Urinary profiles of methoxyphenamine and its metabolite after inhalation of methoxyphenamine smoke in humans: aiming to distinguish between active and passive exposure.
{"title":"Urinary profiles of methoxyphenamine and its metabolite after inhalation of methoxyphenamine smoke in humans: aiming to distinguish between active and passive exposure.","authors":"Haruka Morinaka, Asuka Kaizaki-Mitsumoto, Hokuto Morohoshi, Naoki Uchida, Satoshi Numazawa","doi":"10.1007/s11419-022-00658-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Methamphetamine (METH) is commonly abused through smoking. However, the lack of evidence regarding differences in urinary METH excretion after its active and passive inhalation has resulted in complications where the accused claims passive exposure. This study aimed to determine the differences in urinary excretion after active and passive inhalation of the drug, using methoxyphenamine (MPA) as a model for METH.</p><p><strong>Methods: </strong>Body temperature and locomotor activity were measured in mice as indicators of central nervous system toxicity. Six healthy adult male subjects were exposed to passive or active inhalation of MPA smoke in a small room, and urine samples were taken. MPA concentrations were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS).</p><p><strong>Results: </strong>There were no signs of toxicity in mice exposed to MPA smoke, ensuring the safety of the clinical study. Urinary MPA concentrations were significantly lower with passive inhalation compared with those of active inhalation. The maximum urinary MPA concentration in passive inhalation was 13.4 ng/mL, which was 1/60 of active inhalation with 800 ng/mL. The urinary excretion in passive inhalation until 24 h was 8.21 μg, which was 1/76 of active inhalation with 625 μg.</p><p><strong>Conclusions: </strong>Since METH and MPA are expected to be excreted similarly, urinary METH concentrations in passively exposed persons are expected to be lower than the cutoff value of the screening kit. If the urine screening test is positive, the suspect should be considered a METH user.</p><p><strong>Trial registration number: </strong>jRCTs031210604, registration date: Feb. 9, 2022.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10310607/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-022-00658-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Methamphetamine (METH) is commonly abused through smoking. However, the lack of evidence regarding differences in urinary METH excretion after its active and passive inhalation has resulted in complications where the accused claims passive exposure. This study aimed to determine the differences in urinary excretion after active and passive inhalation of the drug, using methoxyphenamine (MPA) as a model for METH.
Methods: Body temperature and locomotor activity were measured in mice as indicators of central nervous system toxicity. Six healthy adult male subjects were exposed to passive or active inhalation of MPA smoke in a small room, and urine samples were taken. MPA concentrations were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS).
Results: There were no signs of toxicity in mice exposed to MPA smoke, ensuring the safety of the clinical study. Urinary MPA concentrations were significantly lower with passive inhalation compared with those of active inhalation. The maximum urinary MPA concentration in passive inhalation was 13.4 ng/mL, which was 1/60 of active inhalation with 800 ng/mL. The urinary excretion in passive inhalation until 24 h was 8.21 μg, which was 1/76 of active inhalation with 625 μg.
Conclusions: Since METH and MPA are expected to be excreted similarly, urinary METH concentrations in passively exposed persons are expected to be lower than the cutoff value of the screening kit. If the urine screening test is positive, the suspect should be considered a METH user.
期刊介绍:
The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published.
Forensic Toxicology is the official publication of the Japanese Association of Forensic Toxicology (JAFT) and is the continuation of the Japanese Journal of Forensic Toxicology (ISSN 0915-9606).