Andrea Sbrozzzi-Vanni, Giuseppe Galloro, Matteo Piciucchi, Danilo Castellani, Ugo Germani, Iginio Dell'Amico, Francesco Zito, Socrate Pallio, Santi Mangiafico, Angelo Zullo, Raffaele Manta
{"title":"Over-the-scope Technique for Partially Covered Self-expandable Metal Stent Placement to Treat Duodenal Perforation during EUS.","authors":"Andrea Sbrozzzi-Vanni, Giuseppe Galloro, Matteo Piciucchi, Danilo Castellani, Ugo Germani, Iginio Dell'Amico, Francesco Zito, Socrate Pallio, Santi Mangiafico, Angelo Zullo, Raffaele Manta","doi":"10.15403/jgld-4625","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Although endoscopic ultrasound (EUS) is generally safe, duodenal perforation may occur during the procedure. When the iatrogenic break is wide, endoscopic positioning of a covered self- expandable metal stent is indicated to avoid a more invasive surgical approach. We evaluated the efficacy of the 'over-the-scope stenting' (OTSS) technique to treat iatrogenic duodenal perforations occurred during EUS.</p><p><strong>Methods: </strong>Data of patients with large iatrogenic duodenal perforations treated with OTSS procedure were collected in 5 centers. Technical success was defined as a correct stent placement on the perforation site, and clinical success as complete healing of the duodenal leak at stent removal 3 weeks later.</p><p><strong>Results: </strong>A total of 15 (7 males; median age: 78 years, range 47-91) patients were included in this series. A correct stent positioning was achieved in all cases (technical success: 100%), and the perforation was healed in all, apart from one patient at stent removal (clinical success: 93%). This patient was successfully treated with a novel stent placement. No immediate post-procedural adverse events occurred, and no need for emergency surgery was recorded. In one (6.7%) patient, stent migration occurred 10 days after positioning, and it was spontaneously expulsed with stool movement without complications two days later.</p><p><strong>Conclusions: </strong>Our data showed that the OTTS technique for partially covered self-expandable metal stent placement is feasible, safe and effective to tread large iatrogenic duodenal perforation occuring during EUS.</p>","PeriodicalId":50189,"journal":{"name":"Journal of Gastrointestinal and Liver Diseases","volume":"32 1","pages":"65-69"},"PeriodicalIF":2.1000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Gastrointestinal and Liver Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.15403/jgld-4625","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and aims: Although endoscopic ultrasound (EUS) is generally safe, duodenal perforation may occur during the procedure. When the iatrogenic break is wide, endoscopic positioning of a covered self- expandable metal stent is indicated to avoid a more invasive surgical approach. We evaluated the efficacy of the 'over-the-scope stenting' (OTSS) technique to treat iatrogenic duodenal perforations occurred during EUS.
Methods: Data of patients with large iatrogenic duodenal perforations treated with OTSS procedure were collected in 5 centers. Technical success was defined as a correct stent placement on the perforation site, and clinical success as complete healing of the duodenal leak at stent removal 3 weeks later.
Results: A total of 15 (7 males; median age: 78 years, range 47-91) patients were included in this series. A correct stent positioning was achieved in all cases (technical success: 100%), and the perforation was healed in all, apart from one patient at stent removal (clinical success: 93%). This patient was successfully treated with a novel stent placement. No immediate post-procedural adverse events occurred, and no need for emergency surgery was recorded. In one (6.7%) patient, stent migration occurred 10 days after positioning, and it was spontaneously expulsed with stool movement without complications two days later.
Conclusions: Our data showed that the OTTS technique for partially covered self-expandable metal stent placement is feasible, safe and effective to tread large iatrogenic duodenal perforation occuring during EUS.
期刊介绍:
The Journal of Gastrointestinal and Liver Diseases (formerly Romanian Journal of Gastroenterology) publishes papers reporting original clinical and scientific research, which are of a high standard and which contribute to the advancement of knowledge in the field of gastroenterology and hepatology. The field comprises prevention, diagnosis and management of gastrointestinal and hepatobiliary disorders, as well as related molecular genetics, pathophysiology, and epidemiology. The journal also publishes reviews, editorials and short communications on those specific topics. Case reports will be accepted if of great interest and well investigated.