{"title":"Deflection of tandem archwire in a specific self-ligating metal bracket system: an in vitro study.","authors":"Lourenço Cattani,&nbsp;Lourenço Correr-Sobrinho,&nbsp;José Guilherme Neves,&nbsp;Heloísa Valdrighi,&nbsp;Eduardo César Almada Santos,&nbsp;Ana Rosa Costa","doi":"10.1590/1807-3107bor-2023.vol37.0065","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014\" + .014\" round archwires; G2 - two .014\" + .016\" round archwires; G3 - .014\" x .025\" rectangular archwire; and. G4 - .016\" x .022\" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.</p>","PeriodicalId":48942,"journal":{"name":"Brazilian Oral Research","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Oral Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1807-3107bor-2023.vol37.0065","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
串联弓丝在特定自结扎金属支架系统中的偏转:一项体外研究。
本研究的目的是量化在被动自结扎支架的特定系统中串联弓线所施加的力。48根热激活镍钛正畸弓丝分为4组(n = 12): G1 - 2根0.014“+ 0.014”圆弓丝;G2 -两根0.014“+ 0.016”圆形拱线;G3 - 0.014 " x 0.025 "矩形拱线;和。G4 - 0.016 " x 0.022 "矩形拱线。使用代表上牙的装置将托槽固定在1.5 ~ 2.5牙上,保持托槽间距离6.0 mm。以1.1齿代表结构为支撑,在Instron试验机上以2.0 mm/min的速度进行挠度试验。在0.5 mm、1.0 mm和1.5 mm的挠度下评估弓丝。采用广义线性模型对数据进行分析,将不同偏转值视为同一实验单元的重复测量值(α = 0.5%)。在0.5 mm处,G2和G3的受力较大,差异无统计学意义(p > 0.05)。G4组力最小(p < 0.05)。在1.0 mm和1.5 mm时,G3的力最大,其次是G4和G2 (p < 0.05)。G1组力最小(p < 0.05)。一般情况下,在特定被动自结扎支架中的串联弓丝(相同或不同口径)与矩形弓丝相比施加的力更小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Brazilian Oral Research
Brazilian Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.70
自引率
4.00%
发文量
107
审稿时长
12 weeks
期刊最新文献
Erratum: Virtual learning object about oral ulcerative lesions: controlled educational intervention study. Braz. Oral Res. 2023:37:e118. Comparative study of sex estimates in adult skulls using direct measurement and tomographic image reconstruction. Braz Oral Res. 2023;37:e064. Association among COVID-19, multisystem inflammatory syndrome in children, and oral health status. Braz Oral Res. 2023;37:e072. Evaluation of peripheral nerve fibers and mast cells in burning mouth syndrome. Erratum: Evaluation of the expression of nerve fiber markers in healthy and inflamed dental pulp. Braz Oral Res. 2023;37:e020.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1