Max Hamaker, Casey M Codd, Catherine C May, Nathan N O'Hara, Joshua M Abzug
{"title":"Canal Fill of the Forearm Bones When Placing Intramedullary Nails in the Pediatric and Adolescent Populations.","authors":"Max Hamaker, Casey M Codd, Catherine C May, Nathan N O'Hara, Joshua M Abzug","doi":"10.1177/15589447231175514","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In the lower extremity, studies have suggested an optimal nail diameter to medullary canal diameter (ND/MCD) ratio to minimize postoperative complications. The goal of this study was to determine whether a correlation exists between the occurrence of complications, angulation, and range of motion and the ratio of the ND/MCD in the upper extremity.</p><p><strong>Methods: </strong>A total of 85 radius and ulna fractures treated with flexible intramedullary nails had ND/MCD ratios measured. Random-effects models were developed to determine the association between complications and ND/MCD ratio, angulation and ND/MCD ratio, and range of motion and ND/MCD ratio. The results were reported for unadjusted models and adjusted models.</p><p><strong>Results: </strong>Of the 85 forearm fractures treated with intramedullary nailing, there were 3 complications. The average follow-up was 6 months. The ND/MCD ratios were categorized as <0.50, 0.50 to 0.59, and ≥0.60. There was not a significant association between the different ratios and angulation, or risk of complication. There was an association between the ND/MCD ratio ≥0.60 and decreased pronation of -1.58° (-2.77° to -0.38°) and supination of -2.68° (-4.91° to -0.46°) (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>This study found that there was not an association between the nail to canal diameter ratio and postoperative angulation in forearm fractures treated with flexible intramedullary nails. When choosing a flexible nail for forearm fractures, there does not appear to be an optimal ratio; it is therefore reasonable to use the ND that passes more easily.</p>","PeriodicalId":12902,"journal":{"name":"HAND","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11536834/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HAND","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15589447231175514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: In the lower extremity, studies have suggested an optimal nail diameter to medullary canal diameter (ND/MCD) ratio to minimize postoperative complications. The goal of this study was to determine whether a correlation exists between the occurrence of complications, angulation, and range of motion and the ratio of the ND/MCD in the upper extremity.
Methods: A total of 85 radius and ulna fractures treated with flexible intramedullary nails had ND/MCD ratios measured. Random-effects models were developed to determine the association between complications and ND/MCD ratio, angulation and ND/MCD ratio, and range of motion and ND/MCD ratio. The results were reported for unadjusted models and adjusted models.
Results: Of the 85 forearm fractures treated with intramedullary nailing, there were 3 complications. The average follow-up was 6 months. The ND/MCD ratios were categorized as <0.50, 0.50 to 0.59, and ≥0.60. There was not a significant association between the different ratios and angulation, or risk of complication. There was an association between the ND/MCD ratio ≥0.60 and decreased pronation of -1.58° (-2.77° to -0.38°) and supination of -2.68° (-4.91° to -0.46°) (P < .05).
Conclusion: This study found that there was not an association between the nail to canal diameter ratio and postoperative angulation in forearm fractures treated with flexible intramedullary nails. When choosing a flexible nail for forearm fractures, there does not appear to be an optimal ratio; it is therefore reasonable to use the ND that passes more easily.
期刊介绍:
HAND is the official journal of the American Association for Hand Surgery and is a peer-reviewed journal featuring articles written by clinicians worldwide presenting current research and clinical work in the field of hand surgery. It features articles related to all aspects of hand and upper extremity surgery and the post operative care and rehabilitation of the hand.