Investigating Glenohumeral Joint Contact Forces and Kinematics in Different Keyboard and Monitor Setups using Opensim.

Milad Gholami, Alireza Choobineh, Mohammad Taghi Karimi, Azizallah Dehghan, Mohammad Abdoli-Eramaki
{"title":"Investigating Glenohumeral Joint Contact Forces and Kinematics in Different Keyboard and Monitor Setups using Opensim.","authors":"Milad Gholami,&nbsp;Alireza Choobineh,&nbsp;Mohammad Taghi Karimi,&nbsp;Azizallah Dehghan,&nbsp;Mohammad Abdoli-Eramaki","doi":"10.31661/jbpe.v0i0.2210-1450","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The musculoskeletal complaints of the shoulder are prevalent in people who work with computers for a long time.</p><p><strong>Objective: </strong>This study aimed to investigate the glenohumeral joint contact forces and kinematics in different keyboards and monitor setups using OpenSim.</p><p><strong>Material and methods: </strong>Twelve randomly selected healthy males participated in an experimental study. A 3×3 factorial design was used in which three angles were considered for the monitor and three horizontal distances for the keyboard while performing standard tasks. The workstation was adjusted based on ANSI/HFES-100-2007 standard to maintain a comfortable ergonomic posture for controlling confounding variables. Qualisys motion capture system and OpenSim were used.</p><p><strong>Results: </strong>The maximum mean range of motion (ROM) of both shoulders' flexion and adduction was observed when the keyboard was 15 cm from the edge of the desk, and the monitor angle was 30°. The maximum mean ROM of both shoulders' internal rotation was recorded for the keyboard at the edge of the desk. Peak forces for most right shoulder complex muscles were obtained in two setups. 3D shoulder joint moments were significantly different among nine setups (<i>P</i>-value<0.05). The peak anteroposterior and mediolateral joint contact forces were recorded for the keyboard at 15 cm and the monitor at zero angles (0.751 and 0.780 N/BW, respectively). The peak vertical joint contact force was observed for the keyboard at 15 cm and the monitor at 15° (0.310 N/BW).</p><p><strong>Conclusion: </strong>The glenohumeral joint contact forces are minimum for the keyboard at 8 cm and the monitor at zero angles.</p>","PeriodicalId":38035,"journal":{"name":"Journal of Biomedical Physics and Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/65/0c/JBPE-13-281.PMC10258209.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/jbpe.v0i0.2210-1450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The musculoskeletal complaints of the shoulder are prevalent in people who work with computers for a long time.

Objective: This study aimed to investigate the glenohumeral joint contact forces and kinematics in different keyboards and monitor setups using OpenSim.

Material and methods: Twelve randomly selected healthy males participated in an experimental study. A 3×3 factorial design was used in which three angles were considered for the monitor and three horizontal distances for the keyboard while performing standard tasks. The workstation was adjusted based on ANSI/HFES-100-2007 standard to maintain a comfortable ergonomic posture for controlling confounding variables. Qualisys motion capture system and OpenSim were used.

Results: The maximum mean range of motion (ROM) of both shoulders' flexion and adduction was observed when the keyboard was 15 cm from the edge of the desk, and the monitor angle was 30°. The maximum mean ROM of both shoulders' internal rotation was recorded for the keyboard at the edge of the desk. Peak forces for most right shoulder complex muscles were obtained in two setups. 3D shoulder joint moments were significantly different among nine setups (P-value<0.05). The peak anteroposterior and mediolateral joint contact forces were recorded for the keyboard at 15 cm and the monitor at zero angles (0.751 and 0.780 N/BW, respectively). The peak vertical joint contact force was observed for the keyboard at 15 cm and the monitor at 15° (0.310 N/BW).

Conclusion: The glenohumeral joint contact forces are minimum for the keyboard at 8 cm and the monitor at zero angles.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用Opensim研究不同键盘和显示器设置下关节接触力和运动学。
背景:肩部肌肉骨骼疾病在长期使用电脑的人群中很普遍。目的:本研究旨在利用OpenSim软件研究不同键盘和显示器设置下的关节接触力和运动学。材料与方法:随机选取12名健康男性参加实验研究。在执行标准任务时,使用了3×3因子设计,其中考虑了显示器的三个角度和键盘的三个水平距离。根据ANSI/ hpes -100-2007标准对工作站进行调整,以保持舒适的人体工程学姿势,控制混杂变量。使用Qualisys运动捕捉系统和OpenSim。结果:键盘距桌面边缘15 cm,显示器角度为30°时,双肩屈伸和内收的最大平均活动范围(ROM)。在桌子边缘的键盘上记录了两肩内部旋转的最大平均ROM。在两个设置中获得了大多数右肩复杂肌肉的峰值力。结论:键盘为8 cm时肩关节接触力最小,显示器为0角度时肩关节接触力最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Biomedical Physics and Engineering
Journal of Biomedical Physics and Engineering Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.90
自引率
0.00%
发文量
64
审稿时长
10 weeks
期刊介绍: The Journal of Biomedical Physics and Engineering (JBPE) is a bimonthly peer-reviewed English-language journal that publishes high-quality basic sciences and clinical research (experimental or theoretical) broadly concerned with the relationship of physics to medicine and engineering.
期刊最新文献
A Neural Network-based Approach to Prediction of Preterm Birth using Non-invasive Tests. Altered Amplitude of Low-Frequency Fluctuations of rs-fMRI Signal followed by rTMS Analgesic Effects in Non-Specific Chronic Low Back Pain (CLBP) Patients. Comparative Evaluation of LED Light Application and Heat Generation with Three Different Wavelengths of Frequency on Soft Tissues in Bringing Faster Orthodontic Tooth Movement: A Finite Element Model Study. Feasibility of Robot-Assistance Hand Physiotherapy in Post-Stroke Patients. Impact of Electronic Collimation on Reducing Unnecessary Patient Dose in Digital Radiography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1