{"title":"Proximal radiolucent lines around fully hydroxyapatite-coated tapered femoral stems: should we be concerned?","authors":"Zachary P Berliner, Muhammad Umar Jawad, Chelsea Matzko, H John Cooper, Jose A Rodriguez, Matthew S Hepinstall","doi":"10.1177/11207000231178269","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome.</p><p><strong>Methods: </strong>All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (<i>n =</i> 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients.</p><p><strong>Results: </strong>Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal ⅓ of the stem correlated with the development of radiolucent lines (<i>p <</i> 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines.</p><p><strong>Discussion: </strong>We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000231178269","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome.

Methods: All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (n = 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients.

Results: Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal ⅓ of the stem correlated with the development of radiolucent lines (p < 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines.

Discussion: We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全羟基磷灰石涂层锥形股骨柄周围的近端放射线:我们应该关注吗?
简介:全髋关节置换术(THA)后,全羟基磷灰石(HA)涂层锥形股骨柄近端偶尔会出现放射线。假设柄的远端楔入可能会导致近端放射状线的形成,从而对临床效果产生负面影响:方法:在手术数据库(n = 244)中确定了所有使用无领全HA涂层骨干进行的初级THA,并进行了至少1年的放射学随访。分析了股骨近端形态和股骨柄中远端三分之二处股骨管充盈度的X光测量值与近端放射线是否存在相关性。线性回归用于探究桡骨透明线与患者报告结果指标(PROMs)之间的关联,61%的患者可获得患者报告结果指标:最后随访时,31 例患者(12.7%)出现了近端桡骨放射线。Dorr A股骨形态和股骨柄远端⅓处的管腔填充增加与放射线的发展有关(P 0.001)。疼痛或PROM与近端桡骨放射线之间没有相关性:我们观察到,无领全HA涂层柄的股骨近端放射状线发生率出乎意料地高。Dorr A骨中仅远端种植体楔入可能会影响近端固定。虽然这一发现与短期疗效无关,但其长期临床影响仍需进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
HIP International
HIP International 医学-整形外科
CiteScore
4.20
自引率
0.00%
发文量
70
审稿时长
2 months
期刊介绍: HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice. The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit. HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are: • Biomaterials • Biomechanics • Conservative Hip Surgery • Paediatrics • Primary and Revision Hip Arthroplasty • Traumatology
期刊最新文献
The push-through total femoral prosthesis for revision of a total hip or knee replacement with extreme bone loss. Assessment of radiological and functional outcomes of complex acetabulum fracture managed with combined anterior and posterior approach in a single anaesthetic setting: a retrospective study. The L1 spino-pelvic (L1SP) angle: a simplified approach for the assessment of the PI-LL mismatch in hip surgery. The management of anticoagulated fragility femoral fracture patients. Patient-reported outcomes in total hip arthroplasty for patients with anatomically contoured femoral heads.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1