是诊断胃肠道和邻近器官病变的常规方法。最近,已经开发出了各种类型的针头。然而,针尖的形状和回声内窥镜针尖的角度如何影响穿刺性,目前尚不清楚。本实验研究的目的是比较几种22号EUS-FNA和EUS引导的细针活检(EUS-FNB)针的穿刺能力,并评估针尖形状和回声内窥镜针尖角度对组织穿刺能力的影响。材料和方法:评估了以下六种主要的FNA和FNB针:SonoTip®ProControl、EZ-Shot 3 Plus、Expect™ 标准手柄,SonoTip®TopGain,采集™, 和SharkCore™. 使用回声内窥镜在几种条件下评估和比较针前进的平均最大阻力。结果:FNB针的平均最大阻力高于FNA针。具有自由角的回声内窥镜中针头的平均最大阻力表明阻力在2.10和2.34牛顿(N)之间。平均最大阻力随着回声内窥镜尖端角度的增加而增加,尤其是在FNA针中。在FNB针中,SharkCore™ 具有最低的阻力(2.23N)。SonoTip®TopGain的单独针头、具有自由角度的回声内窥镜中的针头和具有全上角度的回声内视镜中的针头的平均最大阻力均与Acquire相似™.结论:SonoTip®TopGain与Acquire具有相似的穿刺性™ 在所有测试情况下。关于可穿透性,SharkCore™ 最适合插入目标病变,当需要紧密的回声内窥镜尖端角度时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Endoscopic Ultrasound
Endoscopic Ultrasound GASTROENTEROLOGY & HEPATOLOGY-
CiteScore
6.20
自引率
11.10%
发文量
144
期刊介绍: Endoscopic Ultrasound, a publication of Euro-EUS Scientific Committee, Asia-Pacific EUS Task Force and Latin American Chapter of EUS, is a peer-reviewed online journal with Quarterly print on demand compilation of issues published. The journal’s full text is available online at http://www.eusjournal.com. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository. The journal does not charge for submission, processing or publication of manuscripts and even for color reproduction of photographs.
期刊最新文献
Consensus guidelines on the diagnosis and treatment of pancreatic pseudocyst and walled-off necrosis from a Chinese multiple disciplinary team expert panel Computed tomography–based radial endobronchial ultrasound image simulation of peripheral pulmonary lesions using deep learning Comments and illustrations of the European Federation of Societies for Ultrasound in Medicine contrast-enhanced ultrasound guidelines: Multiparametric imaging and EUS-guided sampling in rare pancreatic tumors. Benign mesenchymal pancreatic tumors A rare but interesting case of small intestinal tumor diagnosed by transrectal EUS-FNA (with video). Detective flow imaging versus contrast-enhanced EUS in solid pancreatic lesions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1