{"title":"Feasibility of Simple Evaluation of Coronary Artery Calcium Using a Number of Chest Computed Tomography Slices: A Multicenter Study.","authors":"Hideya Yamamoto, Shinichiro Fujimoto, Chihiro Aoshima, Tohru Minamino, Takashi Fujii, Shinichi Wakabayashi, Yoji Urabe, Hironori Ueda, Eiji Kunita, Mitsunori Abe, Hiroshi Higashino","doi":"10.3400/avd.oa.22-00060","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> We aimed to evaluate the visual measurements of coronary artery calcium (CAC) on nonelectrocardiogram (ECG)-gated chest computed tomography (CT) using a simple scoring method that involves counting the number of CT slices containing CAC. <b>Materials and Methods:</b> We analyzed 163 participants who underwent both coronary and chest CT examinations at six centers within 3 months. Agatston scores were calculated on standard ECG-gated scans and classified as none (0), mild (1-99), moderate (100-400), or severe (>400). Next, chest CT images were reconstructed to standard 5.0 mm axial slices. Then, CAC on chest CT scans was measured using two methods: the Weston score (sum of the assigned score of each vessel, range: 0-12) and number of slices showing CAC (Ca-slice#). <b>Results:</b> When the Weston score and Ca-slice# were divided into four levels according to the optimal divisional levels corresponding to the Agatston score classes, good agreements with the 4-grade Agatston score were observed (kappa value=0.610 and 0.794, respectively). The sensitivity and specificity of Ca-slice# ≥9 to identify severe Agatston scores of >400 were 86% and 96%, respectively. <b>Conclusion:</b> The Ca-slice#, a simple scoring method using chest CT scans, was in good agreement with the ECG-gated Agatston score.</p>","PeriodicalId":7995,"journal":{"name":"Annals of vascular diseases","volume":"16 1","pages":"46-53"},"PeriodicalIF":0.6000,"publicationDate":"2023-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/69/1c/avd-16-1-oa.22-00060.PMC10064303.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of vascular diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3400/avd.oa.22-00060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: We aimed to evaluate the visual measurements of coronary artery calcium (CAC) on nonelectrocardiogram (ECG)-gated chest computed tomography (CT) using a simple scoring method that involves counting the number of CT slices containing CAC. Materials and Methods: We analyzed 163 participants who underwent both coronary and chest CT examinations at six centers within 3 months. Agatston scores were calculated on standard ECG-gated scans and classified as none (0), mild (1-99), moderate (100-400), or severe (>400). Next, chest CT images were reconstructed to standard 5.0 mm axial slices. Then, CAC on chest CT scans was measured using two methods: the Weston score (sum of the assigned score of each vessel, range: 0-12) and number of slices showing CAC (Ca-slice#). Results: When the Weston score and Ca-slice# were divided into four levels according to the optimal divisional levels corresponding to the Agatston score classes, good agreements with the 4-grade Agatston score were observed (kappa value=0.610 and 0.794, respectively). The sensitivity and specificity of Ca-slice# ≥9 to identify severe Agatston scores of >400 were 86% and 96%, respectively. Conclusion: The Ca-slice#, a simple scoring method using chest CT scans, was in good agreement with the ECG-gated Agatston score.