Automatic screening of patients with atrial fibrillation from 24-h Holter recording using deep learning.

IF 3.9 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS European heart journal. Digital health Pub Date : 2023-05-01 DOI:10.1093/ehjdh/ztad018
Peng Zhang, Fan Lin, Fei Ma, Yuting Chen, Siyi Fang, Haiyan Zheng, Zuwen Xiang, Xiaoyun Yang, Qiang Li
{"title":"Automatic screening of patients with atrial fibrillation from 24-h Holter recording using deep learning.","authors":"Peng Zhang,&nbsp;Fan Lin,&nbsp;Fei Ma,&nbsp;Yuting Chen,&nbsp;Siyi Fang,&nbsp;Haiyan Zheng,&nbsp;Zuwen Xiang,&nbsp;Xiaoyun Yang,&nbsp;Qiang Li","doi":"10.1093/ehjdh/ztad018","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>As the demand for atrial fibrillation (AF) screening increases, clinicians spend a significant amount of time identifying AF signals from massive amounts of data obtained during long-term dynamic electrocardiogram (ECG) monitoring. The identification of AF signals is subjective and depends on the experience of clinicians. However, experienced cardiologists are scarce. This study aimed to apply a deep learning-based algorithm to fully automate primary screening of patients with AF using 24-h Holter monitoring.</p><p><strong>Methods and results: </strong>A deep learning model was developed to automatically detect AF episodes using RR intervals and was trained and evaluated on 23 621 (2297 AF and 21 324 non-AF) 24-h Holter recordings from 23 452 patients. Based on the AF episode detection results, patients with AF were automatically identified using the criterion of at least one AF episode lasting 6 min or longer. Performance was assessed on an independent real-world hospital-scenario test set (19 227 recordings) and a community-scenario test set (1299 recordings). For the two test sets, the model obtained high performance for the identification of patients with AF (sensitivity: 0.995 and 1.000; specificity: 0.985 and 0.997, respectively). Moreover, it obtained good and consistent performance (sensitivity: 1.000; specificity: 0.972) for an external public data set.</p><p><strong>Conclusion: </strong>Using the criterion of at least one AF episode of 6 min or longer, the deep learning model can fully automatically screen patients for AF with high accuracy from long-term Holter monitoring data. This method may serve as a powerful and cost-effective tool for primary screening for AF.</p>","PeriodicalId":72965,"journal":{"name":"European heart journal. Digital health","volume":null,"pages":null},"PeriodicalIF":3.9000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/42/c9/ztad018.PMC10232289.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal. Digital health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjdh/ztad018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

Abstract

Aims: As the demand for atrial fibrillation (AF) screening increases, clinicians spend a significant amount of time identifying AF signals from massive amounts of data obtained during long-term dynamic electrocardiogram (ECG) monitoring. The identification of AF signals is subjective and depends on the experience of clinicians. However, experienced cardiologists are scarce. This study aimed to apply a deep learning-based algorithm to fully automate primary screening of patients with AF using 24-h Holter monitoring.

Methods and results: A deep learning model was developed to automatically detect AF episodes using RR intervals and was trained and evaluated on 23 621 (2297 AF and 21 324 non-AF) 24-h Holter recordings from 23 452 patients. Based on the AF episode detection results, patients with AF were automatically identified using the criterion of at least one AF episode lasting 6 min or longer. Performance was assessed on an independent real-world hospital-scenario test set (19 227 recordings) and a community-scenario test set (1299 recordings). For the two test sets, the model obtained high performance for the identification of patients with AF (sensitivity: 0.995 and 1.000; specificity: 0.985 and 0.997, respectively). Moreover, it obtained good and consistent performance (sensitivity: 1.000; specificity: 0.972) for an external public data set.

Conclusion: Using the criterion of at least one AF episode of 6 min or longer, the deep learning model can fully automatically screen patients for AF with high accuracy from long-term Holter monitoring data. This method may serve as a powerful and cost-effective tool for primary screening for AF.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用深度学习从24小时动态心电图记录中自动筛选房颤患者。
目的:随着对房颤(AF)筛查需求的增加,临床医生花费大量时间从长期动态心电图(ECG)监测中获得的大量数据中识别房颤信号。AF信号的识别是主观的,取决于临床医生的经验。然而,经验丰富的心脏病专家是稀缺的。本研究旨在应用基于深度学习的算法,通过24小时动态心电图监测对房颤患者进行全自动初步筛查。方法和结果:开发了一个深度学习模型,根据RR间隔自动检测AF发作,并对来自23 452例患者的23 621(2297例AF和21 324例非AF) 24小时动态心电图进行了训练和评估。根据AF发作检测结果,使用至少一次AF发作持续6分钟或更长时间的标准自动识别AF患者。通过独立的真实世界医院场景测试集(19227个录音)和社区场景测试集(1299个录音)对性能进行评估。对于两个测试集,该模型对AF患者的识别具有较高的性能(灵敏度分别为0.995和1.000;特异性:分别为0.985和0.997)。并且获得了良好且一致的性能(灵敏度:1.000;特异性:0.972)。结论:深度学习模型以至少一次房颤发作6 min及以上为标准,可从长期动态心电图监测数据中全自动、高精度地筛选房颤患者。这种方法可以作为一种强大的和具有成本效益的工具,用于房颤的初步筛查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.00
自引率
0.00%
发文量
0
期刊最新文献
Correction to: The association of electronic health literacy with behavioural and psychological coronary artery disease risk factors in patients after percutaneous coronary intervention: a 12-month follow-up study. Prospects for artificial intelligence-enhanced electrocardiogram as a unified screening tool for cardiac and non-cardiac conditions: an explorative study in emergency care. Unlocking the potential of artificial intelligence in electrocardiogram biometrics: age-related changes, anomaly detection, and data authenticity in mobile health platforms. Hypertrophic cardiomyopathy detection with artificial intelligence electrocardiography in international cohorts: an external validation study. Development and validation of risk prediction model for recurrent cardiovascular events among Chinese: the Personalized CARdiovascular DIsease risk Assessment for Chinese model.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1