Combination of ultrasound-guided percutaneous A1 pulley release and intra-tendon sheath injection improves the therapeutic outcomes in adult trigger finger patients.

IF 1.8 4区 医学 Q2 ACOUSTICS Medical Ultrasonography Pub Date : 2023-06-26 DOI:10.11152/mu-3877
Xingyou Zan, Wei-Ping Zhou, Yan Wang, Min Xu, Feng-Sheng Zhou, Xiang-Ming Fang
{"title":"Combination of ultrasound-guided percutaneous A1 pulley release and intra-tendon sheath injection improves the therapeutic outcomes in adult trigger finger patients.","authors":"Xingyou Zan,&nbsp;Wei-Ping Zhou,&nbsp;Yan Wang,&nbsp;Min Xu,&nbsp;Feng-Sheng Zhou,&nbsp;Xiang-Ming Fang","doi":"10.11152/mu-3877","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study aimed to use high-frequency ultrasound guidance to compare the efficacy of percutaneous release combined with intra-tendon sheath injection (PR-ITSI) and percutaneous release only (PR-ONLY) in the treatment of adult trigger finger (TF) patients.</p><p><strong>Materials and methods: </strong>A total of 48 patients were randomly divided into PR-ITSI group and PR-ONLY group. The thickness of the A1 pulley was measured prior to surgery and 1-year after surgery. Visual Analogue Scale (VAS) score and Patient Global Impression of Improvement (PGI-I) scale score of affected fingers were evaluated at 1 day, 1 month, and 1 year after surgery.</p><p><strong>Results: </strong>The overall difference of VAS score between the two groups after treatment was statistically significant (p<0.001), while the VAS scores gradually decreased in both groups at different time-points after treatment. The VAS scores in the PR-ITSI group at 1 day and 1 month after surgery were 1.475 and 0.904 (p<0.001), respectively, which were lower than those in the PR-ONLY group. Different treatment methods had no effect on the VAS score at 1 year after surgery (p=0.055). The thickness of the A1 pulley at 1 year after surgery was lower than that before surgery (p<0.001), whereas there was no significant difference in A1 pulley thickness between the two groups (p=0.095). The rate of PGI-I scale improvement by one grade at 1 day, 1 month, and 1 year after surgery in the PR-ITSI group was 15.322 times (95%CI: 4.466-52.573, p<0.001), 14.807 times (95%CI: 2.931-74.799, p=0.001), and 15.557 times (95%CI: 1.119-216.307, p=0.041), respectively, than that in the PR-ONLY group.</p><p><strong>Conclusion: </strong>Ultrasound-guided PR-ITSI is superior to PR-ONLY in the VAS score and PGI-I scale for adult TF patients.</p>","PeriodicalId":48781,"journal":{"name":"Medical Ultrasonography","volume":"25 2","pages":"153-160"},"PeriodicalIF":1.8000,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Ultrasonography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11152/mu-3877","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study aimed to use high-frequency ultrasound guidance to compare the efficacy of percutaneous release combined with intra-tendon sheath injection (PR-ITSI) and percutaneous release only (PR-ONLY) in the treatment of adult trigger finger (TF) patients.

Materials and methods: A total of 48 patients were randomly divided into PR-ITSI group and PR-ONLY group. The thickness of the A1 pulley was measured prior to surgery and 1-year after surgery. Visual Analogue Scale (VAS) score and Patient Global Impression of Improvement (PGI-I) scale score of affected fingers were evaluated at 1 day, 1 month, and 1 year after surgery.

Results: The overall difference of VAS score between the two groups after treatment was statistically significant (p<0.001), while the VAS scores gradually decreased in both groups at different time-points after treatment. The VAS scores in the PR-ITSI group at 1 day and 1 month after surgery were 1.475 and 0.904 (p<0.001), respectively, which were lower than those in the PR-ONLY group. Different treatment methods had no effect on the VAS score at 1 year after surgery (p=0.055). The thickness of the A1 pulley at 1 year after surgery was lower than that before surgery (p<0.001), whereas there was no significant difference in A1 pulley thickness between the two groups (p=0.095). The rate of PGI-I scale improvement by one grade at 1 day, 1 month, and 1 year after surgery in the PR-ITSI group was 15.322 times (95%CI: 4.466-52.573, p<0.001), 14.807 times (95%CI: 2.931-74.799, p=0.001), and 15.557 times (95%CI: 1.119-216.307, p=0.041), respectively, than that in the PR-ONLY group.

Conclusion: Ultrasound-guided PR-ITSI is superior to PR-ONLY in the VAS score and PGI-I scale for adult TF patients.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声引导下经皮A1滑轮松解联合肌腱鞘内注射可提高成人扳机指患者的治疗效果。
目的:本研究旨在利用高频超声引导,比较经皮释放联合肌腱鞘内注射(PR-ITSI)与单纯经皮释放(PR-ONLY)治疗成人扳机指(TF)的疗效。材料与方法:48例患者随机分为PR-ITSI组和PR-ONLY组。术前和术后1年测量A1滑轮的厚度。分别于术后1天、1个月和1年评估患指视觉模拟评分(VAS)评分和患者整体改善印象评分(PGI-I)。结果:两组治疗后VAS评分总体差异有统计学意义(p结论:超声引导下PR-ITSI在成人TF患者的VAS评分和PGI-I量表上均优于PR-ONLY。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Ultrasonography
Medical Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.20
自引率
5.90%
发文量
79
期刊介绍: The journal aims to promote ultrasound diagnosis by publishing papers in a variety of categories, including editorial letters, original papers, review articles, pictorial essays, technical developments, case reports, letters to the editor or occasional special reports (fundamental, clinical as well as methodological and educational papers). The papers published cover the whole spectrum of the applications of diagnostic medical ultrasonography, including basic science and therapeutic applications. The journal hosts information regarding the society''s activities, scheduling of accredited training courses in ultrasound diagnosis, as well as the agenda of national and international scientific events.
期刊最新文献
Comments and illustrations of the WFUMB CEUS liver guidelines: Rare benign focal liver lesion, part II. Comments and illustrations of the WFUMB CEUS liver guidelines: Rare benign focal liver lesion, part I. Comments on and illustrations of the WFUMB CEUS liver guidelines: Rare malignant neuroendocrine and predominant epithelioid liver lesions. Clinical application value of Ultrafast Pulse Wave Velocity in early cardiovascular injury of Immunoglobulin A nephropathy. Quantitative assessment of early kidney injury using high frame rate contrast-enhanced ultrasonography in a rabbit model of diabetic nephropathy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1