Cemented and cementless dual mobility cups show similar fixation, low polyethylene wear, and low serum cobalt-chromium in elderly patients: a randomized radiostereometry study with 6 years' follow-up.

IF 2.5 2区 医学 Q1 ORTHOPEDICS Acta Orthopaedica Pub Date : 2022-12-16 DOI:10.2340/17453674.2022.5761
Peter Bo Jørgensen, Steffan Tabori-Jensen, Inger Mechlenburg, Morten Homilius, Torben Bæk Hansen, Maiken Stilling
{"title":"Cemented and cementless dual mobility cups show similar fixation, low polyethylene wear, and low serum cobalt-chromium in elderly patients: a randomized radiostereometry study with 6 years' follow-up.","authors":"Peter Bo Jørgensen, Steffan Tabori-Jensen, Inger Mechlenburg, Morten Homilius, Torben Bæk Hansen, Maiken Stilling","doi":"10.2340/17453674.2022.5761","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Dual mobility (DM) articulation total hip arthroplasty (THA) is used increasingly to reduce dislocation risk. We investigated cup fixation, polyethylene (PE) wear, serum chromium and cobalt ions, and their correlation to physical activity in patients with DM cups at 6-year follow-up.</p><p><strong>Patients and methods: </strong>In a patient-blinded RCT, 60 patients with hip osteoarthritis at a median age of 74 years (70-82) were randomly allocated to cemented (n = 30) or cementless hydroxyapatite-coated (n = 30) fixation of Avantage DM THA with a highly-crosslinked vitamin-E PE liner. Cup migration and PE wear were measured with radiostereometric analysis (RSA), chromium and cobalt ions were measured in serum, and physical activity was measured with accelerometers.</p><p><strong>Results: </strong>At 6-year follow-up, proximal cup migration was similar: 0.14 mm (95% CI 0.01-0.28) for cemented cups and 0.21 mm (0.02-0.39) for cementless cups. The PE wear rate from 1- to 6-year follow-up was also similar: 0.06 mm/year (0.04-0.09) for cemented cups and 0.07 mm/year (0.04-0.11) for cementless cups. Serum metal ion levels were undetectable or very low. Physical activity was mainly low intensity and did not correlate to PE wear rate or cup migration.</p><p><strong>Conclusion: </strong>Cemented and cementless DM cups with highly crosslinked vitamin-E infused liners have similar cup migration and PE wear when used for primary THA surgery.</p>","PeriodicalId":6916,"journal":{"name":"Acta Orthopaedica","volume":"93 ","pages":"906-913"},"PeriodicalIF":2.5000,"publicationDate":"2022-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/8b/4d/ActaO-93-5761.PMC9772923.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Orthopaedica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/17453674.2022.5761","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: Dual mobility (DM) articulation total hip arthroplasty (THA) is used increasingly to reduce dislocation risk. We investigated cup fixation, polyethylene (PE) wear, serum chromium and cobalt ions, and their correlation to physical activity in patients with DM cups at 6-year follow-up.

Patients and methods: In a patient-blinded RCT, 60 patients with hip osteoarthritis at a median age of 74 years (70-82) were randomly allocated to cemented (n = 30) or cementless hydroxyapatite-coated (n = 30) fixation of Avantage DM THA with a highly-crosslinked vitamin-E PE liner. Cup migration and PE wear were measured with radiostereometric analysis (RSA), chromium and cobalt ions were measured in serum, and physical activity was measured with accelerometers.

Results: At 6-year follow-up, proximal cup migration was similar: 0.14 mm (95% CI 0.01-0.28) for cemented cups and 0.21 mm (0.02-0.39) for cementless cups. The PE wear rate from 1- to 6-year follow-up was also similar: 0.06 mm/year (0.04-0.09) for cemented cups and 0.07 mm/year (0.04-0.11) for cementless cups. Serum metal ion levels were undetectable or very low. Physical activity was mainly low intensity and did not correlate to PE wear rate or cup migration.

Conclusion: Cemented and cementless DM cups with highly crosslinked vitamin-E infused liners have similar cup migration and PE wear when used for primary THA surgery.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
骨水泥和无骨水泥双活动度杯在老年患者中显示出相似的固定性、较低的聚乙烯磨损和较低的血清钴铬:一项为期 6 年的随机放射线测量研究。
背景和目的:双活动度(DM)关节全髋关节置换术(THA)越来越多地用于降低脱位风险。我们研究了DM杯患者6年随访期间的髋臼杯固定、聚乙烯(PE)磨损、血清铬和钴离子及其与体力活动的相关性:在一项患者盲法 RCT 研究中,60 名中位年龄为 74 岁(70-82 岁)的髋关节骨性关节炎患者被随机分配到有高交联维生素-E 聚乙烯衬垫的 Avantage DM THA 骨水泥固定(30 人)或无骨水泥羟基磷灰石涂层固定(30 人)。髋臼杯移位和聚乙烯磨损情况通过放射性立体计量分析(RSA)进行测量,血清中的铬和钴离子进行测量,体力活动情况通过加速度计进行测量:随访6年时,骨水泥杯的近端移位相似:骨水泥杯为0.14毫米(95% CI 0.01-0.28),无骨水泥杯为0.21毫米(0.02-0.39)。1-6年随访期间的PE磨损率也相似:有骨水泥杯为0.06毫米/年(0.04-0.09),无骨水泥杯为0.07毫米/年(0.04-0.11)。血清中的金属离子水平检测不到或很低。体力活动主要是低强度的,与PE磨损率和杯移位无关:结论:使用高交联维生素E内衬的有骨水泥和无骨水泥DM髋臼杯在进行初级THA手术时具有相似的髋臼杯移位和PE磨损。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Orthopaedica
Acta Orthopaedica 医学-整形外科
CiteScore
6.40
自引率
8.10%
发文量
105
审稿时长
4-8 weeks
期刊介绍: Acta Orthopaedica (previously Acta Orthopaedica Scandinavica) presents original articles of basic research interest, as well as clinical studies in the field of orthopedics and related sub disciplines. Ever since the journal was founded in 1930, by a group of Scandinavian orthopedic surgeons, the journal has been published for an international audience. Acta Orthopaedica is owned by the Nordic Orthopaedic Federation and is the official publication of this federation.
期刊最新文献
Acute treatment of elderly patients with acetabular fractures by open reduction, internal fixation, and total hip arthroplasty: a 1-10-year follow-up of 48 patients. Incidence and risk factors of adverse events after distal radius fracture fixation with volar locking plates: retrospective analysis of 2,790 cases. The completeness of national hip and knee replacement registers. Can KOOS-PS be replaced with a simple anchor question in patients after total knee arthroplasty?: an agreement study of 2,478 primary surgeries. Erratum: Regional variation in low-value musculoskeletal surgery: a nationwide study from the Finnish Care Register.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1